Review of fiber-optic pressure sensors for biomedical and biomechanical applications
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
As optical fibers revolutionize the way data is carried in telecommunications, the same is happening in the world of sensing. Fiber-optic sensors (FOS) rely on the principle of changing the properties of light that propagate in the fiber due to the effect of a specific physical or chemical parameter. We demonstrate the potentialities of this sensing concept to assess pressure in biomedical and biomechanical applications. FOSs are introduced after an overview of conventional sensors that are being used in the field. Pointing out their limitations, particularly as minimally invasive sensors, is also the starting point to argue FOSs are an alternative or a substitution technology. Even so, this technology will be more or less effective depending on the efforts to present more affordable turnkey solutions and peer-reviewed papers reporting in vivo experiments and clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photosensitivity in optical fiber waveguides: Application to reflection filter fabrication
Hill, K. O., Fujii, Y., Johnson, D. C., & Kawasaki, B. S. (1978) · Applied Physics Letters · doi:10.1063/1.89881 · Cited by 2,250
Formation of Bragg gratings in optical fibers by a transverse holographic method
Meltz, G., Morey, W. W., & Glenn, W. H. (1989) · Optics Letters · doi:10.1364/ol.14.000823 · Cited by 1,808 · cited 2×
“The first one in 1978 was the discovery of Journal of Biomedical Optics 050903-3 May 2013 • Vol. 18(5) Downloaded From: https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics on 20 May 2022 Terms of Use: https://www.spiedigitallibrary.org/terms-of-use photosensitivity in OF by Hill et al.49,50 In 198…”
MethodFiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
New In Vivo Measurements of Pressures in the Intervertebral Disc in Daily Life
Wilke, H., Neef, P., Caimi, M., Hoogland, T., & Claes, L. E. (1999) · Spine · doi:10.1097/00007632-199904150-00005 · Cited by 1,498
Othonos, A. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148392 · Cited by 1,332
Continuous Recording and Control of Ventricular Fluid Pressure in Neurosurgical Practice
Lundberg, N. (1962) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-196207000-00018 · Cited by 1,089
Fiber Optic Sensors: An Introduction for Engineers and Scientists
(2011) · Wiley eBooks · doi:10.1002/9781118014103 · Cited by 783
A review of fiber-optic biosensors
Leung, A., Shankar, P. M., & Mutharasan, R. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.03.010 · Cited by 693 · cited 1×
“e x v iv o hu m an [1 76 – 18 0]”
Journal of Magnetic Resonance Imaging
(2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/(issn)1522-2586 · Cited by 666
Magnetic Resonance in Medicine
(2006) · Magnetic Resonance in Medicine · doi:10.1002/(issn)1522-2594 · Cited by 663
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., Recum, H. V., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 558 · cited 1×
“This compound is almost chemically inert and biocompatible.(4) Only hydro-”
Background(2002) · CRC Press eBooks · doi:10.1201/9780824744571 · Cited by 510
NACHEMSON, A. L., & Morris, J. M. (1964) · PubMed · Cited by 501
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443 · cited 1×
“high-temperature-resistant polymers are Teflon/PTFE (230°C), polyimide (220°C), and silicone rubber (200°C).(16)”
BackgroundQuadrature phase-shifted, extrinsic Fabry–Perot optical fiber sensors
Murphy, K. A., Gunther, M. F., Vengsarkar, A. M., & Claus, R. O. (1991) · Optics Letters · doi:10.1364/ol.16.000273 · Cited by 421 · cited 1×
“The sensor consisted of an extrinsic F-P air cavity in-between a polished end fiber and a reflective membrane.(93,163) It was calibrated inside an air-pressure chamber under slowly dynamic pressures ranging from 0 to 250 mmHg back to 0 mmHg, over a period of 120 s.”
MethodIntracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B. (2012) · Critical Care Research and Practice · doi:10.1155/2012/950393 · Cited by 416
Continuous Recording and Control of Ventricular Fluid Pressure in Neurosurgical Practice
WALKER, A. E. (1962) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-196204000-00015 · Cited by 405
Fiber Optic Sensors: An Introduction for Engineers and Scientists
Omar, A. (2013) · Sensor Review · doi:10.1108/sr.2013.08733baa.010 · Cited by 379
A Flexible Fibrescope, using Static Scanning
HOPKINS, H. H., & KAPANY, N. S. (1954) · Nature · doi:10.1038/173039b0 · Cited by 370
Intramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355 · cited 2×
“IMP is directly correlated with the force output of the muscle.(158,159) Therefore, by measuring IMP, the contribution of an individual muscle group to the force measured over a joint can be assessed.”
BackgroundMicrofabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344 · cited 2×
“and Voldman et al.(63) The Neurovent microchip SG catheter (Raumedic AG, Münchberg, Germany; www.”
BackgroundFiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2002) · Analytical Chemistry · doi:10.1021/ac020176e · Cited by 325
Fiber-Optic Sensors for Biomedical Applications
Peterson, J. I., & Vurek, G. G. (1984) · Science · doi:10.1126/science.6422554 · Cited by 300
Monitoring Intracranial Pressure in Traumatic Brain Injury
Smith, M. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297296.52006.8e · Cited by 294 · cited 1×
“This is not satisfactory because normal values for ICP usually range from 7 to 15 mmHg in adults and from 3 to 7 mmHg in children.(109) Furthermore, values exceeding 20 mmHg require immediate treatment.”
BackgroundRecent Development in Optical Fiber Biosensors
Bosch, M. E., Sánchez, A. J. R., Rojas, F. S., & Ojeda, C. B. (2007) · Sensors · doi:10.3390/s7060797 · Cited by 287
Fiber grating sensors in medicine: Current and emerging applications
Mishra, V., Singh, N., Tiwari, U., & Kapur, P. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.02.045 · Cited by 275
(2006) · doi:10.1002/(issn)1365-2168 · Cited by 246
Measurement of blast wave by a miniature fiber optic pressure transducer in the rat brain
Chavko, M., Koller, W. A., Prusaczyk, W. K., & McCarron, R. M. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.07.018 · Cited by 232 · cited 2×
“The F-P cavity is connected to a MMF and interrogated with white light.(142,144) According to manufacturers’ specifications, FOP-MIV exhibits a measurement range from −300 to 300 mmHg, an accuracy equal to 1.”
MethodIn-fiber Bragg-grating temperature sensor system for medical applications
Rao, Y.-J., Webb, D. J., Jackson, D. A., Zhang, L., & Bennion, I. (1997) · Journal of Lightwave Technology · doi:10.1109/50.580812 · Cited by 221 · cited 1×
“Additionally, multiplexing will also contribute to reduce the cost per sensor and of the whole system making FBG competitive with conventional sensors.(58) Compared with conventional sensors, namely the foil SG, FBG sensors are capable of providing absolute strain measurements with easier instrumentation.”
BackgroundPolla, D. L., Erdman, A. G., Robbins, W. P., Markus, D. T., Diaz-Diaz, J., Rizq, R., Nam, Y., Brickner, H. T., Wang, A., & Krulevitch, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.551 · Cited by 220 · cited 2×
“The most promising are microelectromechanical systems, which technology, along with examples and applications, is well described in the work of Polla et al.62 and Voldman et al.63 The Neurovent microchip SG catheter (Raumedic AG, Münchberg, Germany; www.raumedic.com) is a good example of a commercially available solut…”
MethodImplanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Scholander, P. F., Hargens, A. R., & Miller, S. L. (1968) · Science · doi:10.1126/science.161.3839.321 · Cited by 197
Davis, J., Kaufman, K. R., & Lieber, R. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00430-x · Cited by 186
The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases
Gelabert-González, M., Ginesta-Galan, V., Sernamito-García, R., Allut, A. G., Bandin-Diéguez, J., & Rumbo, R. M. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0683-3 · Cited by 163
All-fiber high-sensitivity pressure sensor with SiO_2 diaphragm
Đonlagić, D., & Cibula, E. (2005) · Optics Letters · doi:10.1364/ol.30.002071 · Cited by 156 · cited 1×
“An all-fused-silica design, based on the replacement of the polymer diaphragm by a silica one, was also proposed.(153) This approach changed resolution to 300 Pa.”
