The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Putting Electrowetting to Work
Abstract
Voltage pulses that cause changes in fluid shape or movement can be used to drive optical components and miniaturized assays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, X.-M., Reinhoudt, D., & Crego-Calama, M. (2007) · Chemical Society Reviews · doi:10.1039/b602486f · Cited by 2,079
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Electrowetting and electrowetting-on-dielectric for microscale liquid handling
Lee, J., Moon, H., Fowler, J., Schoellhammer, T., & Kim, C.-J. (2002) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00734-8 · Cited by 652
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Self-citationIntegrated polymerase chain reaction chips utilizing digital microfluidics
Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8171-y · Cited by 324
Pluronic Additives: A Solution to Sticky Problems in Digital Microfluidics
Luk, V. N., Mo, G. C., & Wheeler, A. R. (2008) · Langmuir · doi:10.1021/la7039509 · Cited by 227
Self-citationAbdelgawad, M., Freire, S. L. S., Yang, H., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b801516c · Cited by 188
Self-citationA Digital Microfluidic Approach to Homogeneous Enzyme Assays
Miller, E. M., & Wheeler, A. R. (2008) · Analytical Chemistry · doi:10.1021/ac702269d · Cited by 167
Self-citationFan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H. (2008) · Lab on a Chip · doi:10.1039/b803204a · Cited by 167
DNA ligation of ultramicro volume using an EWOD microfluidic system with coplanar electrodes
Liu, Y.-J., Yao, D., Lin, H.-C., Chang, W.-Y., & Chang, H. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/4/045017 · Cited by 70
Cited by
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143028 · Cited by 817
Self-citationElectrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Self-citationDroplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Self-citation
Metadata
- Authors
- Wheeler, A. R.
- Venue
- Science
- Published
- 2008-10-24
- Volume
- 322
- Issue
- 5901
- Pages
- 539-540
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1522568210
- Cited by
- 315
- References
- 11
- FWCI
- 18.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.