The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Open accessAbstract
Monte Carlo techniques have become popular in different areas of medical physics with advantage of powerful computing systems. In particular, they have been extensively applied to simulate processes involving random behavior and to quantify physical parameters that are difficult or even impossible to calculate by experimental measurements. Recent nuclear medical imaging innovations such as single-photon emission computed tomography (SPECT), positron emission tomography (PET), and multiple emission tomography (MET) are ideal for Monte Carlo modeling techniques because of the stochastic nature of radiation emission, transport and detection processes. Factors which have contributed to the wider use include improved models of radiation transport processes, the practicality of application with the development of acceleration schemes and the improved speed of computers. In this paper we present a derivation and methodological basis for this approach and critically review their areas of application in nuclear imaging. An overview of existing simulation programs is provided and illustrated with examples of some useful features of such sophisticated tools in connection with common computing facilities and more powerful multiple-processor parallel processing systems. Current and future trends in the field are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Validity of the single processor approach to achieving large scale computing capabilities
Amdahl, G. M. (1967) · Proceedings of the April 18-20, 1967, spring joint computer conference on - AFIPS '67 (Spring) · doi:10.1145/1465482.1465560 · Cited by 4,339
Snir, M., Otto, S. W., WALKER, D. W., Dongarra, J. J., & Huss‐Lederman, S. (1996) · Cited by 2,152
Crimins, F. (2003) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-003-0001-6 · Cited by 2,000
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Performance of various computers using standard linear equations software
Dongarra, J. J. (1992) · ACM SIGARCH Computer Architecture News · doi:10.1145/141868.141871 · Cited by 708
Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Monte Carlo theory and practice
James, F. (1980) · Reports on Progress in Physics · doi:10.1088/0034-4885/43/9/002 · Cited by 544
A Monte Carlo program for the simulation of scintillation camera characteristics
Ljungberg, M., & Strand, S.-E. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90111-9 · Cited by 515
MIRDOSE: Personal Computer Software for Internal Dose Assessment in Nuclear Medicine
Piwnica-Worms, D. (1996) · Cited by 500
Mathematical Methods in Large-scale Computing Units
Lehmer, D. H. (1951) · Cited by 455
Monte Carlo simulations: Hidden errors from ‘‘good’’ random number generators
Ferrenberg, A. M., Landau, D. P., & Wong, Y. J. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.3382 · Cited by 437
Monte Carlo Transport of Electrons and Photons
(1988) · Springer eBooks · doi:10.1007/978-1-4613-1059-4 · Cited by 436
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Treatment of axial data in three-dimensional PET.
Daube-Witherspoon, M. E., & Muehllehner, G. (1987) · PubMed · Cited by 357
3-D phantom to simulate cerebral blood flow and metabolic images for PET
Hoffman, E. J., Cutler, P. D., Digby, W. M., & Mazziotta, J. C. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106686 · Cited by 353
SCINTILLATION CAMERA WITH MULTICHANNEL COLLIMATORS.
Anger, H. O. (1964) · PubMed · Cited by 335
Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.
Weber, D. A., Ivanović, M., Franceschi, D., et al. (1994) · PubMed · Cited by 223
Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
Watson, C. C., Newport, D., Casey, M. E., deKemp, R. A., Beanlands, R. S., & Schmand, M. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.554831 · Cited by 218
Rosenthal, M. S., Cullom, J., Hawkins, W. G., Moore, S. C., Tsui, B. M. W., & Yester, M. V. (1995) · PubMed · Cited by 210
Use of Different Monte Carlo Sampling Techniques
Kahn, H. (1955) · Cited by 204
Inverse Monte Carlo: A Unified Reconstruction Algorithm for SPECT
Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1985) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1985.4336940 · Cited by 196
Design studies for a PET detector module using a PIN photodiode to measure depth of interaction
Moses, W. W., & Derenzo, S. E. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.322929 · Cited by 183
Zankl, M., Veit, R., Williams, G., Schneider, K., Fendel, H., Petoussi, N., & Drexler, G. (1988) · Radiation and Environmental Biophysics · doi:10.1007/bf01214605 · Cited by 172
Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry
ROGERS, D. W. O., & BIELAJEW, A. F. (1990) · The Dosimetry of Ionizing Radiation · doi:10.1016/b978-0-12-400403-0.50009-9 · Cited by 170
Buvat, I., Rodríguez‐Villafuerte, M., Todd-Pokropek, A. E., Benali, H., & Paola, R. D. (1995) · PubMed · Cited by 125
Fully Bayesian estimation of Gibbs hyperparameters for emission computed tomography data
Higdon, D., Bowsher, J. E., Johnson, V. E., Turkington, T. G., Gilland, D. R., & Jaszczak, R. J. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640741 · Cited by 115
A mouse model for calculating cross-organ beta doses from yttrium-90-labeled immunoconjugates
Hui, T. E., Fisher, D. R., Kuhn, J. A., Williams, L. E., Nourigat, C., Badger, C. C., Beatty, B., & Beatty, J. D. (1994) · Cancer · Cited by 114
A microdosimetric model of astatine-211 labeled antibodies for radioimmunotherapy
Humm, J. L. (1987) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(87)90176-3 · Cited by 110
Random Number Generators on Vector Supercomputers and Other Advanced Architectures
Anderson, S. L. (1990) · SIAM Review · doi:10.1137/1032044 · Cited by 109
Comparison of four scatter correction methods using Monte Carlo simulated source distributions.
