The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates
Abstract
An antigen detection system, termed immuno-polymerase chain reaction (immuno-PCR), was developed in which a specific DNA molecule is used as the marker. A streptavidin-protein A chimera that possesses tight and specific binding affinity both for biotin and immunoglobulin G was used to attach a biotinylated DNA specifically to antigen-monoclonal antibody complexes that had been immobilized on microtiter plate wells. Then, a segment of the attached DNA was amplified by PCR. Analysis of the PCR products by agarose gel electrophoresis after staining with ethidium bromide allowed as few as 580 antigen molecules (9.6 × 10 -22 moles) to be readily and reproducibly detected. Direct comparison with enzyme-linked immunosorbent assay with the use of a chimera-alkaline phosphatase conjugate demonstrates that enhancement (approximately × 10 5 ) in detection sensitivity was obtained with the use of immuno-PCR. Given the enormous amplification capability and specificity of PCR, this immuno-PCR technology has a sensitivity greater than any existing antigen detection system and, in principle, could be applied to the detection of single antigen molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Recent Advances in the Polymerase Chain Reaction
Erlich, H. A., Gelfand, D., & Sninsky, J. J. (1991) · Science · doi:10.1126/science.2047872 · Cited by 1,077
Winter, G., & Milstein, C. (1991) · Nature · doi:10.1038/349293a0 · Cited by 945
At the Crossroads of Chemistry and Immunology: Catalytic Antibodies
Lerner, R. A., Benkovic, S. J., & Schultz, P. G. (1991) · Science · doi:10.1126/science.2024118 · Cited by 668
Shedding light on PCR contamination
SARKAR, G., & SOMMER, S. (1990) · Nature · doi:10.1038/343027a0 · Cited by 307
White, T. J., Arnheim, N., & Erlich, H. A. (1989) · Trends in Genetics · doi:10.1016/0168-9525(89)90073-5 · Cited by 226
CLARK, D. (1995) · Molecular Biology · doi:10.1016/b978-012397720-5/50024-4 · Cited by 202
DNA amplification by the polymerase chain reaction
Gibbs, R. A. (1990) · Analytical Chemistry · doi:10.1021/ac00212a004 · Cited by 174
Antibody Engineering: Advances From the Use of Escherichia coli Expression Systems
Plückthun, A. (1991) · Nature Biotechnology · doi:10.1038/nbt0691-545 · Cited by 136
A biochemical perspective of the polymerase chain reaction
Bloch, W. (1991) · Biochemistry · doi:10.1021/bi00225a001 · Cited by 132
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Biomarkers in Cancer Staging, Prognosis and Treatment Selection
Ludwig, J. A., & Weinstein, J. N. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1739 · Cited by 1,666
Protein detection using proximity-dependent DNA ligation assays
Fredriksson, S., Gullberg, M., Jarvius, J., Olsson, C., Pietras, K., Gústafsdóttir, S. M., Östman, A., & Landegren, U. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-473 · Cited by 1,504
Drivers of biodiagnostic development
Giljohann, D. A., & Mirkin, C. A. (2009) · Nature · doi:10.1038/nature08605 · Cited by 749
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Pharmaceuticals: a threat to drinking water?
Jones, O. A., Lester, J. N., & Voulvoulis, N. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.001 · Cited by 531
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
The Polymerase Chain Reaction and Plant Disease Diagnosis
Henson, J. M., & French, R. (1993) · Annual Review of Phytopathology · doi:10.1146/annurev.py.31.090193.000501 · Cited by 497
Cytokine detection by antibody-based proximity ligation
Gullberg, M., Gústafsdóttir, S. M., Schallmeiner, E., Jarvius, J., Bjarnegård, M., Betsholtz, C., Landegren, U., & Fredriksson, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400552101 · Cited by 411
Semisynthetic DNA–Protein Conjugates for Biosensing and Nanofabrication
Niemeyer, C. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904930 · Cited by 369
Twisting and stretching single DNA molecules
Strick, T., Allemand, J.-F., Croquette, V., & Bensimon, D. (2000) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(00)00018-3 · Cited by 360
Niemeyer, C. M., Sano, T., Smith, C. L., & Cantor, C. R. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.25.5530 · Cited by 335
Self-citationImmuno-PCR: high sensitivity detection of proteins by nucleic acid amplification
Niemeyer, C. M., Adler, M., & Wacker, R. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.006 · Cited by 320
Proximity ligation assays: a recent addition to the proteomics toolbox
Weibrecht, I., Leuchowius, K.-J., Clausson, C.-M., Conze, T., Jarvius, M., Howell, W. M., Kamali-Moghaddam, M., & Söderberg, O. (2010) · Expert Review of Proteomics · doi:10.1586/epr.10.10 · Cited by 309
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Engineering DNA-based functional materials
Roh, Y. H., Ruiz, R. C. H., Peng, S., Lee, J. B., & Luo, D. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15162b · Cited by 293
Gold nanoparticles-based protease assay
Guarise, C., Pasquato, L., De Filippis, V., & Scrimin, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509372103 · Cited by 284
Profiling surface proteins on individual exosomes using a proximity barcoding assay
Wu, D., Yan, J., Shen, X., Sun, Y., Thulin, M., Cai, Y., Wik, L., Shen, Q., Oelrich, J., Qian, X., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11486-1 · Cited by 276
Bailey, R. C., Kwong, G. A., Radu, C. G., Witte, O. N., & Heath, J. R. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065930i · Cited by 272
Biosensor Recognition Elements
(2008) · Current Issues in Molecular Biology · doi:10.21775/cimb.010.001 · Cited by 264
Signal Amplification by Allosteric Catalysis
Zhu, L., & Anslyn, E. V. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501476 · Cited by 151
Immuno-PCR: An ultrasensitive immunoassay for biomolecular detection
Chang, L., Li, J., & Wang, L. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.12.039 · Cited by 139
van Buggenum, J. A. G. L., Gerlach, J. P., Eising, S., Schoonen, L., van Eijl, R. A. P. M., Tanis, S. E. J., Hogeweg, M., Hubner, N. C., van Hest, J. C., Bonger, K. M., et al. (2016) · Scientific Reports · doi:10.1038/srep22675 · Cited by 93
“Structure of NHS-PEG4-tetrazine (1), and synthesis route towards NHS-s-s-PEG4-tetrazine (2), and structure of DBCO-PEG12-TCO (3).”
Metadata
- Authors
- Sano, T., Smith, C. L., & Cantor, C. R.
- Venue
- Science
- Published
- 1992-10-02
- Volume
- 258
- Issue
- 5079
- Pages
- 120-122
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2006813546
- Cited by
- 861
- References
- 21
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.