Polarized light imaging in biomedicine: emerging Mueller matrix methodologies for bulk tissue assessment
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Polarized light point measurements and wide-field imaging have been studied for many years in an effort to develop accurate and information-rich tissue diagnostic methods. However, the extensive depolarization of polarized light in thick biological tissues has limited the success of these investigations. Recently, advances in technology and conceptual understanding have led to a significant resurgence of research activity in the promising field of bulk tissue polarimetry. In particular, with the advent of improved measurement, analysis, and interpretation methods, including Mueller matrix decomposition, new diagnostic avenues, such as quantification of microstructural anisotropy in bulk tissues, have been enabled. Further, novel technologies have improved the speed and the accuracy of polarimetric instruments for ex vivo and in vivo diagnostics. In this paper, we review some of the recent progress in tissue polarimetry, provide illustrative application examples, and offer an outlook to the future of polarized light imaging in bulk biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409 · cited 3×
“Polar decomposition is sequential, meaning that it models tissue as a sequence of a depolarization, retardance, and diattentuation.(16) Perhaps somewhat surprisingly, this assumption works for tissues and model turbid media, as recently validated.”
BackgroundMethodCampagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Imaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582
Carbocyanine dye orientation in red cell membrane studied by microscopic fluorescence polarization
Axelrod, D. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85271-6 · Cited by 528
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., & Tromberg, B. J. (2005) · Optics Letters · doi:10.1364/ol.30.001354 · Cited by 429
Demos, S. G., & Alfano, R. R. (1997) · Applied Optics · doi:10.1364/ao.36.000150 · Cited by 404
Backman, V., Gurjar, R., Badizadegan, K., Itzkan, I., Dasari, R. R., Perelman, L. T., & Feld, M. S. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796325 · Cited by 396
Compain, E., Poirier, S., & Drevillon, B. (1999) · Applied Optics · doi:10.1364/ao.38.003490 · Cited by 369
Tyo, J. S. (2002) · Applied Optics · doi:10.1364/ao.41.000619 · Cited by 347
Cited by
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
He, H., Liao, R., Zeng, N., Li, P., Chen, Z., Liu, X., & Ma, H. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2868845 · Cited by 204
“scattering imaging of bulk tissue samples and transmission imaging of thin tissue slices [9], [10].”
Background
Metadata
- Authors
- Alali, S., & Vitkin, A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2015-03-20
- Volume
- 20
- Issue
- 6
- Pages
- 061104
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2114760570
- Cited by
- 267
- References
- 60
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.