Electrospray Ionization for Mass Spectrometry of Large Biomolecules
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Electrospray ionization has recently emerged as a powerful technique for producing intact ions in vacuo from large and complex species in solution. To an extent greater than has previously been possible with the more familiar "soft" ionization methods, this technique makes the power and elegance of mass spectrometric analysis applicable to the large and fragile polar molecules that play such vital roles in biological systems. The distinguishing features of electrospray spectra for large molecules are coherent sequences of peaks whose component ions are multiply charged, the ions of each peak differing by one charge from those of adjacent neighbors in the sequence. Spectra have been obtained for biopolymers including oligonucleotides and proteins, the latter having molecular weights up to 130,000, with as yet no evidence of an upper limit.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Electrospray ionization is a soft ionization technique that accomplishes the transfer of ions from solution to a gas phase [51].”
In the citing paper
“Although several ionization techniques are available, ESI is still predominately utilized for top-down proteomics as it is easy to interface with common LC systems [92].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [92]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Self-citationOn the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Self-citationNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Self-citation
Research works printed but not linked: 11
- Abuaf, N., Rarefied Gas Dynamics 2: 1317 (1967).
- ANDERSON, J.B., ENTROPIE 18: 33 (1976).
- Karas M. paper presented at the American Society for Mass Spectrometry (ASMS) Workshop on Ion Desorption Mechanisms Sanibel Island FL January (1989).
- Karas M. paper presented at the 11th International Mass Spectrometry Conference Bordeaux France (1988).
- MANN M THESIS YALE U (1989).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 771 (1988).
- Mann, M., Proceedings of the 36th Annual Conference on Mass Spectrometry and Allied Topics: 1207 (1988).
- SIMONS, D.S., INT J MASS SPECTROM 15: 291 (1974).
- Smith R. D. paper presented at the 5th (Montreux) Symposium on LC-MS Freidburg November (1988).
- Vestal, M. L., Mass Spectrometry in the Health and Life Sciences: 99 (1985).
- Whitehouse, C. M., Proceedings o fthe 14th Intemational Symposium on Rarefied Gas Dynamics: 857 (1985).
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
“Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) are the two techniques most commonly used to volatize and ionize the proteins or peptides for mass spectrometric analysi”
MethodSelf-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Electrospinning of Nanofibers: Reinventing the Wheel?
Li, D., & Xia, Y. (2004) · Advanced Materials · doi:10.1002/adma.200400719 · Cited by 5,521
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Muzio, M., Chinnaiyan, A. M., Kischkel, F. C., O'Rourke, K., Shevchenko, A., Ni, J., Scaffidi, C., Bretz, J. D., Zhang, M., Gentz, R., et al. (1996) · Cell · doi:10.1016/s0092-8674(00)81266-0 · Cited by 3,046
Self-citationVersatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Mass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
“…image current very low detection limit makes FT-ICR extremely attractive for biological analysis.detection is that typically Ç100 ions of a given mass-to- 25 8218 329/ 8218$$0329 09-14-98 10:53:33 msra W: MSR A key feature common to the impressive results from molecules (Fenn et al., 1989).”
BackgroundEggers, J., & Villermaux, E. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/3/036601 · Cited by 1,827
Nonlinear dynamics and breakup of free-surface flows
Eggers, J. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.865 · Cited by 1,817
Helicates as Versatile Supramolecular Complexes
Piguet, C., Bernardinelli, G., & Hopfgartner, G. (1997) · Chemical Reviews · doi:10.1021/cr960053s · Cited by 1,711
Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry
Wilm, M., Shevchenko, A., Houthaeve, T., Breit, S., Schweigerer, L., Fotsis, T., & Mann, M. (1996) · Nature · doi:10.1038/379466a0 · Cited by 1,680
Self-citationCooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
“As a result, the technique has become indispensable in the analysis and sequencing of proteins ( Fenn et al., 1989; Mehlis & Kertscher, 1997; Cao & Moini, 1998; Owens et al., 1998; Troxler et al., 1999; Alomirah, Alli, & Konishi, 2000; Le Bihan, Pinto, & Figeys, 2001; Whitelegge, Gunderson, & Faull, 2001) and oligonuc…”
MethodHenzel, W. J., Billeci, T. M., Stults, J. T., Wong, S. C., Grimley, C., & Watanabe, C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5011 · Cited by 1,305
Self-citationTaylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Reverse Transcriptase Motifs in the Catalytic Subunit of Telomerase
Lingner, J., Hughes, T. R., Shevchenko, A., Mann, M., Lundblad, V., & Cech, T. R. (1997) · Science · doi:10.1126/science.276.5312.561 · Cited by 1,269
