Variability of Measurements of Sweat Sodium Using the Regional Absorbent-Patch Method
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Context: There is interest in including recommendations for the replacement of the sodium lost in sweat in individualized hydration plans for athletes. Purpose: Although the regional absorbent-patch method provides a practical approach to measuring sweat sodium losses in field conditions, there is a need to understand the variability of estimates associated with this technique. Methods: Sweat samples were collected from the forearms, chest, scapula, and thigh of 12 cyclists during 2 standardized cycling time trials in the heat and 2 in temperate conditions. Single measure analysis of sodium concentration was conducted immediately by ion-selective electrodes (ISE). A subset of 30 samples was frozen for reanalysis of sodium concentration using ISE, flame photometry (FP), and conductivity (SC). Results: Sweat samples collected in hot conditions produced higher sweat sodium concentrations than those from the temperate environment (P = .0032). A significant difference (P = .0048) in estimates of sweat sodium concentration was evident when calculated from the forearm average (mean ± 95% CL; 64 ± 12 mmol/L) compared with using a 4-site equation (70 ± 12 mmol/L). There was a high correlation between the values produced using different analytical techniques (r2 = .95), but mean values were different between treatments (frozen FP, frozen SC > immediate ISE > frozen ISE; P < .0001). Conclusion: Whole-body sweat sodium concentration estimates differed depending on the number of sites included in the calculation. Environmental testing conditions should be considered in the interpretation of results. The impact of sample freezing and subsequent analytical technique was small but statistically significant. Nevertheless, when undertaken using a standardized protocol, the regional absorbent-patch method appears to be a relatively robust field test.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“sweat [Na+] varies significantly among common analytical techniques”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Dziedzic et al. 2014
In the citing paper
“in general, ion conductivity > flame photometry ≥ indirect ion-selective electrode > direct ion-selective electrode ≥ ion chromatography”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Dziedzic et al. 2014
In the citing paper
“Furthermore, studies have demonstrated significant changes in sweat [Na+], [Cl−], and/or [K+] in response to variations in exercise intensity (Baker et al. 2019), environment (Dziedzic et al. 2014), or diet (McCubbin et al. 2019) despite no significant differences in hydration status during exercise.”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Dziedzic et al. 2014
Citations
Cites
ACSM Position Stand: Exercise and Fluid Replacement
Convertino, V. A., Armstrong, L. E., Coyle, E. F., Mack, G. W., Sawka, M. N., Senay, L. C., & Sherman, W. M. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199610000-00045 · Cited by 1,965
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
Role of osmolality and plasma volume during rehydration in humans
Nose, H., Mack, G. W., Shi, X. R., & Nadel, E. R. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.1.325 · Cited by 304
Shirreffs, S. M., & Maughan, R. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.336 · Cited by 251
Baker, L. B., Stofan, J. R., Hamilton, A. A., & Horswill, C. A. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00197.2009 · Cited by 189
Sodium ion concentration vs. sweat rate relationship in humans
Buono, M. J., Ball, K. D., & Kolkhorst, F. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00015.2007 · Cited by 186
Fluid and electrolyte loss and replacement in exercise
Maughan, R. J. (1991) · Journal of Sports Sciences · doi:10.1080/02640419108729870 · Cited by 184
Influence of acclimatization on sweat sodium concentration.
Allan, J. R., & Wilson, C. G. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.30.5.708 · Cited by 171
Development of Individual Hydration Strategies for Athletes
Maughan, R. J., & Shirreffs, S. M. (2008) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.18.5.457 · Cited by 135
Sweat and Sodium Losses in NCAA Football Players: A Precursor to Heat Cramps?
Stofan, J. R., Zachwieja, J. J., Horswill, C. A., Murray, R., Anderson, S. A., & Eichner, E. R. (2005) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.15.6.641 · Cited by 123
Research works printed but not linked: 2
- Preusse CJ, 1979, J Clin Chem Clin Biochem., 17, 639
- Kulpmann WR, 1985, J Clin Chem Clin Biochem., 23, 865
Cited by
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
“Techniques that are more amenable to sweat analysis in the field include ISE and conductivity.”
BackgroundMethodInfluentialPhysiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
A Textile‐Based Stretchable Multi‐Ion Potentiometric Sensor
Parrilla, M., Cánovas, R., Jeerapan, I., Andrade, F. J., & Wang, J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600092 · Cited by 269
Metadata
- Authors
- Dziedzic, C. E., Ross, M. L., Slater, G. J., & Burke, L. M.
- Venue
- International Journal of Sports Physiology and Performance
- Publisher
- Human Kinetics
- Published
- 2014-09
- Volume
- 9
- Issue
- 5
- Pages
- 832-838
- ISSN
- 1555-0265 (ISSN-L)
- 1555-0273
- OpenAlex
- W2097532939
- Cited by
- 49
- References
- 25
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 8 · 2021: 1 · 2020: 7 · 2019: 4 · 2018: 7 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 3
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Sports Physiology and Performance (publishedVersion)
- PubMed (publishedVersion)
- Research Bank (Australian Catholic University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- sweat sodium, measurement variability, sweat loss, cyclists, heat exposure, sample freezing, flame photometry, ion-selective electrodes, conductivity
- MeSH terms
- Absorption, Adult, Bicycling, Electric Conductivity, Hot Temperature, Humans, Male, Models, Biological, Photometry, Sodium, Specimen Handling, Sweat, Sweating, Time Factors, Water-Electrolyte Balance, Reproducibility of Results, Biomarkers, Exercise, Ion-Selective Electrodes, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability of Measurements of Sweat Sodium Using the Regional Absorbent-Patch Method. https://app.cochat.ai/papers/10.1123/ijspp.2013-0480
- The paper
- Dziedzic, C. E., Ross, M. L., Slater, G. J., & Burke, L. M. (2014). Variability of Measurements of Sweat Sodium Using the Regional Absorbent-Patch Method. International Journal of Sports Physiology and Performance. https://doi.org/10.1123/ijspp.2013-0480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.