CoChat

Wireless battery-free wearable sweat sensor powered by human motion

Open access

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Abstract

Wireless battery-free wearable sensor powered by human motion is able to analyze sweat biomarkers for personalized health care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aay9842

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Battery-free FWS3 for wireless and noninvasive molecular monitoring. (A) Schematic illustrating the FWS3 that integrates human motion energy harvesting, signal processing, microfluidic-based sweat biosensing, and Bluetooth-based wireless data transmission to a mobile user interface for real-time health status tracking. (B and C) Optical images of an FPCB-based FWS3, which can be worn on a human side torso. Scale bars, 4 cm. (D) Schematic diagram of the FPCB-based FTENG with a grating slider and an interdigital stator. (E) Schematic diagram of the FWS3 showing a microfluidic-based sweat sensor patch interfacing with the flexible circuitry. (F) System-level block diagram showing the power management, signal transduction, processing, and wireless transmission of the FWS3 from the FTENG to the biosensors, then to the user interface. Photo credit: Yu Song, California Institute of Technology.
Fig. 1 Battery-free FWS3 for wireless and noninvasive molecular monitoring. (A) Schematic illustrating the FWS3 that integrates human motion energy harvesting, signal processing, microfluidic-based sweat biosensing, and Bluetooth-based wireless data transmission to a mobile user interface for real-time health status tracking. (B and C) Optical images of an FPCB-based FWS3, which can be worn on a human side torso. Scale bars, 4 cm. (D) Schematic diagram of the FPCB-based FTENG with a grating slider and an interdigital stator. (E) Schematic diagram of the FWS3 showing a microfluidic-based sweat sensor patch interfacing with the flexible circuitry. (F) System-level block diagram showing the power management, signal transduction, processing, and wireless transmission of the FWS3 from the FTENG to the biosensors, then to the user interface. Photo credit: Yu Song, California Institute of Technology.CC BY-NC · PubMed Central
Fig. 2 Characterization of the FTENG for energy harvesting from human motion. (A) Schematic illustration of the working mechanism and charge distribution of the FTENG. (B) Microscopic and optical images of an FPCB-based interdigital stator with an ENIG surface finish on the patterned electrode area. Scale bars, 200 μm and 5 mm. (C) Current output of an FTENG under different working frequencies. (D) Peak voltage and the corresponding average power of an FTENG at different external load resistances (n = 5). Working frequency, 1.5 Hz. (E) Durability of M-PDMS–, W-PDMS–, and PTFE-based stators after 20,000 test cycles. V and V0 represent the peak open-circuit voltage after and before the durability test. Inset images, SEM images of M-PDMS, W-PDMS, and PTFE after 20,000 test cycles. Scale bars, 5, 50, and 50 μm. (F) Schematic of the flexible FTENG with different stator layouts (one, three, or six panels in parallel) and corresponding slider layouts. (G) Comparison of voltages of the capacitors ranging from 10 to 1000 μF charged with one-, three-, and six-panel FTENGs for 30 cycles. (H) Long-term stability of a three-panel FTENG in charging a 47-μF capacitor under a working frequency of 1.5 Hz for 2 hours.
Fig. 2 Characterization of the FTENG for energy harvesting from human motion. (A) Schematic illustration of the working mechanism and charge distribution of the FTENG. (B) Microscopic and optical images of an FPCB-based interdigital stator with an ENIG surface finish on the patterned electrode area. Scale bars, 200 μm and 5 mm. (C) Current output of an FTENG under different working frequencies. (D) Peak voltage and the corresponding average power of an FTENG at different external load resistances (n = 5). Working frequency, 1.5 Hz. (E) Durability of M-PDMS–, W-PDMS–, and PTFE-based stators after 20,000 test cycles. V and V0 represent the peak open-circuit voltage after and before the durability test. Inset images, SEM images of M-PDMS, W-PDMS, and PTFE after 20,000 test cycles. Scale bars, 5, 50, and 50 μm. (F) Schematic of the flexible FTENG with different stator layouts (one, three, or six panels in parallel) and corresponding slider layouts. (G) Comparison of voltages of the capacitors ranging from 10 to 1000 μF charged with one-, three-, and six-panel FTENGs for 30 cycles. (H) Long-term stability of a three-panel FTENG in charging a 47-μF capacitor under a working frequency of 1.5 Hz for 2 hours.CC BY-NC · PubMed Central
Fig. 3 Characterization of the microfluidic-based biosensor patch in vitro. (A) Schematic of a flexible biosensor array containing a pH sensor and a Na+ sensor patterned on a flexible PET substrate. (B and C) Open-circuit potential responses of a pH sensor in standard Mcllvaine’s buffer solutions (B) and a Na+ sensor in NaCl solutions (C). Insets show the corresponding calibration plots of each sensor. Error bars represent the SDs from six independent tests. (D) Schematic of the microfluidic design for dynamic sweat sampling. M-tape, medical tape. (E) Dynamic response of a Na+ sensor under different flow rates upon switching the solution concentrations. (F) Repeatability of dynamic response of a Na+ sensor by continuously switching the inflow solutions at a flow rate of 2 μl min−1. (G) Schematic of microfluidic sensor patch conformally attached to human skin. Inset image, optical image of a microfluidic sensor patch under mechanical deformation. Scale bar, 5 mm. (H and I) Responses of a Na+ and pH sensor array after 0, 200, and 400 cycles of bending (H) and during bending states (I) (radius of curvature, 2 cm). Data recording was paused for 30 s to change the conditions and settings. Photo credit: Yu Song, California Institute of Technology.