Ljungberg, M. H., King, M. A., Hádemenos, G. J., & Strand, S. (1994) · PubMed · Cited by 108
Narita, Y., Eberl, S., Iida, H., et al. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/017 · Cited by 102
Monkey tests for random number generators
Marsaglia, G., & Zaman, A. (1993) · Computers & Mathematics with Applications · doi:10.1016/0898-1221(93)90001-c · Cited by 102
Bowsher, J. E., & Floyd, C. E. (1991) · PubMed · Cited by 86
Monte Carlo methods for radiation transport analysis on vector computers
Brown, F. B., & Martin, W. R. (1984) · Progress in Nuclear Energy · doi:10.1016/0149-1970(84)90024-6 · Cited by 84
King, M. A., Xia, W., deVries, D. J., Pan, T.-S., Villegas, B. J., Dahlberg, S. T., Tsui, B. M. W., Ljungberg, M. H., & Morgan, H. T. (1996) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(96)90020-3 · Cited by 82
A comparative study of some pseudorandom number generators
Vattulainen, I., Kankaala, K., Saarinen, J. P. P., & Ala-Nissilä, T. (1995) · Computer Physics Communications · doi:10.1016/0010-4655(95)00015-8 · Cited by 71
Monte carlo methods in chemical physics
Ferguson, D. M., Siepmann, J. I., & Truhlar, D. G. (1999) · Cited by 68
On the Periods of Generalized Fibonacci Recurrences
Brent, R. P. (1994) · Mathematics of Computation · doi:10.2307/2153583 · Cited by 63
Fast SPECT simulation including object shape dependent scatter
Beekman, F. J., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387709 · Cited by 55
Pan, T., King, M. A., de Vries, D. J., & Ljungberg, M. H. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481437 · Cited by 52
Design and Analysis of Parallel Monte Carlo Algorithms
Bhavsar, V. C., & Isaac, J. R. (1987) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0908014 · Cited by 47
A Fast, High Quality, and Reproducible Parallel Lagged-Fibonacci Pseudorandom Number Generator
Mascagni, M., Cuccaro, S. A., Pryor, D. V., & Robinson, M. L. (1995) · Journal of Computational Physics · doi:10.1006/jcph.1995.1130 · Cited by 44
Random Number Generators for Parallel Applications
Srinivasan, A., Ceperley, D. M., & Mascagni, M. (1999) · Advances in chemical physics · doi:10.1002/9780470141649.ch2 · Cited by 43
Development of a SPECT-based three-dimensional treatment planning system for radioimmunotherapy.
Giap, H., Macey, D. J., & Podoloff, D. A. (1995) · PubMed · Cited by 40
Zaidi, H., Labbé, C., & Morel, C. (1998) · Parallel Computing · doi:10.1016/s0167-8191(98)00069-6 · Cited by 38
Self-citationStatus of Vectorized Monte Carlo for Particle Transport Analysis
Martin, W. R., & Brown, F. B. (1987) · The International Journal of High Performance Computing Applications · doi:10.1177/109434208700100203 · Cited by 38
Compensation for crystal penetration in high resolution positron tomography
Huesman, R. H., Salmeron, E. M., & Baker, J. R. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34612 · Cited by 37
Yanch, J. C., Dobrzeniecki, A. B., Ramanathan, C., & Behrman, R. H. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/4/003 · Cited by 35
Chinn, G., & Huang, S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.552050 · Cited by 35
Controlling correlations in parallel Monte Carlo
Matteis, A. D., & Pagnutti, S. (1995) · Parallel Computing · doi:10.1016/0167-8191(94)00073-j · Cited by 34
A class of parallel random number generators
Matteis, A. D., & Pagnutti, S. (1990) · Parallel Computing · doi:10.1016/0167-8191(90)90146-z · Cited by 33
Compensation for collimator divergence in SPECT using inverse Monte Carlo reconstruction
Floyd, C. E., Jaszczak, R. J., Manglos, S. H., & Coleman, R. E. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12832 · Cited by 32
Use of a neural network to exploit light division in a triangular scintillating crystal
Delorme, S., Frei, R., Joseph, C., Loude, J.-F., & Morel, C. (1996) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(95)01511-6 · Cited by 28
Conceptual design of a whole body PET machine
Rogers, J. G., Harrop, R., Kinahan, P. E., Wilkinson, N. A., Coombes, G. H., Doherty, P. W., & Saylor, D. P. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12811 · Cited by 27
Convergence of the maximum likelihood reconstruction algorithm for emission computed tomography
Floyd, C. E., Jaszczak, R. J., & Coleman, R. E. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/4/005 · Cited by 24
Tracer kinetic modelling of receptor data with mathematical metabolite correction
Burger, C., & Buck, A. (1996) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00833389 · Cited by 18
Cristy, M. (1983) · Physics in Medicine and Biology · doi:10.1088/0031-9155/28/11/009 · Cited by 17
Kramer, G. H., Chamberlain, M. J., & Yiu, S. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/012 · Cited by 6
Computer model of an inhomogeneous human torso
Sui, W., & Shen, F. (1990) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(90)90132-7 · Cited by 3
Cited by
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
Metadata
- Authors
- Zaidi, H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1999-04
- Volume
- 26
- Issue
- 4
- Pages
- 574-608
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2038253228
- Cited by
- 279
- References
- 62
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.