The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Algorithm for image reconstruction in multi-slice helical CT
Abstract
Efforts are being made to develop a new type of CT system that can scan volumes over a large range within a short time with thin slice images. One of the most promising approaches is the combination of helical scanning with multi-slice CT, which involves several detector arrays stacked in the z direction. However, the algorithm for image reconstruction remains one of the biggest problems in multi-slice CT. Two helical interpolation methods for single-slice CT, 360LI and 180LI, were used a starting points and extended to multi-slice CT. The extended methods, however, had a serious image quality problem due to the following three reasons: (1) excessively close slice positions of the complementary and direct data, resulting in a larger sampling interval; (2) the existence of several discontinuous changeovers in pairs of data samples for interpolation; and (3) the existence of cone angles. Therefore we have proposed a new algorithm to overcome the problem. It consists of the following three parts: (1) optimized sampling scan; (2) filter interpolation; and (3) fan-beam reconstruction. Optimized sampling scan refers to a special type of multi-slice helical scan developed to shift the slice position of complementary data and to acquire data with a much smaller sampling interval in the z direction. Filter interpolation refers to a filtering process performed in the z direction using several data. The normal fan-beam reconstruction technique is used. The section sensitivity profile (SSP) and image quality for four-array multi-slice CT were investigated by computer simulations. Combinations of three types of optimized sampling scan and various filter widths were used. The algorithm enables us to achieve acceptable image quality and spatial resolution at a scanning speed that is about three times faster than that for single-slice CT. The noise characteristics show that the proposed algorithm efficiently utilizes the data collected with optimized sampling scan. The new algorithm allows suitable combinations of scan and filter parameters to be selected to meet the purpose of each examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
A general cone-beam reconstruction algorithm
Wang, G., Lin, T.-H., Cheng, P., & Shinozaki, D. M. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241876 · Cited by 333
Cited by
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Metadata
- Authors
- Taguchi, K., & Aradate, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1998-04
- Volume
- 25
- Issue
- 4
- Pages
- 550-561
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2028236273
- Cited by
- 286
- References
- 2
- FWCI
- 18.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.