Self-citationMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Self-citationThe abc's (and xyz's) of peptide sequencing
Steen, H., & Mann, M. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1468 · Cited by 1,150
Self-citationStudying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
“More specifically, interactions with metal ions and nucleic acids and subunit pro- electrospray ionization (ESI) (Fenn et al., 1989) has been tein structures (quaternary structure). q 1997 John Wiley & a workhorse for the mass spectrometric analysis of pep-Sons, Inc., Mass Spectrom Rev 16(1), 1–23,…”
BackgroundMolberg, Ø., Mcadam, S. N., Körner, R., Quarsten, H., Kristiansen, C., Madsen, L., Fugger, L., Scott, H., Norén, O., Roepstorff, P., et al. (1998) · Nature Medicine · doi:10.1038/nm0698-713 · Cited by 1,168
Fragmentation pathways of protonated peptides
Paizs, B., & Suhai, S. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20024 · Cited by 1,118
“Following the introduction of 'soft' ionization techniques like ESI and MALDI (Karas & Hillenkamp, 1988; Fenn et al., 1989) and the general availability of triple quadrupole and ion trap instruments, the late 1980s and early 1990s saw an unambiguous shift in MS/MS peptide analysis from the high to…”
MethodInfluentialHan, X., & Gross, R. W. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20023 · Cited by 1,106
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“F or p er so na l u se o nl y. Table 2 Approaches in mass spectrometry proteomicsa Prerequisite Advantages Drawbacks Applications Front end Analysis Top down High mass accuracy instruments High sequence coverage Precursor ion charge state limitations Single-protein characterization Ion-exchange chromatography EST LTQ-…”
MethodInfluentialAn atomic-resolution nanomechanical mass sensor
Jensen, K., Kim, K., & Zettl, A. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.200 · Cited by 1,053
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Glucosylation of Rho proteins by Clostridium difficile toxin B
Just, I., Selzer, J., Wilm, M., Eichel-Streiber, C. V., Mann, M., & Aktories, K. (1995) · Nature · doi:10.1038/375500a0 · Cited by 1,032
Self-citationInstability, unfolding and aggregation of human lysozyme variants underlying amyloid fibrillogenesis
Booth, D. R., Sunde, M., Bellotti, V., Robinson, C. V., Hutchinson, W. L., Fraser, P. E., Hawkins, P. N., Dobson, C. M., Radford, S. E., Blake, C. C. F., et al. (1997) · Nature · doi:10.1038/385787a0 · Cited by 1,048
Micro/Nano encapsulation via electrified coaxial liquid jets
Loscertales, I. G., Barrero, A., Guerrero, I., Cortijo, R., Marquez, M., & Gañán-Calvo, A. M. (2002) · Science · doi:10.1126/science.1067595 · Cited by 1,017
Water Determines the Structure and Dynamics of Proteins
Bellissent-Funel, M.-C., Hassanali, A., Havenith, M., Henchman, R., Pohl, P., Sterpone, F., van der Spoel, D., Xu, Y., & Garcia, A. E. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00664 · Cited by 945
Use of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Self-citationHan, X., & Gross, R. W. (2003) · Journal of Lipid Research · doi:10.1194/jlr.r300004-jlr200 · Cited by 914
“ESI is an ionization technique used for the mass spectrometric analysis of polar compounds that was initially developed by Fenn and colleagues ( 15 ).”
Takáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
The current emitted by highly conducting Taylor cones
De La Mora, J. F., & Loscertales, I. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094003472 · Cited by 884
Brügger, B., Erben, G., Sandhoff, R., Wieland, F. T., & Lehmann, W. D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.6.2339 · Cited by 881
Levine, R. D. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511614125 · Cited by 709
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Electrohydrodynamic spraying functioning modes: a critical review
Cloupeau, M., & Prunet-Foch, B. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90199-6 · Cited by 794
Current and droplet size in the electrospraying of liquids. Scaling laws
Gañán-Calvo, A. M., Dávila, J., & Barrero, A. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00433-8 · Cited by 780
Mass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 734
“The development of electrospray ionization (ESI) [1] and matrix-assisted laser desorption/ionization (MALDI) [2], the two soft ionization techniques capable of ionizing peptides or proteins, revolutionized protein analysis using MS.”
MethodNontarget Screening with High Resolution Mass Spectrometry in the Environment: Ready to Go?
Hollender, J., Schymanski, E. L., Singer, H. P., & Ferguson, P. L. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b02184 · Cited by 733
The NADH:ubiquinone oxidoreductase (complex I) of respiratory chains
Walker, J. E. (1992) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000425x · Cited by 781
Proteomics: the first decade and beyond
Patterson, S. D., & Aebersold, R. H. (2003) · Nature Genetics · doi:10.1038/ng1106 · Cited by 745
“ESI-MS/MS is popular because it can be combined easily with standard peptide separation tools, such as chromatography, and because it is directly compatible with the solvents that are used to solubilize peptides.”
InfluentialBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
“All those problems were overcome in 1989 when Fenn introduced electrospray ionization, a soft ionization technique, to ionize intact chemical species (proteins) by multiple charging [4].”
BackgroundMethodInfrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
“In ESI, a liquid sample flows from a microcapillary tube into the orifice of the mass spectrometer, where a potential difference between the capillary and the inlet to the mass spectrometer results in the generation of a fine mist of charged droplets (52, 72, 172).”
BackgroundAmad, M. H., Cech, N. B., Jackson, G. S., & Enke, C. G. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<784::aid-jms17>3.0.co;2-q · Cited by 191
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
“Analyte species in the fluid phase are first ionized, and bare (unsolvated) ions are produced using electrospray ionization (ESI”
MethodQuantitative, High-Resolution Proteomics for Data-Driven Systems Biology
Cox, J., & Mann, M. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061308-093216 · Cited by 685
Self-citationYeast Two-Hybrid, a Powerful Tool for Systems Biology
Brückner, A., Polge, C., Lentze, N., Auerbach, D., & Schlattner, U. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10062763 · Cited by 617
“These include Nobel prize crowned methods for ionization like electrospray ionization [30], generating ions from macromolecules in liquid medium”
Lu, X., & Elimelech, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00502a · Cited by 657
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Electrospray Wings for Molecular Elephants (Nobel Lecture)
Fenn, J. B. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200300605 · Cited by 642
Self-citationArentz-Hansen, H., Körner, R., Molberg, Ø., Quarsten, H., Vader, W., Kooy, Y. M. C., Lundin, K. E. A., Koning, F., Roepstorff, P., Sollid, L. M., et al. (2000) · The Journal of Experimental Medicine · doi:10.1084/jem.191.4.603 · Cited by 654
“spectrometry (MS/MS) experiments (24), a nanoelectrospray ion”
Sinz, A. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20082 · Cited by 648
“The soft-ionization techniques MALDI (Karas & Hillenkamp, 1988) and ESI (electrospray ionization) (Fenn et al., 1989) are the predominately employed methods to analyze crosslinking mixtures of proteins.”
MethodGood Practices in Free-Energy Calculations
Pohorille, A., Jarzynski, C., & Chipot, C. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp102971x · Cited by 633
Interferences and contaminants encountered in modern mass spectrometry
Keller, B. O., Sui, J., Young, A. B., & Whittal, R. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.043 · Cited by 623
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
“The introduction of electrospray ionization (ESI) by Fenn and colleagues (21) provides ready access to charged microdroplets under ambient conditions.”
BackgroundNANOFIBROUS MATERIALS AND THEIR APPLICATIONS
Burger, C., Hsiao, B. S., & Chu, B. (2006) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.36.011205.123537 · Cited by 622
Meot-Ner (Mautner), M. (2005) · Chemical Reviews · doi:10.1021/cr9411785 · Cited by 618
In Situ, Time-Resolved, and Mechanistic Studies of Metal–Organic Framework Nucleation and Growth
Van Vleet, M. J., Weng, T., Li, X., & Schmidt, J. R. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00582 · Cited by 610
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
The Fluid Dynamics of Taylor Cones
Fernández de la Mora, J. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110159 · Cited by 594
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Thus, an unfolded/ less structured protein in its most expanded form (i.e., in acidified organic solvent) will pick up more charges during ESI than a folded/more structured protein (i.e., electrosprayed from aqueous solution).”
BackgroundMethodInfluentialInvestigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
“, 1991) and electrospray ionization (ESI) (Wong, Meng, & Fenn, 1988; Fenn et al., 1989; Chowdhury, Katta, & Chait, 1990a,b; Meng & Fenn, 1990; Light-Wahl et al., 1993; Mann & Wilm, 1995) in the late 1980s.”
Method2,5-Dihydroxybenzoic acid: a new matrix for laser desorption—ionization mass spectrometry
Strupat, K., Karas, M., & Hillenkamp, F. (1991) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(91)85050-v · Cited by 580
Mass appeal: metabolite identification in mass spectrometry-focused untargeted metabolomics
Dunn, W. B., Erban, A., Weber, R. J. M., Creek, D. J., Brown, M., Breitling, R., Hankemeier, T., Goodacre, R., Neumann, S., Kopka, J., et al. (2013) · Metabolomics · doi:10.1007/s11306-012-0434-4 · Cited by 555
“These platforms typically utilize ESI sources (Fenn et al. 1989), though other ion sources (or combinations of ionization mechanisms) are sometimes used, including APCI (An et al. 2010).”
