The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Microfluidic Bubble Logic
Abstract
We demonstrate universal computation in an all-fluidic two-phase microfluidic system. Nonlinearity is introduced into an otherwise linear, reversible, low–Reynolds number flow via bubble-to-bubble hydrodynamic interactions. A bubble traveling in a channel represents a bit, providing us with the capability to simultaneously transport materials and perform logical control operations. We demonstrate bubble logic AND/OR/NOT gates, a toggle flip-flop, a ripple counter, timing restoration, a ring oscillator, and an electro–bubble modulator. These show the nonlinearity, gain, bistability, synchronization, cascadability, feedback, and programmability required for scalable universal computation. With increasing complexity in large-scale microfluidic processors, bubble logic provides an on-chip process control mechanism integrating chemistry and computation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
The motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Fredkin, E., & Toffoli, T. (1982) · International Journal of Theoretical Physics · doi:10.1007/bf01857727 · Cited by 1,896
Enzyme-Free Nucleic Acid Logic Circuits
Seelig, G., Soloveichik, D., Zhang, D. Y., & Winfree, E. (2006) · Science · doi:10.1126/science.1132493 · Cited by 1,540
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Electric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 841
Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Long-Term Monitoring of Bacteria Undergoing Programmed Population Control in a Microchemostat
Balagaddé, F. K., You, L., Hansen, C. L., Arnold, F. H., & Quake, S. R. (2005) · Science · doi:10.1126/science.1109173 · Cited by 599
Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics
Lee, C.-C., Sui, G., Elizarov, A., Shu, C. J., Shin, Y.-S., Dooley, A. N., Huang, J., Daridon, A., Wyatt, P., Stout, D., et al. (2005) · Science · doi:10.1126/science.1118919 · Cited by 510
Tan, Y.-C., Fisher, J. S., Lee, A. I., Cristini, V., & Lee, A. P. (2004) · Lab on a Chip · doi:10.1039/b403280m · Cited by 509
Droplet Control for Microfluidics
Joanicot, M., & Ajdari, A. (2005) · Science · doi:10.1126/science.1112615 · Cited by 379
Steinbock, O., Kettunen, P., & Showalter, K. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961209v · Cited by 220
A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers
Groisman, A., & Quake, S. R. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.094501 · Cited by 202
He, M., Kuo, J. S., & Chiu, D. T. (2005) · Applied Physics Letters · doi:10.1063/1.1997280 · Cited by 90
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
An integrated design and fabrication strategy for entirely soft, autonomous robots
Wehner, M., Truby, R. L., Fitzgerald, D. J., Mosadegh, B., Whitesides, G. M., Lewis, J. A., & Wood, R. J. (2016) · Nature · doi:10.1038/nature19100 · Cited by 2,127
Dynamics of microfluidic droplets
Baroud, C. N., Gallaire, F., & Dangla, R. (2010) · Lab on a Chip · doi:10.1039/c001191f · Cited by 1,067
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Metadata
- Authors
- Prakash, M., & Gershenfeld, N.
- Venue
- Science
- Published
- 2007-02-09
- Volume
- 315
- Issue
- 5813
- Pages
- 832-835
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1984050685
- Cited by
- 511
- References
- 17
- FWCI
- 29.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.