New frontiers in time-domain diffuse optics, a review
Open accessThe DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
Abstract
The recent developments in time-domain diffuse optics that rely on physical concepts (e.g., time-gating and null distance) and advanced photonic components (e.g., vertical cavity source-emitting laser as light sources, single photon avalanche diode, and silicon photomultipliers as detectors, fast-gating circuits, and time-to-digital converters for acquisition) are focused. This study shows how these tools could lead on one hand to compact and wearable time-domain devices for point-of-care diagnostics down to the consumer level and on the other hand to powerful systems with exceptional depth penetration and sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light
Born, M., Wolf, E., & Hecht, E. (2000) · Physics Today · doi:10.1063/1.1325200 · Cited by 4,078 · cited 1×
“Conversely, when the optical etendue 93 of the detector is much higher than the one of the detection fibers, detection fibers need a large core and large NA in order to maximize light harvesting.”
BackgroundJöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · cited 1×
“However, the noticeable advances in technology, which have allowed the development of wearable devices or of complex multichannel and multiwavelength instruments, have always been based on physical models that rely on the measurement of light attenuation, like in the very first example of application of NIRS technolog…”
BackgroundTime-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002 · cited 2×
“These tools have been already developed for the CW domain.(76) Still, wearable TD devices could provide more robust signals because of the higher tolerance to moving artifacts and superficial effects, the larger independence from background signal, and the possibility to get information out of a single optode by hosti…”
BackgroundSingle-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726 · cited 1×
“On the other hand, solid-state detectors like SPADs are not affected by previous disadvantages, but up to now, they have rarely been the first choice for TD diffuse optics systems due to their small active area diameter of few hundreds of micrometers in the best case.(100,101) Devices with an active area diameter up t…”
BackgroundDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161 · cited 3×
“The study of photon propagation in highly scattering media (diffuse optics) is a powerful tool to noninvasively investigate biological tissues in depth.(1,2) For most biological media in the”
BackgroundAvalanche photodiodes and quenching circuits for single-photon detection
Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996) · Applied Optics · doi:10.1364/ao.35.001956 · Cited by 1,114 · cited 2×
“On the other hand, solid-state detectors like SPADs are not affected by previous disadvantages, but up to now, they have rarely been the first choice for TD diffuse optics systems due to their small active area diameter of few hundreds of micrometers in the best case.(100,101) Devices with an active area diameter up t…”
BackgroundRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114 · cited 1×
“comparison among the different modalities can be found elsewhere.(1,11,12) On the occasion of the 20th anniversary of the foundation of the Journal of Biomedical Optics—the first”
Background
Cited by
Pinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Broadband (550–1350 nm) diffuse optical characterization of thyroid chromophores
Konugolu Venkata Sekar, S., Farina, A., Dalla Mora, A., Lindner, C., Pagliazzi, M., Mora, M., Aranda, G., Dehghani, H., Durduran, T., Taroni, P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-27684-8 · Cited by 549
Self-citationGrassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“220 223 These systems, already tested in the human forearm, utilize new fast detectors for extreme depth penetration and sensitivity.”
BackgroundFunctional Near Infrared Spectroscopy: Enabling routine functional brain imaging
Yücel, M. A., Selb, J. J., Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.011 · Cited by 222
Diffuse optical characterization of collagen absorption from 500 to 1700 nm
Sekar, S. K. V., Bargigia, I., Mora, A. D., Taroni, P., Ruggeri, A., Tosi, A., Pifferi, A., & Farina, A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.1.015006 · Cited by 168
Self-citationHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Metadata
- Authors
- Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2016-06-17
- Volume
- 21
- Issue
- 9
- Pages
- 091310
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2430490683
- Cited by
- 245
- References
- 116
- FWCI
- 21.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.