The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Laser speckle contrast imaging in biomedical optics
Open accessAbstract
First introduced in the 1980s, laser speckle contrast imaging is a powerful tool for full-field imaging of blood flow. Recently laser speckle contrast imaging has gained increased attention, in part due to its rapid adoption for blood flow studies in the brain. We review the underlying physics of speckle contrast imaging and discuss recent developments to improve the quantitative accuracy of blood flow measures. We also review applications of laser speckle contrast imaging in neuroscience, dermatology and ophthalmology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
(1985) · Springer eBooks · doi:10.1007/978-1-4613-2389-1 · Cited by 4,856
Goodman, J. W. (1985) · Cited by 4,004
Pathobiology of ischaemic stroke: an integrated view
Dirnagl, U., Iadecola, C., & Moskowitz, M. A. (1999) · Trends in Neurosciences · doi:10.1016/s0166-2236(99)01401-0 · Cited by 3,943
Interplay between Cortical Spreading Depolarization and Seizures
Kramer, D. R., Fujii, T., Ohiorhenuan, I., & Liu, C. Y. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000452841 · Cited by 3,696
SPREADING DEPRESSION OF ACTIVITY IN THE CEREBRAL CORTEX
Leao, A. A. P. (1944) · Journal of Neurophysiology · doi:10.1152/jn.1944.7.6.359 · Cited by 2,679
Statistical Properties of Laser Speckle Patterns
Goodman, J. W. (1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1_2 · Cited by 1,249
Functional architecture of cortex revealed by optical imaging of intrinsic signals
Grinvald, A., Lieke, E., Frostig, R. D., Gilbert, C. D., & Wiesel, T. N. (1986) · Nature · doi:10.1038/324361a0 · Cited by 1,244
Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model
Bolay, H., Reuter, U., Dunn, A. K., Huang, Z., Boas, D. A., & Moskowitz, M. A. (2002) · Nature Medicine · doi:10.1038/nm0202-136 · Cited by 1,214
Self-citationPine, D. J., Weitz, D. A., Chaikin, P. M., & Herbolzheimer, E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1134 · Cited by 1,162
Pathophysiology of the migraine aura: The spreading depression theory
Lauritzen, M. (1994) · Brain · doi:10.1093/brain/117.1.199 · Cited by 1,151
Mechanisms of Spreading Depression and Hypoxic Spreading Depression-Like Depolarization
Somjen, G. G. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.3.1065 · Cited by 1,124
FURTHER OBSERVATIONS ON THE SPREADING DEPRESSION OF ACTIVITY IN THE CEREBRAL CORTEX
Leo, A. A. P. (1947) · Journal of Neurophysiology · doi:10.1152/jn.1947.10.6.409 · Cited by 943
In vivo evaluation of microcirculation by coherent light scattering
STERN, M. D. (1975) · Nature · doi:10.1038/254056a0 · Cited by 857
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826
Self-citationBriers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686
Flow visualization by means of single-exposure speckle photography
Fercher, A. F., & Briers, J. D. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90428-4 · Cited by 670
Dreier, J. P., Woitzik, J., Fabricius, M., Bhatia, R., Major, S., Drenckhahn, C., Lehmann, T.-N., Sarrafzadeh, A., Willumsen, L., Hartings, J. A., et al. (2006) · Brain · doi:10.1093/brain/awl297 · Cited by 562
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Laser Doppler perfusion imaging by dynamic light scattering
Wardell, K., Jakobsson, A., & Nilsson, G. E. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.222322 · Cited by 435
Fabricius, M., Fuhr, S., Bhatia, R., Boutelle, M., Hashemi, P., Strong, A. J., & Lauritzen, M. (2006) · Brain · doi:10.1093/brain/awh716 · Cited by 420
Correlation between periinfarct DC shifts and ischaemic neuronal damage in rat
Mies, G., lijima, T., & Hossmann, K.-A. (1993) · NeuroReport · doi:10.1097/00001756-199306000-00027 · Cited by 404
Robust flow measurement with multi-exposure speckle imaging
Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K. (2008) · Optics Express · doi:10.1364/oe.16.001975 · Cited by 367
Self-citationLaser Doppler measurements of blood flow in capillary tubes and retinal arteries.
