CoChat

Variability of Measurements of Sweat Sodium Using the Regional Absorbent-Patch Method

Dziedzic, Christine E., Ross, Megan L., Slater, Gary J., Burke, Louise M. · 2014 · International Journal of Sports Physiology and Performance

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Context: There is interest in including recommendations for the replacement of the sodium lost in sweat in individualized hydration plans for athletes. Purpose: Although the regional absorbent-patch method provides a practical approach to measuring sweat sodium losses in field conditions, there is a need to understand the variability of estimates associated with this technique. Methods: Sweat samples were collected from the forearms, chest, scapula, and thigh of 12 cyclists during 2 standardized cycling time trials in the heat and 2 in temperate conditions. Single measure analysis of sodium concentration was conducted immediately by ion-selective electrodes (ISE). A subset of 30 samples was frozen for reanalysis of sodium concentration using ISE, flame photometry (FP), and conductivity (SC). Results: Sweat samples collected in hot conditions produced higher sweat sodium concentrations than those from the temperate environment (P = .0032). A significant difference (P = .0048) in estimates of sweat sodium concentration was evident when calculated from the forearm average (mean ± 95% CL; 64 ± 12 mmol/L) compared with using a 4-site equation (70 ± 12 mmol/L). There was a high correlation between the values produced using different analytical techniques (r2 = .95), but mean values were different between treatments (frozen FP, frozen SC > immediate ISE > frozen ISE; P < .0001). Conclusion: Whole-body sweat sodium concentration estimates differed depending on the number of sites included in the calculation. Environmental testing conditions should be considered in the interpretation of results. The impact of sample freezing and subsequent analytical technique was small but statistically significant. Nevertheless, when undertaken using a standardized protocol, the regional absorbent-patch method appears to be a relatively robust field test.

Overview

Integrity signals

Registry

Crossref · 10.1123/ijspp.2013-0480

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. Preusse CJ, 1979, J Clin Chem Clin Biochem., 17, 639
  2. Kulpmann WR, 1985, J Clin Chem Clin Biochem., 23, 865

Cited by

See all 50

Metadata

Authors
Dziedzic, C. E., Ross, M. L., Slater, G. J., & Burke, L. M.
Venue
International Journal of Sports Physiology and Performance
Published
2014-09
Volume
9
Issue
5
Pages
832-838
ISSN
  • 1555-0265 (ISSN-L)
  • 1555-0273
OpenAlex
W2097532939
Cited by
49
References
25
Citations by year
2026: 4 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 8 · 2021: 1 · 2020: 7 · 2019: 4 · 2018: 7 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 3
FWCI
2.22
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Sports Physiology and Performance (publishedVersion)
  • PubMed (publishedVersion)
  • Research Bank (Australian Catholic University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
sweat sodium, measurement variability, sweat loss, cyclists, heat exposure, sample freezing, flame photometry, ion-selective electrodes, conductivity
MeSH terms
Absorption, Adult, Bicycling, Electric Conductivity, Hot Temperature, Humans, Male, Models, Biological, Photometry, Sodium, Specimen Handling, Sweat, Sweating, Time Factors, Water-Electrolyte Balance, Reproducibility of Results, Biomarkers, Exercise, Ion-Selective Electrodes, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.