Fig. 3 Characterization of the microfluidic-based biosensor patch in vitro. (A) Schematic of a flexible biosensor array containing a pH sensor and a Na+ sensor patterned on a flexible PET substrate. (B and C) Open-circuit potential responses of a pH sensor in standard Mcllvaine’s buffer solutions (B) and a Na+ sensor in NaCl solutions (C). Insets show the corresponding calibration plots of each sensor. Error bars represent the SDs from six independent tests. (D) Schematic of the microfluidic design for dynamic sweat sampling. M-tape, medical tape. (E) Dynamic response of a Na+ sensor under different flow rates upon switching the solution concentrations. (F) Repeatability of dynamic response of a Na+ sensor by continuously switching the inflow solutions at a flow rate of 2 μl min−1. (G) Schematic of microfluidic sensor patch conformally attached to human skin. Inset image, optical image of a microfluidic sensor patch under mechanical deformation. Scale bar, 5 mm. (H and I) Responses of a Na+ and pH sensor array after 0, 200, and 400 cycles of bending (H) and during bending states (I) (radius of curvature, 2 cm). Data recording was paused for 30 s to change the conditions and settings. Photo credit: Yu Song, California Institute of Technology.CC BY-NC · PubMed Central
Fig. 4 System-level integration and evaluation of the FWS3. (A) Schematic diagram of the battery-free FWS3 consisting of an FTENG module, a biosensor interface, instrumentation amplifiers, an energy harvesting PMIC, a voltage regulator, and a BLE PSoC module. (B) Operation flow of the FWS3 with signal processing and data transmission. (C) Power consumption of the FWS3 during the operation. (D) Real-time potential of the capacitor (242 μF) during the continuous operation of the FWS3 with a three-panel FTENG under different working frequencies. (E) Validation of data transmission from an FWS3 with a three-panel FTENG under different working frequencies. (F) Long-term stability of the capacitor charging process when an FWS3 operates under a working frequency of 1.5 Hz. (G) Sensor responses in a collected human sweat sample when an FWS3 operates under a working frequency of 1.5 Hz.
Fig. 4 System-level integration and evaluation of the FWS3. (A) Schematic diagram of the battery-free FWS3 consisting of an FTENG module, a biosensor interface, instrumentation amplifiers, an energy harvesting PMIC, a voltage regulator, and a BLE PSoC module. (B) Operation flow of the FWS3 with signal processing and data transmission. (C) Power consumption of the FWS3 during the operation. (D) Real-time potential of the capacitor (242 μF) during the continuous operation of the FWS3 with a three-panel FTENG under different working frequencies. (E) Validation of data transmission from an FWS3 with a three-panel FTENG under different working frequencies. (F) Long-term stability of the capacitor charging process when an FWS3 operates under a working frequency of 1.5 Hz. (G) Sensor responses in a collected human sweat sample when an FWS3 operates under a working frequency of 1.5 Hz.CC BY-NC · PubMed Central
Fig. 5 On-body evaluation of the FWS3 for wireless, dynamic perspiration analysis. (A) Output waveforms of a six-panel FPCB-based FTENG during various exercises. (B and C) Real-time potential of the capacitor charged by an FTENG (B) and the average charging time for each package transmission (C) when a subject is running on a treadmill for 1 hour at a constant speed of 9 km hour−1. The ratio in (C) represents the percentage of charging cycles (with charging duration within a given time range) out of all the charging cycles. When the potential reaches 3.3 V, the capacitor is discharged due to the BLE data transmission. (D) Optical image of a subject on a treadmill wearing an FWS3 and a mobile phone. (E) Real-time sweat pH and Na+ levels wirelessly obtained from the wearable systems charged by a lithium battery and by an FTENG during constant speed running. Photo credit: Yu Song, California Institute of Technology.
Fig. 5 On-body evaluation of the FWS3 for wireless, dynamic perspiration analysis. (A) Output waveforms of a six-panel FPCB-based FTENG during various exercises. (B and C) Real-time potential of the capacitor charged by an FTENG (B) and the average charging time for each package transmission (C) when a subject is running on a treadmill for 1 hour at a constant speed of 9 km hour−1. The ratio in (C) represents the percentage of charging cycles (with charging duration within a given time range) out of all the charging cycles. When the potential reaches 3.3 V, the capacitor is discharged due to the BLE data transmission. (D) Optical image of a subject on a treadmill wearing an FWS3 and a mobile phone. (E) Real-time sweat pH and Na+ levels wirelessly obtained from the wearable systems charged by a lithium battery and by an FTENG during constant speed running. Photo credit: Yu Song, California Institute of Technology.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 652

Metadata

Authors
Song, Y., Min, J., Yu, Y., Wang, H., Yang, Y., Zhang, H., & Gao, W.
Affiliations
  • California Institute of Technology (US)
  • Peking University (CN)
Corresponding author
Gao, Wei
Venue
Science Advances
Published
2020-10-02
Volume
6
Issue
40
ISSN
2375-2548 (ISSN-L)
OpenAlex
W3089560203
Cited by
652
References
56
Citations by year
2026: 79 · 2025: 113 · 2024: 107 · 2023: 133 · 2022: 122 · 2021: 93 · 2020: 5
FWCI
27.73
Type
journal article
Language
en
Open access
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion, cc-by-nc)
Funders
  • California Institute of Technology
  • The Translational Research Institute for Space Health (NASA NNX16AO69A)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
battery-free sensors, wearable sensors, triboelectric energy harvesting, human motion energy, wireless data transmission, Bluetooth, power management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.