Enabling CD SEM metrology for 5nm technology node and beyond
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The CD SEM (Critical Dimension Scanning Electron Microscope) is one of the main tools used to estimate Critical Dimension (CD) in semiconductor manufacturing nowadays, but, as all metrology tools, it will face considerable challenges to keep up with the requirements of the future technology nodes. The root causes of these challenges are not uniquely related to the shrinking CD values, as one might expect, but to the increase in complexity of the devices in terms of morphology and chemical composition as well. In fact, complicated threedimensional device architectures, high aspect ratio features, and wide variety of materials are some of the unavoidable characteristics of the future metrology nodes. This means that, beside an improvement in resolution, it is critical to develop a CD SEM metrology capable of satisfying the specific needs of the devices of the nodes to come, needs that sometimes will have to be addressed through dramatic changes in approach with respect to traditional CD SEM metrology. In this paper, we report on the development of advanced CD SEM metrology at imec on a variety of device platform and processes, for both logic and memories. We discuss newly developed approaches for standard, IIIV, and germanium FinFETs (Fin Field Effect Transistors), for lateral and vertical nanowires (NW), 3D NAND (three-dimensional NAND), STT-MRAM (Spin Transfer Magnetic Torque Random-Access Memory), and ReRAM (Resistive Random Access Memory). Applications for both front-end of line (FEOL) and back-end of line (BEOL) are developed. In terms of process, S/D Epi (Source Drain Epitaxy), SAQP (Self-Aligned Quadruple Patterning), DSA (Dynamic Self-Assembly), and EUVL (Extreme Ultraviolet Lithography) have been used. The work reported here has been performed on Hitachi CG5000, CG6300, and CV5000. In terms of logic, we discuss here the S/D epi defect classification, the metrology optimization for STI (Shallow Trench Isolation) Ge FinFETs, the defectivity of III-V STI FinFETs,, metrology for vertical and horizontal NWs. With respect to memory, we discuss a STT-RAM statistical CD analysis and its comparison to electrical performance, ReRAM metrology for VMCO (Vacancy-modulated conductive oxide) with comparison with electrical performance, 3D NAND ONO (Oxide Nitride Oxide) thickness measurements. In addition, we report on 3D morphological reconstruction using CD SEM in conjunction with FIB (Focused Ion Beam), on optimized BKM (Best Known Methods) development methodologies, and on CD SEM overlay. The large variety of results reported here gives a clear overview of the creative effort put in place to ensure that the critical potential of CD SEM metrology tools is fully enabled for the 5nm node and beyond.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A specific type of SEM, critical dimension scanning electron microscopy (CD-SEM), is currently the standard tool in the semiconductor industry for precise measurement of LER and LWR [83].”
From Recent Advances in Metal-Oxide-Based Photoresists for EUV Lithography (2024) · cites this paper as [83]
Citations
Cites
Lorusso, G. F., Inoue, O., Ohashi, T., Sánchez, E. A., Constantoudis, V., & Koshihara, S. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2218863 · Cited by 16
Self-citationSEM based overlay measurement between resist and buried patterns
Inoue, O., Okagawa, Y., Hasumi, K., Shao, C., Leray, P. J., Lorusso, G. F., & Baudemprez, B. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2221910 · Cited by 13
Self-citationMethodology for establishing CD-SEM robust metrology algorithm for development cycles applications
Hitomi, K., Lavigne, E., Hotta, S., Momonoi, Y., Colburn, M. E., Yamaguchi, A., Sasada, K., & Maeda, T. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.916492 · Cited by 5
Self-citationHybrid overlay metrology for high order correction by using CDSEM
Leray, P. J., Halder, S., Lorusso, G. F., Baudemprez, B., Inoue, O., & Okagawa, Y. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2222777 · Cited by 4
Self-citation
Cited by
Directed self-assembly of block copolymers for 7 nanometre FinFET technology and beyond
Liu, C., Franke, E., Mignot, Y., Xie, R., Yeung, C. W., Zhang, J., Chi, C., Zhang, C., Farrell, R. A., Lai, K., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0147-4 · Cited by 138
Stochastic printing failures in extreme ultraviolet lithography
De Bisschop, P. (2018) · Journal of Micro/Nanopatterning, Materials, and Metrology · doi:10.1117/1.jmm.17.4.041011 · Cited by 75
Stochastic effects in EUV lithography
De Bisschop, P., & Hendrickx, E. (2018) · Extreme Ultraviolet (EUV) Lithography IX · doi:10.1117/12.2300541 · Cited by 38
Nohl, J. F., Farr, N. T. H., Sun, Y., Hughes, G. M., Cussen, S. A., & Rodenburg, C. (2022) · Micron · doi:10.1016/j.micron.2022.103234 · Cited by 32
Recent Advances in Metal-Oxide-Based Photoresists for EUV Lithography
Hasan, M. W., Deeb, L., Kumaniaev, S., Wei, C., & Wang, K. (2024) · Micromachines · doi:10.3390/mi15091122 · Cited by 35
“A specific type of SEM, critical dimension scanning electron microscopy (CD-SEM), is currently the standard tool in the semiconductor industry for precise measurement of LER and LWR [83].”
Method
Metadata
- Authors
- Lorusso, G. F., Ohashi, T., Yamaguchi, A., Inoue, O., Sutani, T., Horiguchi, N., Bömmels, J., Wilson, C. J., Briggs, B., Tan, C. L., Raymaekers, T., Delhougne, R., Van den Bosch, G., Di Piazza, L., Kar, G. S., Furnémont, A., Fantini, A., Donadio, G. L., Souriau, L., Crotti, D., Yasin, F., Appeltans, R., Rao, S., De Simone, D., Rincon Delgadillo, P., Leray, P., Charley, A.-L., Zhou, D., Veloso, A., Collaert, N., Hasumi, K., Koshihara, S., Ikota, M., Okagawa, Y., & Ishimoto, T.
- Affiliations
- IMEC (BE)
- Hitachi (Japan) (JP)
- Hitachi High-Tech (Japan) (JP)
- IMEC (Belgium)
- IMEC (Japan)
- ORCID
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2017-03-28
- Volume
- 10145
- Pages
- 1014512
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2597834816
- Cited by
- 11
- References
- 4
- Citations by year
- 2025: 1 · 2024: 2 · 2022: 1 · 2021: 2 · 2018: 5
- FWCI
- 1.93
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Circuits and Semiconductor Failure Analysis
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Electron and X-Ray Spectroscopy Techniques
- Keywords
- CD-SEM, critical dimension measurement, germanium FinFET, nanowires, 3D NAND flash memory, STT-MRAM, resistive random access memory, shallow trench isolation, self-aligned quadruple patterning, dynamic self-assembly, EUV lithography, defect classification, focused ion beam, front-end-of-line, back-end-of-line
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enabling CD SEM metrology for 5nm technology node and beyond. https://app.cochat.ai/papers/10.1117/12.2257468
- The paper
- Lorusso, G. F., Ohashi, T., Yamaguchi, A., Inoue, O., Sutani, T., Horiguchi, N., Bömmels, J., Wilson, C. J., Briggs, B., Tan, C. L., Raymaekers, T., Delhougne, R., Van den Bosch, G., Di Piazza, L., Kar, G. S., Furnémont, A., Fantini, A., Donadio, G. L., Souriau, L., . . . Ishimoto, T. (2017). Enabling CD SEM metrology for 5nm technology node and beyond. SPIE Proceedings. https://doi.org/10.1117/12.2257468
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.