The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Microfluidic device for the formation of optically excitable, three-dimensional, compartmentalized motor units
Open accessAbstract
Microfluidics and optogenetics enable the formation of light-excitable motor units in a compartmentalized and 3D environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
DEVELOPMENT OF THE VERTEBRATE NEUROMUSCULAR JUNCTION
Sanes, J. R., & Lichtman, J. W. (1999) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.22.1.389 · Cited by 1,532
Induced pluripotent stem cells from a spinal muscular atrophy patient
Ebert, A. D., Yu, J., Rose, F. F., Mattis, V. B., Lorson, C. L., Thomson, J. A., & Svendsen, C. N. (2009) · Nature · doi:10.1038/nature07677 · Cited by 1,441
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
Neural bases for addictive properties of benzodiazepines
Tan, K. R., Brown, M., Labouèbe, G., Yvon, C., Creton, C., Fritschy, J.-M., Rudolph, U., & Lüscher, C. (2010) · Nature · doi:10.1038/nature08758 · Cited by 397
Juhas, M., Engelmayr, G. C., Fontanella, A. N., Palmer, G. M., & Bursac, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1402723111 · Cited by 246
Hester, M. E., Murtha, M. J., Song, S., Rao, M., Miranda, C. J., Meyer, K., Tian, J., Boulting, G., Schaffer, D. V., Zhu, M. X., et al. (2011) · Molecular Therapy · doi:10.1038/mt.2011.135 · Cited by 183
Optical Control of Muscle Function by Transplantation of Stem Cell–Derived Motor Neurons in Mice
Bryson, J. B., Machado, C. B., Crossley, M., Stevenson, D., Bros-Facer, V., Burrone, J., Greensmith, L., & Lieberam, I. (2014) · Science · doi:10.1126/science.1248523 · Cited by 163
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Osaki, T., Uzel, S. G. M., & Kamm, R. D. (2018) · Science Advances · doi:10.1126/sciadv.aat5847 · Cited by 421
Self-citationVascularized microfluidic organ-chips for drug screening, disease models and tissue engineering
Osaki, T., Sivathanu, V., & Kamm, R. D. (2018) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.03.011 · Cited by 141
Self-citationIntegrating Organs-on-Chips: Multiplexing, Scaling, Vascularization, and Innervation
Park, D., Lee, J., Chung, J. J., Jung, Y., & Kim, S. H. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.06.006 · Cited by 105
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Metadata
- Authors
- Uzel, S. G. M., Platt, R. J., Subramanian, V., Pearl, T. M., Rowlands, C. J., Chan, V., Boyer, L. A., So, P. T. C., & Kamm, R. D.
- Venue
- Science Advances
- Published
- 2016-08-05
- Volume
- 2
- Issue
- 8
- Pages
- e1501429-e1501429
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W2493265938
- Cited by
- 213
- References
- 8
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic device for the formation of optically excitable, three-dimensional, compartmentalized motor units. https://app.cochat.ai/papers/10.1126/sciadv.1501429
- The paper
- Uzel, S. G. M., Platt, R. J., Subramanian, V., Pearl, T. M., Rowlands, C. J., Chan, V., Boyer, L. A., So, P. T. C., & Kamm, R. D. (2016). Microfluidic device for the formation of optically excitable, three-dimensional, compartmentalized motor units. Science Advances. https://doi.org/10.1126/sciadv.1501429
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.