Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citationMultiple charging in electrospray ionization of poly(ethylene glycols)
Wong, S. F., Meng, C. K., & Fenn, J. B. (1988) · The Journal of Physical Chemistry · doi:10.1021/j100313a058 · Cited by 393
Self-citationCapillary zone electrophoresis-mass spectrometry using an electrospray ionization interface
Smith, R. D., Olivares, J. A., Nguyen, N. T., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00156a013 · Cited by 393
A new soft ionization technique for mass spectrometry of complex molecules
Blakley, C. R., Carmody, J. J., & Vestal, M. L. (1980) · Journal of the American Chemical Society · doi:10.1021/ja00538a050 · Cited by 275
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
Self-citationBeuhler, R. J., Flanigan, E., Greene, L. J., & Friedman, L. (1974) · Journal of the American Chemical Society · doi:10.1021/ja00819a043 · Cited by 202
Liquid chromatograph-mass spectrometer for analysis of nonvolatile samples
Blakley, C. R., Carmody, J. J., & Vestal, M. L. (1980) · Analytical Chemistry · doi:10.1021/ac50061a025 · Cited by 201
Molecular Beams of Macroions. II
Mack, L. L., Kralik, P., Rheude, A., & Ḋole, M. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1672733 · Cited by 161
Crossed-beam liquid chromatoraph—mass spectrometer combination
Blakley, C. R., McAdams, M., & Vestal, M. L. (1978) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)89972-0 · Cited by 145
Atmospheric pressure ion evaporation-mass spectrometry
Iribarne, J. V., Dziedzic, P. J., & Thomson, B. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)87009-0 · Cited by 136
Bruins, A. P., Weidolf, L. O. G., Henion, J. D., & Budde, W. L. (1987) · Analytical Chemistry · doi:10.1021/ac00149a004 · Cited by 132
Simons, D. S., Colby, B. N., & Evans, C. A. (1974) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(74)85006-0 · Cited by 128
Barber, M., Green, B. N., & Jennings, K. R. (1987) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290010505 · Cited by 127
ScienceDirect (1981) · Cited by 116
Threshold studies of secondary electron emission induced by macro-ion impact on solid surfaces
Beuhler, R. J., & Friedman, L. (1980) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(80)91031-9 · Cited by 112
Electrohydrodynamic mass spectrometry
Cook, K. D. (1986) · Mass Spectrometry Reviews · doi:10.1002/mas.1280050404 · Cited by 85
Molecular beams of macroions. III. Zein and polyvinylpyrrolidone
Clegg, G. A., & Ḋole, M. (1971) · Biopolymers · doi:10.1002/bip.360100506 · Cited by 61
Compensation for non‐normal ejection of large molecular ions in plasma‐desorption mass spectrometry
Jonsson, G., Hedin, A., Håkansson, P., Sundqvist, B., Bennich, H., & Roepstorff, P. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290030607 · Cited by 57
Combined liquid chromatograph/mass spectrometer for involatile biological samples.
Blakley, C. R., Carmody, J. C., & Vestal, M. L. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.10.1467 · Cited by 51
THEORY OF FIELD IONIZATION (FI) AND FIELD DESORPTION (FD)
Beckey, H. D. (1977) · Elsevier eBooks · doi:10.1016/b978-0-08-020612-7.50006-8 · Cited by 23
Ion Emissions from Liquids (Review)
Vestal, M. L. (1983) · Springer series in chemical physics · doi:10.1007/978-3-642-87148-1_32 · Cited by 19
Kiat, J. M., Calvarin, G., Grégoire, P., & Gamier, P. R. (1987) · Journal de physique · doi:10.1051/jphys:01987004802025300 · Cited by 14
Electrospray mass spectroscopy of macromolecule degradation in the electrospray
Teer, D., & Dole, M. (1975) · Journal of Polymer Science Polymer Physics Edition · doi:10.1002/pol.1975.180130511 · Cited by 9
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
“Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are the two techniques most commonly used to volatize and ionize the proteins or peptides for mass spectrometric analysi”
MethodSelf-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Electrospinning of Nanofibers: Reinventing the Wheel?
Li, D., & Xia, Y. (2004) · Advanced Materials · doi:10.1002/adma.200400719 · Cited by 5,521
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Muzio, M., Chinnaiyan, A. M., Kischkel, F. C., O'Rourke, K., Shevchenko, A., Ni, J., Scaffidi, C., Bretz, J. D., Zhang, M., Gentz, R., et al. (1996) · Cell · doi:10.1016/s0092-8674(00)81266-0 · Cited by 3,046
Self-citation
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.