Stabilizing Bioimpedance-Vector-Analysis Measures With a 10-Minute Cold Shower After Running Exercise to Enable Assessment of Body Hydration
Open accessAbstract
Purpose: The exercise-induced increase in skin and body temperature, cutaneous blood flow, and electrolyte accumulation on the skin affects the validity of bioimpedance analysis to assess postexercise changes in hydration. This study aimed to assess the influence of a 10-min cold (22°C) shower on the time course of impedance measurements after controlled exercise. Methods: In total, 10 male athletes (age 26.2 [4.1] y and body mass index 23.9 [1.7] kg/m 2) were tested on 2 different days. During both trials, athletes ran for 30 min on a treadmill in a room at 23°C. In a randomized crossover trial, the participants underwent a 10-min cold shower on the trial occasion and did not shower in the control trial. Bioimpedance analysis variables were measured before running (ie, baseline [T0]), immediately after exercising (T1), and 20 (T2), 40 (T3), and 60 min (T4) after the exercise. The shower was performed after T1 in the shower trial. Results: Body weight decreased similarly in both trials (−0.4% [0.1%], P < .001; −0.4% [0.1%], P < .001). Resistance and vector length returned to baseline at T2 in the shower trial, whereas baseline values were achieved at T3 in the control trial (P > .05). In the control trial, reactance remained at a lower level for the entire testing period (38.1 [6.9] vs 37.3 [6.7], P < .001). Forehead skin temperature returned to baseline values at T2 with shower, whereas it was still high at T4 without shower (P < .001). Conclusions: The present data show that a 10-min cold shower enables the stabilization of bioimpedance analysis measurements within 20 min after exercise, which might facilitate the assessment of hydration change after exercise.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Inconsistencies in methodological procedures for BIA may have impacted the final outcomes for each study.
“inconsistencies in methodological procedures (e.g., the standardization of food and beverage intake before the assessment, electrode placement, skin cleansing) may have impacted the final outcomes for each study [108].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [108]
The Introduction and Discussion (pages unavailable) explain that skin temperature, blood flow, and electrolytes on the skin can affect BIA readings; the study also found that a standardized cold shower changed how quickly readings stabilized. This supports the general concern that assessment conditions may affect outcomes, but the paper does not establish effects of differences in food or beverage intake, electrode placement, or skin cleansing across the studies cited. (LLM, conf=0.82)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580 · see citing works
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350 · see citing works
Phase angle and its determinants in healthy subjects: influence of body composition
González, M. C., Barbosa-Silva, T. G., Bielemann, R. M., Gallagher, D., & Heymsfield, S. B. (2016) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.116772 · Cited by 328 · see citing works
Bivariate normal values of the bioelectrical impedance vector in adult and elderly populations
Piccoli, A., Nigrelli, S., Caberlotto, A., Bottazzo, S., Rossi, B., Pillon, L., & Maggiore, Q. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/61.2.269 · Cited by 261 · see citing works
Bioimpedance and Impedance Vector Patterns as Predictors of League Level in Male Soccer Players
Micheli, M. L., Pagani, L., Marella, M., Gulisano, M., Piccoli, A., Angelini, F., Burtscher, M., & Gatterer, H. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0119 · Cited by 106 · see citing works
Self-citationLukaski, H. C., & Piccoli, A. (2012) · Springer eBooks · doi:10.1007/978-1-4419-1788-1_16 · Cited by 62 · see citing works
Self-citationBioimpedance Vector Analysis of Elite, Subelite, and Low-Level Male Volleyball Players
Campa, F., & Toselli, S. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0039 · Cited by 49 · see citing works
Self-citationBioimpedance Identifies Body Fluid Loss after Exercise in the Heat: A Pilot Study with Body Cooling
Gatterer, H., Schenk, K., Laninschegg, L., Schlemmer, P., Lukaski, H. C., & Burtscher, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0109729 · Cited by 45 · see citing works
Self-citationThe effect of ambient air temperature on whole-body bioelectrical impedance
Buono, M. J., Burke, S. P., Endemann, S., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/011 · Cited by 33 · see citing works
Body fluid status and physical demand during the Giro d’Italia
Pollastri, L., Lanfranconi, F., Tredici, G., et al. (2016) · Research in Sports Medicine · doi:10.1080/15438627.2015.1126273 · Cited by 23 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Campa, F., Toselli, S., Mazzilli, M., Gobbo, L. A., & Coratella, G. (2021) · Nutrients · doi:10.3390/nu13051620 · Cited by 315 · see citing works
Self-citationCampa, F., Coratella, G., Cerullo, G., Noriega, Z., Francisco, R., Charrier, D., Irurtia, A., Lukaski, H., Silva, A. M., & Paoli, A. (2024) · Journal of Translational Medicine · doi:10.1186/s12967-024-05272-x · Cited by 80 · see citing works
“Therefore, inconsistencies in methodological procedures (e.g., the standardization of food and beverage intake before the assessment, electrode placement, skin cleansing) may have impacted the final outcomes for each study [108].”
BackgroundSelf-citationSomatotype and Bioimpedance Vector Analysis: A New Target Zone for Male Athletes
Campa, F., Silva, A. M., Talluri, J., Matias, C. N., Badicu, G., & Toselli, S. (2020) · Sustainability · doi:10.3390/su12114365 · Cited by 39 · see citing works
Self-citationCampa, F., Silva, A. M., Matias, C. N., Monteiro, C. P., Paoli, A., Nunes, J. P., Talluri, J., Lukaski, H., & Toselli, S. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186604 · Cited by 33 · see citing works
Self-citationCampa, F., Bongiovanni, T., Rossi, A., Cerullo, G., Casolo, A., Martera, G., Trecroci, A., Moro, T., & Paoli, A. (2023) · Journal of Translational Medicine · doi:10.1186/s12967-023-04795-z · Cited by 16 · see citing works
“After cleaning the skin with isopropyl alcohol, two adhesive electrodes (Biatrodes Akern Srl, Fire-nze, Italy) were applied on the surface of the right hand and two on the right foot, according to the guidelines for athletes [17, 35].”
MethodSelf-citation
- Authors
- Campa, F., Gatterer, H., Lukaski, H., & Toselli, S.
- Affiliations
- University of Bologna (IT)
- Eurac Research (IT)
- University of North Dakota (US)
- Corresponding author
- Gatterer, Hannes
- Venue
- International Journal of Sports Physiology and Performance
- Publisher
- Human Kinetics
- Published
- 2019-08-01
- Volume
- 14
- Issue
- 7
- Pages
- 1006-1009
- ISSN
- 1555-0265 (ISSN-L)
- 1555-0273
- OpenAlex
- W2911688260
- Cited by
- 33
- References
- 10
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 5 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 10 · 2019: 4
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- International Journal of Sports Physiology and Performance (publishedVersion)
- PubMed (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Open Research (University of Surrey) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Keywords
- bioelectrical impedance analysis, body hydration, cold showers, running, skin temperature, vector length, reactance, athletes
- MeSH terms
- Organism Hydration Status, Adult, Baths, Cold Temperature, Humans, Male, Running, Skin Temperature, Electric Impedance, Cross-Over Studies, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review