The DOI matches its Crossref record.
Speech recognition with altered spectral distribution of envelope cues
Abstract
Recognition of consonants, vowels, and sentences was measured in conditions of reduced spectral resolution and distorted spectral distribution of temporal envelope cues. Speech materials were processed through four bandpass filters (analysis bands), half-wave rectified, and low-pass filtered to extract the temporal envelope from each band. The envelope from each speech band modulated a band-limited noise (carrier bands). Analysis and carrier bands were manipulated independently to alter the spectral distribution of envelope cues. Experiment I demonstrated that the location of the cutoff frequencies defining the bands was not a critical parameter for speech recognition, as long as the analysis and carrier bands were matched in frequency extent. Experiment II demonstrated a dramatic decrease in performance when the analysis and carrier bands did not match in frequency extent, which resulted in a warping of the spectral distribution of envelope cues. Experiment III demonstrated a large decrease in performance when the carrier bands were shifted in frequency, mimicking the basal position of electrodes in a cochlear implant. And experiment IV showed a relatively minor effect of the overlap in the noise carrier bands, simulating the overlap in neural populations responding to adjacent electrodes in a cochlear implant. Overall, these results show that, for four bands, the frequency alignment of the analysis bands and carrier bands is critical for good performance, while the exact frequency divisions and overlap in carrier bands are not as critical.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Self-citationDavis, M. H., Johnsrude, I. S., Hervais-Adelman, A., Taylor, K., & McGettigan, C. (2005) · Journal of Experimental Psychology General · doi:10.1037/0096-3445.134.2.222 · Cited by 531
Frequency Map for the Human Cochlear Spiral Ganglion: Implications for Cochlear Implants
Stakhovskaya, O., Sridhar, D., Bonham, B. H., & Leake, P. A. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0076-9 · Cited by 414
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Self-citationFishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Self-citationCombining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Self-citationRosen, S., Faulkner, A., & Wilkinson, L. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.428215 · Cited by 253
Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
Self-citationEisner, F., McGettigan, C., Faulkner, A., Rosen, S., & Scott, S. K. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4040-09.2010 · Cited by 108
“Thereby, the speech signal is in effect shifted up in frequency (Dorman et al., 1997; Shannon et al., 1998; Rosen et al., 1999).”
BackgroundMethod
Metadata
- Authors
- Shannon, R. V., Zeng, F.-G., & Wygonski, J.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 1998-10-01
- Volume
- 104
- Issue
- 4
- Pages
- 2467-2476
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W1976332190
- Cited by
- 193
- References
- 0
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.