Shell microelectrode arrays (MEAs) for brain organoids
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Brain organoids are important models for mimicking some three-dimensional (3D) cytoarchitectural and functional aspects of the brain. Multielectrode arrays (MEAs) that enable recording and stimulation of activity from electrogenic cells offer notable potential for interrogating brain organoids. However, conventional MEAs, initially designed for monolayer cultures, offer limited recording contact area restricted to the bottom of the 3D organoids. Inspired by the shape of electroencephalography caps, we developed miniaturized wafer-integrated MEA caps for organoids. The optically transparent shells are composed of self-folding polymer leaflets with conductive polymer–coated metal electrodes. Tunable folding of the minicaps’ polymer leaflets guided by mechanics simulations enables versatile recording from organoids of different sizes, and we validate the feasibility of electrophysiology recording from 400- to 600-μm-sized organoids for up to 4 weeks and in response to glutamate stimulation. Our studies suggest that 3D shell MEAs offer great potential for high signal-to-noise ratio and 3D spatiotemporal brain organoid recording.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebral organoids model human brain development and microcephaly
Lancaster, M. A., Renner, M., Martin, C.-A., Wenzel, D., Bicknell, L. S., Hurles, M. E., Homfray, T., Penninger, J. M., Jackson, A. P., & Knoblich, J. A. (2013) · Nature · doi:10.1038/nature12517 · Cited by 5,372
Functional cortical neurons and astrocytes from human pluripotent stem cells in 3D culture
Paşca, A. M., Sloan, S. A., Clarke, L. E., Tian, Y., Makinson, C. D., Huber, N., Kim, C. H., Park, J.-Y., O'Rourke, N. A., Nguyen, K. D., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3415 · Cited by 1,609
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Trujillo, C. A., Gao, R., Negraes, P. D., Gu, J., Buchanan, J., Preissl, S., Wang, A., Wu, W., Haddad, G. G., Chaim, I. A., et al. (2019) · Cell Stem Cell · doi:10.1016/j.stem.2019.08.002 · Cited by 974 · cited 1×
“However, traditional in vitro MEA plates use predominantly planar electrode interfaces, initially designed for monolayer cultures, thus limiting the contact surface area with 3D organoids (3, 15).”
BackgroundEngineering of human brain organoids with a functional vascular-like system
Cakir, B., Xiang, Y., Tanaka, Y., Kural, M. H., Parent, M., Kang, Y.-J., Chapeton, K., Patterson, B., Yuan, Y., He, C.-S., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0586-5 · Cited by 942
The use of brain organoids to investigate neural development and disease
Di Lullo, E., & Kriegstein, A. R. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2017.107 · Cited by 788
Spike sorting for large, dense electrode arrays
Rossant, C., Kadir, S. N., Goodman, D. F. M., Schulman, J., Hunter, M. L. D., Saleem, A. B., Grosmark, A., Belluscio, M., Denfield, G. H., Ecker, A. S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4268 · Cited by 785
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Robinson, J. T., Jorgolli, M., Shalek, A. K., Yoon, M.-H., Gertner, R. S., & Park, H. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.249 · Cited by 600 · cited 1×
“For example, spineshaped gold electrodes have been used to reduce the extracellular cleft for a better signal-to-noise ratio (SNR) (16), and vertical nanowires provide recording access to the interior of the measured cell via penetration (17).”
MethodA miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543
Past, present and future of spike sorting techniques
Rey, H. G., Pedreira, C., & Quian Quiroga, R. (2015) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2015.04.007 · Cited by 462 · cited 1×
“4D) shows the recording of the spontaneous activity of the enveloped brain organoid (35, 36).”
BackgroundCho, A.-N., Jin, Y., An, Y., Kim, J., Choi, Y. S., Lee, J. S., Kim, J., Choi, W.-Y., Koo, D.-J., Yu, W., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24775-5 · Cited by 397
High-throughput automated organoid culture via stem-cell aggregation in microcavity arrays
Brandenberg, N., Hoehnel, S., Kuttler, F., Homicsko, K., Ceroni, C., Ringel, T., Gjorevski, N., Schwank, G., Coukos, G., Turcatti, G., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0565-2 · Cited by 390
Bandyopadhyay, A., Valavala, P. K., Clancy, T. C., Wise, K. E., & Odegard, G. M. (2011) · Polymer · doi:10.1016/j.polymer.2011.03.052 · Cited by 381
Brain organoids for the study of human neurobiology at the interface of in vitro and in vivo
Chiaradia, I., & Lancaster, M. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00730-3 · Cited by 348
Transformer Hydrogels: A Review
Erol, O., Pantula, A., Liu, W., & Gracias, D. H. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900043 · Cited by 293
Self-citationPark, Y., Franz, C. K., Ryu, H., Luan, H., Cotton, K. Y., Kim, J. U., Chung, T. S., Zhao, S., Vazquez-Guardado, A., Yang, D. S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abf9153 · Cited by 280
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
In vitro and in vivo evaluation of SU-8 biocompatibility
Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.07.001 · Cited by 262
Pamies, D. (2017) · ALTEX · doi:10.14573/altex.1609122 · Cited by 250 · cited 4×
“National Institute for Biological Standards and Control (NIBSC)], following our in-house two-step protocol (8).”