Schug, K. A., & Lindner, W. (2005) · Chemical Reviews · doi:10.1021/cr040603j · Cited by 579
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
“The application of electrospray ionization (ESI) turns solution-phase intact proteoforms into positively charged molecular ions that are further desolvated with the assistance of heat and gas flow and ultimately liberated as gas-phase protein cations (8).”
BackgroundMethodInfluentialSmith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
3D printed polyamide membranes for desalination
Chowdhury, M. R., Steffes, J., Huey, B. D., & McCutcheon, J. R. (2018) · Science · doi:10.1126/science.aar2122 · Cited by 570
Tandem Mass Spectrometry of Small, Multiply Charged Oligonucleotides
Mcluckey, S. A., Van Berkel, G. J., & Glish, G. L. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85019-g · Cited by 551
Regulation of Lipid A Modifications by Salmonella typhimurium Virulence Genes phoP-phoQ
Guo, L., Lim, K. B., Gunn, J. S., Bainbridge, B., Darveau, R. P., Hackett, M., & Miller, S. I. (1997) · Science · doi:10.1126/science.276.5310.250 · Cited by 559
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
“Atmospheric pressure ionization (API) (Bruins, 1991; Carroll et al., 1974; Horning et al., 1973) sources such as ESI (Dole, Mack, & Hines, 1968; Fenn et al., 1989; Whitehouse et al., 1985; Yamashita & Fenn, 1984a,b) and atmospheric pressure chemical ionization (APCI) (Carroll et al., 1975; Horning…”
BackgroundDemarque, D. P., Crotti, A. E. M., Vessecchi, R., Lopes, J. L. C., & Lopes, N. P. (2016) · Natural Product Reports · doi:10.1039/c5np00073d · Cited by 513
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Self-citationLuo, Z., Castleman, A. W., & Khanna, S. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00230 · Cited by 515
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Semiconductor-Based Composite Materials: Preparation, Properties, and Performance
Rajeshwar, K., de Tacconi, N. R., & Chenthamarakshan, C. R. (2001) · Chemistry of Materials · doi:10.1021/cm010254z · Cited by 510
Zhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Ambient Ionization Mass Spectrometry: Recent Developments and Applications
Feider, C. L., Krieger, A., DeHoog, R. J., & Eberlin, L. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00807 · Cited by 496
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Carpentier, S. C., Witters, E., Laukens, K., Deckers, P., Swennen, R., & Panis, B. (2005) · PROTEOMICS · doi:10.1002/pmic.200401222 · Cited by 504
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
Bovine Complex I Is a Complex of 45 Different Subunits
Carroll, J., Fearnley, I. M., Skehel, J. M., Shannon, R. J., Hirst, J., & Walker, J. E. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m607135200 · Cited by 487
Cancer and the tumor microenvironment: a review of an essential relationship
Mbeunkui, F., & Johann, D. J. (2009) · Cancer Chemotherapy and Pharmacology · doi:10.1007/s00280-008-0881-9 · Cited by 487
“Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI), are the common techniques used to volatilize and ionize proteins or peptides for mass spectrometry analysis [30].”
MethodSmall‐scale free surface flows with breakup: Drop formation and emerging applications
Basaran, O. A. (2002) · AIChE Journal · doi:10.1002/aic.690480902 · Cited by 478
Clathrate nanostructures for mass spectrometry
Northen, T. R., Yanes, O., Northen, M. T., Marrinucci, D., Uritboonthai, W., Apon, J., Golledge, S. L., Nordström, A., & Siuzdak, G. (2007) · Nature · doi:10.1038/nature06195 · Cited by 480
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Daniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475
Selective Activation of Alkanes by Gas-Phase Metal Ions
Roithová, J., & Schröder, D. (2010) · Chemical Reviews · doi:10.1021/cr900183p · Cited by 477
Metadata
- Authors
- Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M.
- Affiliations
- Yale University (US)
- Venue
- Science
- Published
- 1989-10-06
- Volume
- 246
- Issue
- 4926
- Pages
- 64-71
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2073292063
- Cited by
- 7,634
- References
- 32
- Citations by year
- 2026: 126 · 2025: 157 · 2024: 177 · 2023: 194 · 2022: 164 · 2021: 213 · 2020: 220 · 2019: 240 · 2018: 227 · 2017: 255 · 2016: 251 · 2015: 316 · 2014: 327 · 2013: 340 · 2012: 395
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- electrospray ionization, large biomolecules, multiply charged ions, biopolymers, oligonucleotides, proteins, soft ionization
- MeSH terms
- Ions, Molecular Weight, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.