MethodJournal of Orthopaedic Research®
(2006) · Journal of Orthopaedic Research® · doi:10.1002/(issn)1554-527x · Cited by 143
Miller, R. G., & Nora, L. M. (2006) · Muscle & Nerve · doi:10.1002/(issn)1097-4598 · Cited by 140
Evaluation of a fiberoptic intracranial pressure monitor
Crutchfield, J. S., Narayan, R. K., ROBERTSON, C. S., & Michael, L. H. (1990) · Journal of neurosurgery · doi:10.3171/jns.1990.72.3.0482 · Cited by 124 · cited 5×
“As an example, Crutchfield et al.101 found a larger maximum daily drift of 2.5 mmHg, a lesser average daily drift of 0.6 mmHg and an average drift over a five-day period of 2.1 mmHg. Münch et al.105 reported an average daily drift within reference values but after being removed from the patient it was 3.2 17.2 mmHg fo…”
BackgroundMethodInfluentialCamino(R) intracranial pressure monitor: prospective study of accuracy and complications
Martínez-Mañas, R. (2000) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.69.1.82 · Cited by 113
Intracranial Pressure Increases during Exposure to a Shock Wave
Leonardi, A. D. C., BIR, C. A., Ritzel, D. V., & VandeVord, P. J. (2010) · Journal of Neurotrauma · doi:10.1089/neu.2010.1324 · Cited by 112 · cited 1×
“However, to our best knowledge, ICP measurements with the FOP-MIV were made only in rats.(144,145) Both OPP-M250 (0.”
MethodA fibre optic Bragg grating strain sensor for monitoring ventilatory movements
Wehrle, G., Nohama, P., Kalinowski, H. J., Torres, P., & Valente, L. C. G. (2001) · Measurement Science and Technology · doi:10.1088/0957-0233/12/7/309 · Cited by 111 · cited 1×
“in v iv o ; do g [1 24 ]”
Biomedical sensors using optical fibres
Mignani, A. G., & Baldini, F. (1996) · Reports on Progress in Physics · doi:10.1088/0034-4885/59/1/001 · Cited by 110 · cited 9×
“(e x v iv o ) [2 7, 17 1]”
InfluentialLaboratory Testing of Three Intracranical Pressure Microtransducers: Technical Report
Czosnyka, M., Czosnyka, Z. H., Pickard, J. D., & Chir, M. (1996) · Neurosurgery · doi:10.1097/00006123-199601000-00053 · Cited by 108 · cited 4×
“However, in the study of Czosnyka et al.(104) temperature drift was ∼0.”
BackgroundInfluentialArkwright, J. W., Blenman, N. G., Underhill, I. D., Maunder, S. A., Szczesniak, M. M., Dinning, P. G., & Cook, I. J. (2009) · Optics Express · doi:10.1364/oe.17.004500 · Cited by 96 · cited 4×
“, a temperature profile along a tissue), but only at the expense of increased dimensions and loss of flexibility.(2) These disadvantages combined with poor biocompatibility of metallic components and large sensitivity to electromagnetic interference (EMI) can compromise some in vivo applications and their use in clini…”
BackgroundMethodInfluentialPiper, I., Barnes, A., Smith, D. C., & Dunn, L. (2001) · Neurosurgery · doi:10.1097/00006123-200111000-00026 · Cited by 89 · cited 4×
“) may range from 10% to 25%.(107) In the study of Yablon et al.”
