The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Video-Rate Far-Field Optical Nanoscopy Dissects Synaptic Vesicle Movement
Open accessAbstract
We present video-rate (28 frames per second) far-field optical imaging with a focal spot size of 62 nanometers in living cells. Fluorescently labeled synaptic vesicles inside the axons of cultured neurons were recorded with stimulated emission depletion (STED) microscopy in a 2.5-micrometer by 1.8-micrometer field of view. By reducing the cross-sectional area of the focal spot by about a factor of 18 below the diffraction limit (260 nanometers), STED allowed us to map and describe the vesicle mobility within the highly confined space of synaptic boutons. Although restricted within boutons, the vesicle movement was substantially faster in nonbouton areas, consistent with the observation that a sizable vesicle pool continuously transits through the axons. Our study demonstrates the emerging ability of optical microscopy to investigate intracellular physiological processes on the nanoscale in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationUltra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Self-citationSüdhof, T. C. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.26.041002.131412 · Cited by 2,547
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
STED microscopy reveals that synaptotagmin remains clustered after synaptic vesicle exocytosis
Willig, K. I., Rizzoli, S. O., Westphal, V., Jahn, R., & Hell, S. W. (2006) · Nature · doi:10.1038/nature04592 · Cited by 1,225
Self-citationQuantitative ultrastructural analysis of hippocampal excitatory synapses
Schikorski, T., & Stevens, C. F. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-15-05858.1997 · Cited by 997
Rizzoli, S. O., & Betz, W. J. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1583 · Cited by 975
Self-citationProperties of a 4Pi confocal fluorescence microscope
Hell, S., & Stelzer, E. H. K. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.002159 · Cited by 560
Self-citationMacromolecular-scale resolution in biological fluorescence microscopy
Donnert, G., Keller, J., Medda, R., Andrei, M. A., Rizzoli, S. O., Lührmann, R., Jahn, R., Eggeling, C., & Hell, S. W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604965103 · Cited by 527
Self-citationSTED microscopy with continuous wave beams
Willig, K. I., Harke, B., Medda, R., & Hell, S. W. (2007) · Nature Methods · doi:10.1038/nmeth1108 · Cited by 523
Self-citationThree modes of synaptic vesicular recycling revealed by single-vesicle imaging
Gandhi, S. P., & Stevens, C. F. (2003) · Nature · doi:10.1038/nature01677 · Cited by 449
Single synaptic vesicles fusing transiently and successively without loss of identity
Aravanis, A. M., Pyle, J. L., & Tsien, R. W. (2003) · Nature · doi:10.1038/nature01686 · Cited by 399
Two-Color Far-Field Fluorescence Nanoscopy
Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104497 · Cited by 256
Self-citationConstitutive sharing of recycling synaptic vesicles between presynaptic boutons
Darcy, K. J., Staras, K., Collinson, L. M., & Goda, Y. (2006) · Nature Neuroscience · doi:10.1038/nn1640 · Cited by 216
Kiss‐and‐run, Collapse and ‘Readily Retrievable’ Vesicles
Rizzoli, S. O., & Jahn, R. (2007) · Traffic · doi:10.1111/j.1600-0854.2007.00614.x · Cited by 134
Self-citationGaffield, M. A., Rizzoli, S. O., & Betz, W. J. (2006) · Neuron · doi:10.1016/j.neuron.2006.06.031 · Cited by 111
Self-citationKraszewski, K., DANIELL, L. W., Mundigl, O., & Camilli, P. V. D. (1996) · Journal of Neuroscience · doi:10.1523/jneurosci.16-19-05905.1996 · Cited by 105
Henkel, A. W., Simpson, L. L., Ridge, R. M., & Betz, W. J. (1996) · Journal of Neuroscience · doi:10.1523/jneurosci.16-12-03960.1996 · Cited by 101
Jordan, R., Lemke, E. A., & Klingauf, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061663 · Cited by 89
Direct Observation of Collective Blinking and Energy Transfer in a Bichromophoric System
Tinnefeld, P., Buschmann, V., Weston, K. D., & Sauer, M. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp026565u · Cited by 69
Probing vesicle dynamics in single hippocampal synapses.
Shtrahman, M., Yeung, C., Nauen, D. W., Bi, G., & Wu, X.-L. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.059295 · Cited by 68
Lemke, E. A., & Klingauf, J. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.2971-05.2005 · Cited by 59
Dynamic far-field fluorescence nanoscopy
Westphal, V., Lauterbach, M. A., Nicola, A. D., & Hell, S. W. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/12/435 · Cited by 57
Self-citationStick-and-Diffuse and Caged Diffusion: A Comparison of Two Models of Synaptic Vesicle Dynamics
Yeung, C., Shtrahman, M., & Wu, X.-L. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.081794 · Cited by 43
Cited by
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Fluorescent probes for super-resolution imaging in living cells
Fernández-Suárez, M., & Ting, A. Y. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2531 · Cited by 1,306
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Metadata
- Authors
- Westphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., Jahn, R., & Hell, S. W.
- Venue
- Science
- Published
- 2008-04-11
- Volume
- 320
- Issue
- 5873
- Pages
- 246-249
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2013669507
- Cited by
- 788
- References
- 27
- FWCI
- 35.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.