The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Open accessAbstract
Nanoprobes of Cell Potential: Direct electrical measurements of cell potentials usually face design compromises. Microelectrodes probe within the cytosol of cells but have a minimum size (hundreds of nanometers in width) for obtaining useful signals. Nanoscale field effect transistors (FETs) can have an active probe size of only tens of nanometers but generally allow only the outer cell potential to be measured. Tian et al. (p. 830 ) fabricated nanowires in which kinks could be introduced to create a sharp probe tip pointing away from the fabrication substrate. Coating the tip with a phospholipid bilayer allowed the probe to be inserted through the membranes of beating cardiac cells, where it could be used to follow temporal changes in cell potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac excitation–contraction coupling
Bers, D. M. (2002) · Nature · doi:10.1038/415198a · Cited by 4,744
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Claycomb, W. C., Lanson, N. A., Stallworth, B. S., Egeland, D. B., Delcarpio, J. B., Bahinski, A., & Izzo, N. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.2979 · Cited by 1,546
Nanoelectronics from the bottom up
Lu, W., & Lieber, C. M. (2007) · Nature Materials · doi:10.1038/nmat2028 · Cited by 1,545
Self-citationMicrotubule assembly, organization and dynamics in axons and dendrites
Conde, C., & Cáceres, A. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2631 · Cited by 1,086
Chernomordik, L. V., & Kozlov, M. M. (2008) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1455 · Cited by 1,037
Patch Clamp Techniques for Studying Ionic Channels in Excitable Membranes
Sakmann, B., & Neher, E. (1984) · Annual Review of Physiology · doi:10.1146/annurev.ph.46.030184.002323 · Cited by 755
Drivers of biodiagnostic development
Giljohann, D. A., & Mirkin, C. A. (2009) · Nature · doi:10.1038/nature08605 · Cited by 749
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
VSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618
Silicon Device Scaling to the Sub-10-nm Regime
Ieong, M., Doris, B. B., Kedzierski, J. T., Rim, K., & Yang, M. (2004) · Science · doi:10.1126/science.1100731 · Cited by 573
Electrophysiology in the age of light
Scanziani, M., & Häusser, M. (2009) · Nature · doi:10.1038/nature08540 · Cited by 468
Probing Cellular Chemistry in Biological Systems with Microelectrodes
Wightman, R. M. (2006) · Science · doi:10.1126/science.1120027 · Cited by 439
Tetherless thermobiochemically actuated microgrippers
Leong, T. G., Randall, C. L., Benson, B. R., Bassik, N., Stern, G. M., & Gracias, D. H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807698106 · Cited by 433
Single-crystalline kinked semiconductor nanowire superstructures
Tian, B., Xie, P., Kempa, T. J., Bell, D. C., & Lieber, C. M. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.304 · Cited by 374
Self-citationFlexible electrical recording from cells using nanowire transistor arrays
Cohen-Karni, T., Timko, B. P., Weiss, L. E., & Lieber, C. M. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902752106 · Cited by 218
Self-citationMicroelectrode methods for intracellular recording and ionophoresis
Purves, R. D. (1981) · Academic Press eBooks · Cited by 207
Nanowire transistor arrays for mapping neural circuits in acute brain slices
Qing, Q., Pal, S. K., Tian, B., Duan, X., Timko, B. P., Cohen-Karni, T., Murthy, V. N., & Lieber, C. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914737107 · Cited by 197
Self-citationPatch clamping : an introductory guide to patch clamp electrophysiology
Molleman, A. (2003) · Medical Entomology and Zoology · Cited by 174
Supported lipid bilayer/carbon nanotube hybrids
Zhou, X., Moran-Mirabal, J. M., Craighead, H. G., & McEuen, P. L. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.34 · Cited by 163
Bioelectronic silicon nanowire devices using functional membrane proteins
Misra, N., Martinez, J. A., Huang, S.-C. J., Wang, Y., Stroeve, P., Grigoropoulos, C. P., & Noy, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904850106 · Cited by 161
Cell Electrophysiology with Carbon Nanopipettes
Schrlau, M. G., Dun, N. J., & Bau, H. H. (2009) · ACS Nano · doi:10.1021/nn800851d · Cited by 110
Fusion of biomimetic stealth probes into lipid bilayer cores
Almquist, B. D., & Melosh, N. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909250107 · Cited by 101
Analytical chemistry in microenvironments: single nerve cells
Ewing, A. G., Strein, T. G., & Lau, Y. Y. (1992) · Accounts of Chemical Research · doi:10.1021/ar00022a002 · Cited by 79
Action potentials of HL-1 cells recorded with silicon nanowire transistors
Eschermann, J. F., Stockmann, R., Hueske, M., Vu, X. T., Ingebrandt, S., & Offenhäusser, A. (2009) · Applied Physics Letters · doi:10.1063/1.3194138 · Cited by 69
Molleman, A. (2002) · Wiley eBooks · doi:10.1002/0470856521 · Cited by 68
Probing Macrophage Activity with Carbon‐Nanotube Sensors
Heller, I., Smaal, W. T. T., Lemay, S. G., & Dekker, C. (2009) · Small · doi:10.1002/smll.200900823 · Cited by 28
Cited by
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Wang, S., Lin, L., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl303573d · Cited by 1,307
Metadata
- Authors
- Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M.
- Venue
- Science
- Published
- 2010-08-13
- Volume
- 329
- Issue
- 5993
- Pages
- 830-834
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2103095259
- Cited by
- 798
- References
- 28
- FWCI
- 38.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.