BackgroundMethodInfluentialKalmykov, A., Huang, C., Bliley, J., Shiwarski, D., Tashman, J., Abdullah, A., Rastogi, S. K., Shukla, S., Mataev, E., Feinberg, A. W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aax0729 · Cited by 233
Marx, U. (2020) · ALTEX · doi:10.14573/altex.2001241 · Cited by 218
Renner, H., Grabos, M., Becker, K. J., Kagermeier, T. E., Wu, J., Otto, M., Peischard, S., Zeuschner, D., TsyTsyura, Y., Disse, P., et al. (2020) · eLife · doi:10.7554/elife.52904 · Cited by 215
Relation of elastic modulus to crosslink and entanglement concentrations in rubber networks
Langley, N. R., & Polmanteer, K. E. (1974) · Journal of Polymer Science Polymer Physics Edition · doi:10.1002/pol.1974.180120601 · Cited by 182
A flexible 3-dimensional microelectrode array for in vitro brain models
Soscia, D. A., Lam, D., Tooker, A. C., Enright, H. A., Triplett, M., Karande, P., Peters, S. K. G., Sales, A. P., Wheeler, E. K., & Fischer, N. O. (2020) · Lab on a Chip · doi:10.1039/c9lc01148j · Cited by 179 · cited 1×
“Recently, several curved and folded shapes have been introduced for MEA recording, including buckled, cylindrical, and shells (20-26).”
Thoughts on limitations of animal models
Härtung, T. (2008) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2008.04.003 · Cited by 166
Le Floch, P., Li, Q., Lin, Z., Zhao, S., Liu, R., Tasnim, K., Jiang, H., & Liu, J. (2022) · Advanced Materials · doi:10.1002/adma.202106829 · Cited by 161
Hai, A., Dormann, A., Shappir, J., Yitzchaik, S., Bartic, C., Borghs, G., Langedijk, J. P. M., & Spira, M. E. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0087 · Cited by 142 · cited 4×
“The signal-to-noise ratio (SNR) of the same spikes in the 3D shell electrodes channels was significantly higher (yielding a 42% increase in the median, p 0.005) than in the 2D channels (Fig.”
MethodInfluentialLin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133
Liu, Y., McGuire, A. F., Lou, H.-Y., Li, T. L., Tok, J. B. ‐., Cui, B., & Bao, Z. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1810827115 · Cited by 132 · cited 1×
“We added a conductive polymer PEDOT: PSS coating on the electrode to reduce impedance and modulus for the MEAs/organoid contact (19, 31) (Fig.”
MethodDoes Impedance Matter When Recording Spikes With Polytrodes?
Neto, J. P., Baião, P., Lopes, G., Frazão, J., Nogueira, J., Fortunato, E., Barquinha, P., & Kampff, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00715 · Cited by 103
Automatic Analysis of EEGs Using Big Data and Hybrid Deep Learning Architectures
Golmohammadi, M., Harati Nejad Torbati, A. H., Lopez de Diego, S., Obeid, I., & Picone, J. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00076 · Cited by 101 · cited 2×
“AI-based analysis methods of human EEGs (42, 43) lend themselves for the analysis of such recordings.”
MethodHigh-throughput screening of human induced pluripotent stem cell-derived brain organoids
Durens, M., Nestor, J. E., Williams, M., Herold, K., Niescier, R. F., Lunden, J. W., Phillips, A. W., Lin, Y., Dykxhoorn, D. M., & Nestor, M. W. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108627 · Cited by 95
Human microphysiological systems for drug development
Roth, A., & 2019, M.-W. B. (2021) · Science · doi:10.1126/science.abc3734 · Cited by 94
Modafferi, S., Zhong, X., Kleensang, A., Murata, Y., Fagiani, F., Pamies, D., Hogberg, H. T., Calabrese, V., Lachman, H., Hartung, T., et al. (2021) · Environmental Health Perspectives · doi:10.1289/ehp8580 · Cited by 86
Self-citationA Micropatterned Multielectrode Shell for 3D Spatiotemporal Recording from Live Cells
Cools, J., Jin, Q., Yoon, E. J., Burbano, D. A., Luo, Z., Cuypers, D., Callewaert, G., Braeken, D., & Gracias, D. H. (2018) · Advanced Science · doi:10.1002/advs.201700731 · Cited by 71
Self-citationAdvances in 3D neuronal microphysiological systems: towards a functional nervous system on a chip
Anderson, W. A., Bosak, A. J., Högberg, H. T., Härtung, T., & Moore, M. J. (2021) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-020-00532-8 · Cited by 70
Human IPSC-Derived Model to Study Myelin Disruption
Chesnut, M., Paschoud, H., Repond, C., Smirnova, L., Hartung, T., Zurich, M.-G., Hogberg, H. T., & Pamies, D. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22179473 · Cited by 48
Self-citationBioelectrical interfaces with cortical spheroids in three-dimensions
Kalmykov, A., Reddy, J. W., Bedoyan, E., Wang, Y., Garg, R., Rastogi, S. K., Cohen-Karni, D., Chamanzar, M., & Cohen‐Karni, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf290 · Cited by 36
Human Oligodendrocytes and Myelin In Vitro to Evaluate Developmental Neurotoxicity
Chesnut, M., Hartung, T., Hogberg, H., & Pamies, D. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22157929 · Cited by 29 · cited 1×
“Oligodendrocytes provide myelin sheaths around the axons, which reduce the ion leakage and capacitance of the cell membrane for efficient electrical signal transmission (32, 33).”