BackgroundInfluentialThe first surface micromachined pressure sensor for cardiovascular pressure measurements
Kälvesten, E., Smith, L., Tenerz, L., & Stemme, G. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1998.659821 · Cited by 88
Münch, E., Weigel, R., Schmiedek, P., & Schürer, L. (1998) · Acta Neurochirurgica · doi:10.1007/s007010050224 · Cited by 84
Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies
Ravary‐Plumioën, B., Pourcelot, P., Bortolussi, C., Konieczka, S., & Crevier‐Denoix, N. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.01.008 · Cited by 73
Guehring, T., Unglaub, F., Lorenz, H., et al. (2005) · European Spine Journal · doi:10.1007/s00586-005-0953-z · Cited by 71
Thermal Stability of Specialty Optical Fibers
Stolov, A. A., Simoff, D. A., & Li, J. (2008) · Journal of Lightwave Technology · doi:10.1109/jlt.2008.925698 · Cited by 70 · cited 1×
“requiring heating procedures because it cannot withstand temperatures above 85°C.(14) Some manufacturers, such as”
BackgroundIn vivo studies with an intravascular and intracardiac reflection oximeter
Enson, Y., Briscoe, W. A., Polanyi, M. L., & Cournand, A. (1962) · Journal of Applied Physiology · doi:10.1152/jappl.1962.17.3.552 · Cited by 68
Transducers for foot pressure measurement: survey of recent developments
Cobb, J., & Claremont, D. J. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522509 · Cited by 66
Quantitative measurement of muscle fiber composition in a normal population
Toft, I., Lindal, S., Bønaa, K. H., & Jenssen, T. (2003) · Muscle & Nerve · doi:10.1002/mus.10373 · Cited by 63 · cited 1×
“Even so, a too large diameter compared with muscle fibers diameters (between 57 and 73 μm).(162) The sensor consisted of an extrinsic F-P air cavity in-between a polished end fiber and a reflective membrane.”
BackgroundFBG-based smart bed system for healthcare applications
Hao, J., Jayachandran, M., Kng, P. L., Foo, S. F., Wai, A. A. P., & Cai, Z. (2010) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0066-0 · Cited by 61 · cited 3×
“Temperature sensor consisted of a FBG (10 mm length) isolated from strain by insertion into a glass/copper tube, which ends were encapsulated with a resin/epoxy system.(211) Pressure mats are often used in biomechanical studies; namely, to analyze foot pressure distribution in static postures or dynamic activities, su…”
BackgroundMethodInfluentialFiber grating sensor for pressure mapping during total knee arthroplasty
Mohanty, L., Tjin, S. C., Lie, D. T. T., Panganiban, S. E. C., & Chow, P. K. H. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.07.021 · Cited by 55 · cited 5×
“Embedding is important to enhance FBG sensitivity to transverse loading.(27,57,172) Each OF was composed of sampled chirped FBG sensors capable of detecting force magnitude and its application point.”
BackgroundMethodInfluentialEide, P. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.01.005 · Cited by 48
den Uil, C. A., Lagrand, W. K., van der Ent, M., Jewbali, L. S. D., Brugts, J. J., Spronk, P. E., & Simoons, M. L. (2009) · Cardiology · doi:10.1159/000212060 · Cited by 46 · cited 1×
“commercializes the FiberOptixTM IAB Catheter, used in clinical practice to monitor arterial pressure.(139,149) MAQUET Getinge Group is commercializing two IAB catheters (Sensation PlusTM 8Fr.”
MethodA comparison of extradural and intraparenchymatous intracranial pressures in head injured patients
Bruder, N. J., N’zoghe, P., Graziani, N., Pellissier, D., Grisoli, F., & François, G. (1995) · Intensive Care Medicine · doi:10.1007/bf01700971 · Cited by 44
Zhou, M.-D., Yang, C. C., Liu, Z., Cysyk, J. P., & Zheng, S.-Y. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9601-z · Cited by 40 · cited 3×
“In this case, however, authors have pointed the necessary steps to accomplish it.(141) Several companies, such as FISO Technologies (Québec, Canada), Arrow International, Inc.”
BackgroundMethodInfluentialOptical-Fiber Measurement Systems for Medical Applications
Silvestri, S., & Sche, E. (2011) · InTech eBooks · doi:10.5772/18845 · Cited by 38
In-vivo biomedical monitoring by fiber-optic systems
Mignani, A. G., & Baldini, F. (1995) · Journal of Lightwave Technology · doi:10.1109/50.400704 · Cited by 34 · cited 2×
“The American National Standard for ICP monitoring, published by the AAMI,196,197 includes minimum performance requirements that are clearly less demanding than those of Mignani and Baldini.71 Pressure should range between 1 and 100 mmHg, the accuracy of 2 mmHg in the range of 0 to 20 mmHg, and maximum error of 10% in…”
BackgroundInfluentialRole of load history in intervertebral disc mechanics and intradiscal pressure generation
Hwang, D., Gabai, A. S., Yu, M., Yew, A. G., & Hsieh, A. H. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0295-1 · Cited by 34
Biocompatibility of a physiological pressure sensor
Yang, C., Zhao, C., Wold, L. E., & Kaufman, K. R. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00131-3 · Cited by 33 · cited 1×
“Following functional characterization, the sensor was evaluated for biocompatibility using ISO standard 109936:2007 (Tests for Local Effects After Implantation).(165) In vivo experiments took place to measure IMP in the tibialis anterior muscle of anesthetized rabbits(166) and swine intra-myocardial pressure.”
