CoChat

An Open-Source Monitor-Independent Movement Summary for Accelerometer Data Processing

Open access
John, Dinesh, Tang, Qu, Albinali, Fahd, Intille, Stephen · 2019 · Journal for the Measurement of Physical Behaviour
Cited by 211

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Background: Physical behavior researchers using motion sensors often use acceleration summaries to visualize, clean, and interpret data. Such output is dependent on device specifications (e.g., dynamic range, sampling rate) and/or are proprietary, which invalidate cross-study comparison of findings when using different devices. This limits flexibility in selecting devices to measure physical activity, sedentary behavior, and sleep. Purpose: Develop an open-source, universal acceleration summary metric that accounts for discrepancies in raw data among research and consumer devices. Methods: We used signal processing techniques to generate a Monitor-Independent Movement Summary unit (MIMS-unit) optimized to capture normal human motion. Methodological steps included raw signal harmonization to eliminate inter-device variability (e.g., dynamic g-range, sampling rate), bandpass filtering (0.2–5.0 Hz) to eliminate non-human movement, and signal aggregation to reduce data to simplify visualization and summarization. We examined the consistency of MIMS-units using orbital shaker testing on eight accelerometers with varying dynamic range (±2 to ±8 g) and sampling rates (20–100 Hz), and human data (N = 60) from an ActiGraph GT9X. Results: During shaker testing, MIMS-units yielded lower between-device coefficient of variations than proprietary ActiGraph and ENMO acceleration summaries. Unlike the widely used ActiGraph activity counts, MIMS-units were sensitive in detecting subtle wrist movements during sedentary behaviors. Conclusions: Open-source MIMS-units may provide a means to summarize high-resolution raw data in a device-independent manner, thereby increasing standardization of data cleaning and analytical procedures to estimate selected attributes of physical behavior across studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1123/jmpb.2018-0068

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 211

Metadata

Authors
John, D., Tang, Q., Albinali, F., & Intille, S.
Venue
Journal for the Measurement of Physical Behaviour
Published
2019-12-01
Volume
2
Issue
4
Pages
268-281
ISSN
  • 2575-6605 (ISSN-L)
  • 2575-6613
OpenAlex
W2988085983
Cited by
211
References
14
FWCI
6.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Open-Source Monitor-Independent Movement Summary for Accelerometer Data Processing. https://app.cochat.ai/papers/10.1123/jmpb.2018-0068
The paper
John, D., Tang, Q., Albinali, F., & Intille, S. (2019). An Open-Source Monitor-Independent Movement Summary for Accelerometer Data Processing. Journal for the Measurement of Physical Behaviour. https://doi.org/10.1123/jmpb.2018-0068

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.