Riva, C. E., Ross, B., & Benedek, G. B. (1972) · PubMed · Cited by 362
Dunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Self-citationVasoconstrictive Neurovascular Coupling during Focal Ischemic Depolarizations
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Moskowitz, M. A., & Ayata, C. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600252 · Cited by 320
Self-citationDunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Self-citationModified laser speckle imaging method with improved spatial resolution
Cheng, H., Luo, Q., Zeng, S., Chen, S., Cen, J., & Gong, H. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1578089 · Cited by 256
A laser Doppler scanner for imaging blood flow in skin
Essex, T. J. H., & Byrne, P. O. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90125-q · Cited by 256
Retinal blood-flow visualization by means of laser speckle photography.
Briers, J. D., & FERCHER, A. F. (1982) · PubMed · Cited by 233
Yuan, S., Devor, A., Boas, D. A., et al. (2005) · Applied Optics · doi:10.1364/ao.44.001823 · Cited by 222
Self-citationCan laser speckle flowmetry be made a quantitative tool?
Duncan, D. D., & Kirkpatrick, S. J. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.002088 · Cited by 219
Peri-infarct depolarizations lead to loss of perfusion in ischaemic gyrencephalic cerebral cortex
Strong, A. J., Anderson, P. J., Watts, H. R., Virley, D. J., Lloyd, A., Irving, E. A., Nagafuji, T., Ninomiya, M., Nakamura, H., Dunn, A. K., et al. (2006) · Brain · doi:10.1093/brain/awl392 · Cited by 212
Self-citationDevor, A., Hillman, E. M. C., Tian, P., Waeber, C., Teng, I. C., Ruvinskaya, L., Shalinsky, M. H., Zhu, H., Haslinger, R. H., Narayanan, S. N., et al. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4307-08.2008 · Cited by 206
Self-citationPronounced Hypoperfusion during Spreading Depression in Mouse Cortex
Ayata, C., Shin, H. K., Salomone, S., Ozdemir-Gursoy, Y., Boas, D. A., Dunn, A. K., & Moskowitz, M. A. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000137057.92786.f3 · Cited by 194
Self-citationZhang, S., & Murphy, T. H. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050119 · Cited by 193
Masino, S. A., Kwon, M. C., Dory, Y., & Frostig, R. D. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9998 · Cited by 187
Durduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200405000-00005 · Cited by 168
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Lo, E. H., Moskowitz, M. A., & Ayata, C. (2007) · Brain · doi:10.1093/brain/awm071 · Cited by 163
Self-citationMayhew, J. E., Johnston, D. K., Berwick, J., Jones, M., Coffey, P. J., & Zheng, Y. (2000) · NeuroImage · doi:10.1006/nimg.2000.0656 · Cited by 156
Jones, P., Shin, H. K., Boas, D. A., Hyman, B. T., Moskowitz, M. A., Ayata, C., & Dunn, A. K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2950312 · Cited by 123
Self-citationKoseki, N., Araie, M., Tomidokoro, A., Nagahara, M., Hasegawa, T., Tamaki, Y., & Yamamoto, S. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.05.015 · Cited by 110
Weber, B., Burger, C., Wyss, M. T., von Schulthess, G. K., Scheffold, F., & Buck, A. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03735.x · Cited by 109
Strong, A. J., Bezzina, E. L., Anderson, P. J., Boutelle, M. G., Hopwood, S. E., & Dunn, A. K. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600240 · Cited by 86
Self-citationNew Laser Speckle Flowgraphy System Using CCD Camera
Konishi, N., Tokimoto, Y., Kohra, K., & Fujii, H. (2002) · Optical Review · doi:10.1007/s10043-002-0163-4 · Cited by 85
Quantitative long-term imaging of the functional representation of a whisker in rat barrel cortex.