MethodMeasuring interstitial fluid pressure with fiberoptic pressure transducers
Özerdem, U. (2008) · Microvascular Research · doi:10.1016/j.mvr.2008.08.002 · Cited by 32
Design of a foot-pressure monitoring transducer for diabetic patients based on FBG sensors
Hao, J. Z., Tan, K. M., Tjin, S. C., Liaw, C. Y., Chaudhuri, P. R., Guo, X., & Lü, C. (2004) · IEEE Lasers and Electro-Optics Society Annual Meeting (LEOS) · doi:10.1109/leos.2003.1251581 · Cited by 31 · cited 3×
“More recently, OF and FBG sensors were also introduced to sense foot pressure.(57,216) Multiplexed FBG arrays were positioned accordingly to the foot anatomy, embedded into uneven layers of carbon/epoxy laminates and cut into a shape of a footpad.”
MethodWolthuis, R. A., Mitchell, G. L., Hartl, J. C., & Saaski, E. W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.216415 · Cited by 24 · cited 3×
“The system was also low cost and easy to fabricate.88 Wolthuis et al.140 also have proposed a dual-function sensor system for simultaneous measurement of pressure and temperature.”
BackgroundInfluentialInvestigating the Effect of Ciliary Body Photodynamic Therapy in a Glaucoma Mouse Model
Matsubara, A., Nakazawa, T., Husain, D., Iliaki, E. F., Connolly, E., Michaud, N. A., Gragoudas, E. S., & Miller, J. W. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0959 · Cited by 23
Optoelectronic transducer for intravascular measurements of pressure variations
Lekholm, A., & Lindström, L. (1969) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474776 · Cited by 22
In vivo probes: Problems and perspectives
Thompson, M. E., & Vandenberg, E. T. (1986) · Clinical Biochemistry · doi:10.1016/s0009-9120(86)80037-6 · Cited by 22
Arkwright, J. W., Blenman, N. G., Underhill, I. D., Maunder, S. A., Spencer, N. J., Costa, M., Brookes, S. J., Szczesniak, M. M., & Dinning, P. G. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000056 · Cited by 22 · cited 1×
“Meanwhile, further studies have been published confirming FBG potentialities as multipoint or multiparameter sensors,(202,205) and their ability to incorporate new features, such as the measurement of longitudinal and circumferential muscular activity in the gastrointestinal tract.(202) An interesting example of the v…”
BackgroundA new technique for monitoring epidural intracranial pressure.
Wald, A., Post, K., Ransohoff, J., Hass, W. K., & Epstein, F. J. (1977) · PubMed · Cited by 18
An optic pharyngeal manometric sensor for deglutition analysis
Takeuchi, S., Tohara, H., Kudo, H., Otsuka, K., Saito, H., Uematsu, H., & Mitsubayashi, K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9103-1 · Cited by 16 · cited 2×
“A human in vivo application was reported for deglutition analysis assessed by measurement of pharyngeal pressure.(148) Arrow International Inc.”
BackgroundMethodYeomanson, C. W., & Evans, D. (1983) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/4/4/007 · Cited by 14
Cited by
Fiber Bragg grating sensors for monitoring of physical parameters: a comprehensive review
Sahota, J. K., Gupta, N., & Dhawan, D. (2020) · Optical Engineering · doi:10.1117/1.oe.59.6.060901 · Cited by 522
Biomedical application of optical fibre sensors
Correia, R., James, S., Lee, S.-W., Morgan, S. P., & Korposh, S. (2018) · Journal of Optics · doi:10.1088/2040-8986/aac68d · Cited by 206
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Metadata
- Authors
- Roriz, P., Frazão, O., Lobo-Ribeiro, A. B., Santos, J. L., & Simões, J. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-05-30
- Volume
- 18
- Issue
- 5
- Pages
- 050903
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2107088573
- Cited by
- 221
- References
- 73
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.