Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations

Open access
Jones, Bernard L., Krishnan, Sunil, Cho, Sang Hyun·2010·Medical Physics

Abstract

Purpose: An approach known as gold nanoparticle‐aided radiation therapy (GNRT) is a recent development in radiation therapy which seeks to make a tumor more susceptible to radiation damage by modifying its photon interaction properties with an infusion of gold nanoparticles (GNPs). The purpose of this study was to quantify the energy deposition due to secondary electrons from GNPs on a nanometer scale and to calculate the corresponding microscopic dose enhancement factor around GNPs. Methods: The Monte Carlo code EGSnrc was modified to obtain the spectra of secondary electrons from atoms of gold approximating GNPs and molecules of water under photon irradiation of a tumor loaded with GNPs. Six different photon sources were used: , , , , 50 kVp, and 6 MV x rays. Treating the scored electron spectra as point sources within an infinite medium of water, the event‐by‐event Monte Carlo code NOREC was used to quantify the radial dose distribution, giving rise to gold/water electron dose point kernels and corresponding microscopic dose enhancement factors. These kernels were applied to a test case based on a scanning electron microscope image of a GNP distribution in tissue, enabling the determination of the microscopic dose enhancement at each dose point. Results: For the lower energy sources , , , and 50 kVp, the secondary electron fluence within a GNP‐loaded tumor was increased by as much as two orders of magnitude, leading to two orders of magnitude increase in electron energy deposition over radial distances up to . For the test case considered, the dose was enhanced by factors ranging from 2 to 20 within of GNPs, and by 5% as far away as . Conclusions: This study demonstrates a remarkable microscopic dose enhancement due to GNPs and low energy photon sources. By quantifying the microscopic dose enhancement factor for a given photon source as a function of distance from GNPs, it also enables the selection of either a passive or an active tumor targeting strategy using GNPs which will maximize the radiobiological benefit from GNRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.3455703

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 241

Metadata

Authors
Jones, B. L., Krishnan, S., & Cho, S. H.
Venue
Medical Physics
Publisher
Wiley
Published
2010-06-29
Volume
37
Issue
7Part1
Pages
3809-3816
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2015727160
Cited by
241
References
2
FWCI
11.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations. https://app.cochat.ai/papers/10.1118/1.3455703
The paper
Jones, B. L., Krishnan, S., & Cho, S. H. (2010). Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations. Medical Physics. https://doi.org/10.1118/1.3455703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.