Masino, S. A., & Frostig, R. D. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.10.4942 · Cited by 82
Efficient Processing of Laser Speckle Contrast Images
Tom, W. J., Ponticorvo, A., & Dunn, A. K. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925081 · Cited by 79
Self-citationAnces, B. M., Wilson, D. F., Greenberg, J. H., & Detre, J. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200105000-00005 · Cited by 72
Sakadžić, S., Yuan, S., Dileköz, E., Ruvinskaya, S., Vinogradov, S. A., Ayata, C., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d169 · Cited by 65
Self-citationMouse Model of Microembolic Stroke and Reperfusion
Atochin, D. N., Murciano, J.-C., Özdemir, Y., et al. (2004) · Stroke · doi:10.1161/01.str.0000137412.35700.0e · Cited by 62
Obrenovitch, T. P., Chen, S., & Farkas, E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.11.025 · Cited by 51
(2000) · Medical radiology · doi:10.1007/978-3-642-58716-0 · Cited by 46
Research works printed but not linked: 28
- H. Cummins and H. L. Swinney , “Light beating spectroscopy,” in Progress in Optics , E. Wolf , Ed., Vol. VIII, p. 133, North Holland Publishing Co., Amsterdam (1970). · DOI
- 10.1146/annurev.bb.01.060172.001353 · doi:10.1146/annurev.bb.01.060172.001353
- Riva, 1972, Invest. Ophthalmol., 11, 936
- P. J. Berne and R. Pecora , Dynamic Light Scattering , Wiley, New York (1976).
- 10.1063/1.2037987 · doi:10.1063/1.2037987
- S. Yuan , “Sensitivity, noise and quantitative model of laser speckle contrast imaging,” PhD thesis, Tufts University, Medford, MA (2008).
- 10.1364/OL.31.001824 · doi:10.1364/ol.31.001824
- 10.1364/OL.33.002886 · doi:10.1364/ol.33.002886
- 10.1364/JOSAA.25.000009 · doi:10.1364/josaa.25.000009
- 10.1364/OE.16.014321 · doi:10.1364/oe.16.014321
- 10.1364/OL.34.001480 · doi:10.1364/ol.34.001480
- 10.1109/TBME.2004.834259 · doi:10.1109/tbme.2004.834259
- 10.1364/OE.16.003197 · doi:10.1364/oe.16.003197
- 10.1364/JOSAA.16.001651 · doi:10.1364/josaa.16.001651
- 10.1103/PhysRevA.44.5215 · doi:10.1103/physreva.44.5215
- 10.1364/OE.16.010214 · doi:10.1364/oe.16.010214
- 10.1364/OL.31.003465 · doi:10.1364/ol.31.003465
- 10.1109/TMI.2007.892643 · doi:10.1109/tmi.2007.892643
- Briers, 1982, Invest. Ophthalmol. Visual Sci., 22, 255
- Tamaki, 1994, Invest. Ophthalmol. Visual Sci., 35, 3825
- 10.1016/j.mvr.2004.04.003 · doi:10.1016/j.mvr.2004.04.003
- 10.1117/1.2341196 · doi:10.1117/1.2341196
- 10.1002/lsm.20619 · doi:10.1002/lsm.20619
- 10.1016/S0014-4835(05)80094-6 · doi:10.1016/s0014-4835(05)80094-6
- Sugiyama, 2009, Arch. Ophthalmol. (Chicago), 127, 454, 10.1001/archophthalmol.2008.606 · doi:10.1001/archophthalmol.2008.606
- 10.1016/S0002-9394(00)00382-2 · doi:10.1016/s0002-9394(00)00382-2
- Isono, 2003, Arch. Ophthalmol. (Chicago), 121, 225, 10.1001/archopht.121.2.225 · doi:10.1001/archopht.121.2.225
- 10.1006/nimg.2001.0753 · doi:10.1006/nimg.2001.0753
Cited by
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Recent progress in tissue optical clearing
Zhu, D., Larin, K. V., Luo, Q., & Tuchin, V. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200056 · Cited by 394
Methods and algorithms for optical coherence tomography-based angiography: a review and comparison
Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.100901 · Cited by 371
Metadata
- Authors
- Boas, D. A., & Dunn, A. K.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2010
- Volume
- 15
- Issue
- 1
- Pages
- 011109
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2147182902
- Cited by
- 1,122
- References
- 52
- FWCI
- 37.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.