Accuracy of finite element model‐based multi‐organ deformable image registration
Abstract
As more pretreatment imaging becomes integrated into the treatment planning process and full three‐dimensional image‐guidance becomes part of the treatment delivery the need for a deformable image registration technique becomes more apparent. A novel finite element model‐based multi‐organ deformable image registration method, MORFEUS, has been developed. The basis of this method is twofold: first, individual organ deformation can be accurately modeled by deforming the surface of the organ at one instance into the surface of the organ at another instance and assigning the material properties that allow the internal structures to be accurately deformed into the secondary position and second, multi‐organ deformable alignment can be achieved by explicitly defining the deformation of a subset of organs and assigning surface interfaces between organs. The feasibility and accuracy of the method was tested on MR thoracic and abdominal images of healthy volunteers at inhale and exhale. For the thoracic cases, the lungs and external surface were explicitly deformed and the breasts were implicitly deformed based on its relation to the lung and external surface. For the abdominal cases, the liver, spleen, and external surface were explicitly deformed and the stomach and kidneys were implicitly deformed. The average accuracy (average absolute error) of the lung and liver deformation, determined by tracking visible bifurcations, was 0.19 (s.d.: 0.09), 0.28 (s.d.: 0.12) and , in the LR, AP, and IS directions, respectively. The average accuracy of implicitly deformed organs was 0.11 (s.d.: 0.11), 0.13 (s.d.: 0.12), and , in the LR, AP, and IS directions, respectively. The average vector magnitude of the accuracy was for the lung and liver deformation and for the implicitly deformed organs. The two main processes, explicit deformation of the selected organs and finite element analysis calculations, require less than 120 and , respectively. This platform can facilitate the integration of deformable image registration into online image guidance procedures, dose calculations, and tissue response monitoring as well as performing multi‐modality image registration for purposes of treatment planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Self-citationTowards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality
Ling, C. C., Humm, J., Larson, S., Amols, H., Fuks, Z., Leibel, S., & Koutcher, J. A. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00467-3 · Cited by 926
Image registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Acquiring 4D thoracic CT scans using a multislice helical method
Keall, P. J., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V, Stevens, C. W., Vedam, S. S., George, R., Guerrero, T., & Mohan, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/10/015 · Cited by 399
Maes, F., Vandermeulen, D., & Suetens, P. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80030-9 · Cited by 397
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Mah, K., Caldwell, C. B., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., Ehrlich, L. E., & Tirona, R. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01824-7 · Cited by 307
Vanuytsel, L., Vansteenkiste, J., Stroobants, S. G., Leyn, P. R. D., Wever, W. D., Verbeken, E. K., Gatti, G. G., Huyskens, D. P., & Kutcher, G. J. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(00)00138-9 · Cited by 286
A viscous fluid model for multimodal non-rigid image registration using mutual information
D'Agostino, E., Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00039-2 · Cited by 277
Bharatha, A., Hirose, M., Hata, N., Warfield, S. K., Ferrant, M., Zou, K. H., Suarez‐Santana, E., Ruiz‐Alzola, J., D'Amico, A., Cormack, R. A., et al. (2001) · Medical Physics · doi:10.1118/1.1414009 · Cited by 233
Biomechanical 3-D finite element modeling of the human breast using MRI data
Samani, A., Bishop, J., Yaffe, M. J., & Plewes, D. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921476 · Cited by 217
Estimation of 3-D left ventricular deformation from medical images using biomechanical models
Papademetris, X., Sinusas, A. J., Dione, D. P., Constable, R. T., & Duncan, J. S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801163 · Cited by 212
Munley, M. T., Marks, L. B., Scarfone, C., Sibley, G. S., Patz, E. F., Turkington, T. G., Jaszczak, R. J., Gilland, D. R., Anscher, M. S., & Coleman, R. E. (1999) · Lung Cancer · doi:10.1016/s0169-5002(99)00005-7 · Cited by 171
Inclusion of organ deformation in dose calculations
Brock, K. K., McShan, D. L., Haken, R. K. T., Hollister, S. J., Dawson, L. A., & Balter, J. M. (2003) · Medical Physics · doi:10.1118/1.1539039 · Cited by 146
Self-citationMultiscale deformable model segmentation and statistical shape analysis using medial descriptions
Joshi, S. C., Pizer, S. M., Fletcher, P. T., Yushkevich, P. A., Thall, A., & Marron, J. S. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009389 · Cited by 139
Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation
Birkner, M., Yan, D., Alber, M. L., Liang, J., & Nüsslin, F. (2003) · Medical Physics · doi:10.1118/1.1610751 · Cited by 135
Betke, M., Hong, H., Thomas, D., Prince, C. N., & Ko, J. P. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00007-0 · Cited by 123
Re-optimization in adaptive radiotherapy
Wu, C., Jeraj, R., Olivera, G., & Mackie, T. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/17/309 · Cited by 122
In vivo elasticity measurements of extremity skeletal muscle with MR elastography
Uffmann, K., Maderwald, S., Ajaj, W., Galban, C. G., Mateiescu, S., Quick, H. H., & Ladd, M. E. (2004) · NMR in Biomedicine · doi:10.1002/nbm.887 · Cited by 117
Ford, E. C., Chang, J., Mueller, K. D., Sidhu, K., Todor, D. A., Mageras, G. S., Yorke, E. D., Ling, C., & Amols, H. I. (2002) · Medical Physics · doi:10.1118/1.1517614 · Cited by 92
Cai, J., Chu, J. C. H., Recine, D. C., Sharma, M., Nguyen, C., Rodebaugh, R., Saxena, V. A., & Ali, A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00399-x · Cited by 76
Automated generation of a four‐dimensional model of the liver using warping and mutual information
Brock, K., Balter, J. M., Dawson, L. A., Kessler, M. L., & Meyer, C. R. (2003) · Medical Physics · doi:10.1118/1.1576781 · Cited by 74
Self-citationTechnical note: Creating a four‐dimensional model of the liver using finite element analysis
Brock, K. K., Hollister, S. J., Dawson, L. A., & Balter, J. M. (2002) · Medical Physics · doi:10.1118/1.1485055 · Cited by 68
Self-citationOpen low-field magnetic resonance imaging in radiation therapy treatment planning
Krempien, R. C., Schubert, K., Zierhut, D., et al. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02886-9 · Cited by 60
Reducing uncertainties in volumetric image based deformable organ registration
Liang, J., & Yan, D. (2003) · Medical Physics · doi:10.1118/1.1587631 · Cited by 58
Nestle, U., Hellwig, D., Schmidt, S., Licht, N., Walter, K., Ukena, D., Rübe, C., Baumann, M., & Kirsch, C. M. (2002) · Molecular Imaging and Biology · doi:10.1016/s1536-1632(02)00005-7 · Cited by 43
Cited by
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Self-citationMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Image-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496
Self-citation
Metadata
- Authors
- Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2005-05-20
- Volume
- 32
- Issue
- 6Part1
- Pages
- 1647-1659
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2098533585
- Cited by
- 375
- References
- 34
- FWCI
- 25.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.