BackgroundSelf-citationThree dimensional bioelectronic interfaces to small-scale biological systems
Park, Y., Chung, T. S., & Rogers, J. A. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.07.023 · Cited by 27
Antonijević, M., Zivkovic, M. Z., Arsic, S., & Jevremović, A. (2020) · Journal of Sensors · doi:10.1155/2020/8767865 · Cited by 23
Solvent Responsive Self‐Folding of 3D Photosensitive Graphene Architectures
Huang, Q., Deng, T., Xu, W., Yoon, C., Zhao Qin, A., Lin, Y., Li, T., Yang, Y., Shen, M., Thon, S. M., et al. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000195 · Cited by 17
Self-citationHan, Y. F., Zhu, H., Zhao, Y., Lang, Y., Sun, H., Han, J., Wang, L., Wang, C., & Zhou, J. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.07.007 · Cited by 11 · cited 2×
“Since glutamate is known to increase neural activity (37), we investigated whether 3D or 2D electrodes are more sensitive to glutamate-mediated changes.”
BackgroundHTsort: Enabling Fast and Accurate Spike Sorting on Multi-Electrode Arrays
Chen, K., Jiang, Y., Wu, Z., Zheng, N., Wang, H., & Hong, H. (2021) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2021.657151 · Cited by 8 · cited 1×
“This was done by treating spikes with peak times differing less than 2 ms (one waveform length) as the same spike, and hence summarizing them as one single spike with maximum normalized amplitude (45, 46).”
Method
Cited by
Brain organoid reservoir computing for artificial intelligence
Cai, H., Ao, Z., Tian, C., Wu, Z., Liu, H., Tchieu, J., Gu, M., Mackie, K., & Guo, F. (2023) · Nature Electronics · doi:10.1038/s41928-023-01069-w · Cited by 277
Organoid intelligence (OI): the new frontier in biocomputing and intelligence-in-a-dish
Smirnova, L., Caffo, B. S., Gracias, D. H., Huang, Q., Morales Pantoja, I. E., Tang, B., Zack, D. J., Berlinicke, C. A., Boyd, J. L., Harris, T. D., et al. (2023) · Frontiers in Science · doi:10.3389/fsci.2023.1017235 · Cited by 276
Self-citationMechanically-Guided 3D Assembly for Architected Flexible Electronics
Bo, R., Xu, S., Yang, Y., & Zhang, Y. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00335 · Cited by 164
Self-citationPamies, D., Ekert, J., Zurich, M.-G., Frey, O., Werner, S., Piergiovanni, M., Freedman, B. S., Keong Teo, A. K., Erfurth, H., Reyes, D. R., et al. (2024) · Stem Cell Reports · doi:10.1016/j.stemcr.2024.03.009 · Cited by 88
Self-citationRodrigues, R. O., Shin, S.-R., & Bañobre-López, M. (2024) · Journal of Nanobiotechnology · doi:10.1186/s12951-024-02720-0 · Cited by 44
“Example of this feature is the work of Huang et al. 2022 [113], which proposed a 3D shell MEA composed of self-folding polymer leaflets with conductive polymer–coated metal electrodes, reporting great potential for high signal-to-noise ratio and 3D spatiotemporal brain organoid recording.”
BackgroundMethodInfluential
Metadata
- Authors
- Huang, Q., Tang, B., Romero, J. C., Yang, Y., Elsayed, S. K., Pahapale, G., Lee, T.-J., Morales Pantoja, I. E., Han, F., Berlinicke, C., Xiang, T., Solazzo, M., Hartung, T., Qin, Z., Caffo, B. S., Smirnova, L., & Gracias, D. H.
- Venue
- Science Advances
- Published
- 2022-08-19
- Volume
- 8
- Issue
- 33
- Pages
- eabq5031-eabq5031
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W4292116816
- Cited by
- 202
- References
- 47
- FWCI
- 13.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.