Standardized evaluation methodology for 3D/2D registration based on the Visible Human data set
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: A new image database with a reference‐based standardized evaluation methodology for objective evaluation and comparison of three‐dimensional/two‐dimensional (3D/2D) registration methods has been introduced. Methods: Computed tomography (CT) images of a male and female from the Visible Human Project were used and 16 subvolumes, each containing one of vertebrae T3‐T12 and L1‐L5 and the pelvis, were defined from the CTs. Six pairs of 2D fluoroscopic x‐ray images from different views, showing the thoracic, lumbar, and pelvic regions, were rendered from the CT data using a ray‐casting algorithm with an energy conversion function. Furthermore, a single 13‐gauge needle was analytically simulated and projected onto the 2D images. By the novel standardized evaluation methodology, a 3D/2D registration method is evaluated by four evaluation criteria: Accuracy, reliability, robustness, and algorithm complexity. Results: To demonstrate the usefulness of the proposed data set and the standardized evaluation methodology, a part of the data set was used in an evaluation study of two gradient‐based 3D/2D registration methods. It was shown that the use of a failure criterion to calculate the registration accuracy and reliability is not required, since all the information about a registration method can be determined from the estimated distribution of registration errors. Conclusions: The proposed simulated image data set with quite realistic synthetic 2D images, depicting soft tissues and outliers, is especially suitable for preliminary testing of 3D/2D registration algorithms. Since the aim of this article is to provide objective comparison and unbiased evaluation of 3D/2D registration methods, the standardized evaluation methodology is available upon request from the authors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Visible Human Male: A Technical Report
Spitzer, V., Ackerman, M. J., Scherzinger, A. L., & Whitlock, D. (1996) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1996.96236280 · Cited by 705
“Gold standard” data for evaluation and comparison of 3D/2D registration methods
Tomaževič, D., Likar, B., & Pernuš, F. (2004) · Computer Aided Surgery · doi:10.3109/10929080500097687 · Cited by 40
Self-citation
Cited by
3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
Mitrovic, U., Spiclin, Z., Likar, B., & Pernus, F. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2259844 · Cited by 67
Self-citationGendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Self-citationPose Estimation of Periacetabular Osteotomy Fragments With Intraoperative X-Ray Navigation
Grupp, R. B., Hegeman, R. A., Murphy, R. J., Alexander, C. P., Otake, Y., McArthur, B. A., Armand, M., & Taylor, R. H. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2915165 · Cited by 38
Grupp, R. B., Armand, M., & Taylor, R. H. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01201-4_17 · Cited by 23
Metadata
- Authors
- Markelj, P., Likar, B., & Pernuš, F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2010-08-11
- Volume
- 37
- Issue
- 9
- Pages
- 4643-4647
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2085036530
- Cited by
- 18
- References
- 2
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardized evaluation methodology for 3D/2D registration based on the Visible Human data set. https://app.cochat.ai/papers/10.1118/1.3476414
- The paper
- Markelj, P., Likar, B., & Pernuš, F. (2010). Standardized evaluation methodology for 3D/2D registration based on the Visible Human data set. Medical Physics. https://doi.org/10.1118/1.3476414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.