The DOI matches its Crossref record.
Computerized three‐dimensional segmented human anatomy
Abstract
Manual segmentation of 129 x‐ray CT transverse slices of a living male human has been done and a computerized 3‐dimensional volume array modeling all major internal structures of the body has been created. Each voxel of the volume contains a index number designating it as belonging to a given organ or internal structure. The original x‐ray CT images were reconstructed in a 512×512 matrix with a resolution of 1 mm in the x,y plane. The z‐axis resolution is 1 cm from neck to midthigh and 0.5 cm from neck to crown of the head. This volume array represents a high resolution model of the human anatomy and can serve as a voxel‐based anthropomorphic phantom suitable for many computer‐based modeling and simulation calculations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Sarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., et al. (2014) · Medical Physics · doi:10.1118/1.4871617 · Cited by 573
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
A study of the handset antenna and human body interaction
Okoniewski, M., & Stuchly, M. A. (1996) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.539944 · Cited by 390
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Liu, T., Wisnieff, C., Lou, M., Chen, W., Spincemaille, P., & Wang, Y. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24272 · Cited by 360
PHYSICAL MODELS AND DOSE FACTORS FOR USE IN INTERNAL DOSE ASSESSMENT
Stabin, M. G., & Siegel, J. A. (2003) · Health Physics · doi:10.1097/00004032-200309000-00006 · Cited by 313
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
The GSF family of voxel phantoms
Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/307 · Cited by 280
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279
Specific absorption rate and temperature increases in the head of a cellular-phone user
Bernardi, P., Cavagnaro, M., Pisa, S., & Piuzzi, E. (2000) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.848494 · Cited by 278
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276
Surface-based labeling of cortical anatomy using a deformable atlas
Sandor, S., & Leahy, R. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.552054 · Cited by 274
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Development of targeted alpha particle therapy for solid tumors.
Tafreshi, N. K., Doligalski, M. L., Tichacek, C. J., Pandya, D. N., Budzevich, M. M., El-Haddad, G., Khushalani, N. I., Moros, E. G., McLaughlin, M. L., Wadas, T. J., et al. (2019) · Molecules · doi:10.3390/molecules24234314 · Cited by 157
“Later, as computational power increased, voxelized phantoms like VoxelMan were created based off 3D imaging [124].”
BackgroundWireless power transfer to a cardiac implant
Kim, S., Ho, J. S., Chen, L. Y., & Poon, A. S. Y. (2012) · Applied Physics Letters · doi:10.1063/1.4745600 · Cited by 148
Reitz, G., Berger, T., Bilski, P., Facius, R., Hajek, M., Petrov, V., Puchalska, M., Zhou, D., Bossler, J., Akatov, Y., et al. (2009) · Radiation Research · doi:10.1667/rr1559.1 · Cited by 128
Schneider, U., & Walsh, L. (2008) · Radiation and Environmental Biophysics · doi:10.1007/s00411-007-0151-y · Cited by 94
A Wireless Magnetoresistive Sensing System for an Intraoral Tongue-Computer Interface
Park, H., Kiani, M., Lee, H.-M., Kim, J., Block, J., Gosselin, B., & Ghovanloo, M. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2227962 · Cited by 79
Metadata
- Authors
- Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1994-02
- Volume
- 21
- Issue
- 2
- Pages
- 299-302
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2112155856
- Cited by
- 1,103
- References
- 0
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.