The DOI matches its Crossref record.
Fast calculation of the exact radiological path for a three‐dimensional CT array
Abstract
Ready availability has prompted the use of computed tomography (CT) data in various applications in radiation therapy. For example, some radiation treatment planning systems now utilize CT data in heterogeneous dose calculation algorithms. In radiotherapy imaging applications, CT data are projected onto specified planes, thus producing “radiographs,” which are compared with simulator radiographs to assist in proper patient positioning and delineation of target volumes. All these applications share the common geometric problem of evaluating the radiological path through the CT array. Due to the complexity of the three‐dimensional geometry and the enormous amount of CT data, the exact evaluation of the radiological path has proven to be a time consuming and difficult problem. This paper identifies the inefficient aspect of the traditional exact evaluation of the radiological path as that of treating the CT data as individual voxels. Rather than individual voxels, a new exact algorithm is presented that considers the CT data as consisting of the intersection volumes of three orthogonal sets of equally spaced, parallel planes. For a three‐dimensional CT array of N3 voxels, the new exact algorithm scales with 3 N, the number of planes, rather than N3, the number of voxels. Coded in fortran‐77 on a VAX 11/780 with a floating point option, the algorithm requires approximately 5 ms to calculate an average radiological path in a 100 3 voxel array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
STIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
A Sparse-View CT Reconstruction Method Based on Combination of DenseNet and Deconvolution
Zhang, Z., Liang, X., Dong, X., Xie, Y., & Cao, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823338 · Cited by 447
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 396
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Sidky, E. Y., Jørgensen, J. H., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/10/3065 · Cited by 360
Development of the open-source dose calculation and optimization toolkit matRad
Wieser, H.-P., Cisternas, E., Wahl, N., Ulrich, S., Stadler, A., Mescher, H., Müller, L.-R., Klinge, T., Gabrys, H., Burigo, L., et al. (2017) · Medical Physics · doi:10.1002/mp.12251 · Cited by 325
Practical considerations for 3-D image reconstruction using spherically symmetric volume elements
Matej, S., & Lewitt, R. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481442 · Cited by 314
Lamare, F., Carbayo, M. J. L., Cresson, T., Kontaxakis, G., Santos, A., Rest, C. C. L., Reader, A. J., & Visvikis, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/006 · Cited by 259
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Otake, Y., Schafer, S., Stayman, J. W., Zbijewski, W., Kleinszig, G., Graumann, R., Khanna, A. J., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5485 · Cited by 79
GPU Accelerated Generation of Digitally Reconstructed Radiographs for 2-D/3-D Image Registration
Dorgham, O. M., Laycock, S. D., & Fisher, M. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2207898 · Cited by 56
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Gopalakrishnan, V., & Golland, P. (2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-23179-7_1 · Cited by 50
Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering
Gopalakrishnan, V., Dey, N., & Golland, P. (2024) · 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52733.2024.01108 · Cited by 87
“The discrete line integral is computed as in [47]: where ↵ m parameterizes the locations where r intersects one of the orthogonal planes comprising the CT volume and M is the number of such intersections.”
Method3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
Otake, Y., Wang, A. S., Uneri, A., Kleinszig, G., Vogt, S., Aygun, N., Lo, S.-F. L., Wolinsky, J.-P., Gokaslan, Z. L., & Siewerdsen, J. H. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/5/2075 · Cited by 41
“Simulated PA and LAT radiographs with each random geometry were generated using Siddon’s ray-tracing algorithm (Siddon 1985).”
MethodParallel CT image reconstruction based on GPUs
Flores, L. A., Vidal, V., Mayo, P., Rodenas, F., & Verdú, G. (2014) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2013.03.011 · Cited by 28
Fin, L., Bailly, P., Daouk, J., & Meyer, M. (2009) · Medical Physics · doi:10.1118/1.3152116 · Cited by 18
CT Image Reconstruction Based on GPUs
Flores, L. A., Vidal, V., Mayo, P., Rodenas, F., & Verdú, G. (2013) · Procedia Computer Science · doi:10.1016/j.procs.2013.05.308 · Cited by 16
Rapid patient-specific neural networks for intraoperative X-ray to volume registration
Gopalakrishnan, V., Chlorogiannis, D.-D., Abumoussa, A., Larson, A. M., Haouchine, N., Orbach, D. B., Frisken, S., Dey, N., & Golland, P. (2025) · arXiv · doi:10.48550/arxiv.2503.16309 · Cited by 13
Abumoussa, A., Gopalakrishnan, V., Succop, B., Galgano, M., Jaikumar, S., Lee, Y. Z., & Bhowmick, D. A. (2023) · Neurosurgical Focus · doi:10.3171/2023.3.focus2345 · Cited by 9
Metadata
- Authors
- Siddon, R. L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1985-03
- Volume
- 12
- Issue
- 2
- Pages
- 252-255
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2055483062
- Cited by
- 1,535
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.