Surface Stress in the Self-Assembly of Alkanethiols on Gold
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Surface stress changes and kinetics were measured in situ during the self-assembly of alkanethiols on gold by means of a micromechanical sensor. Self-assembly caused compressive surface stress that closely followed Langmuir-type adsorption kinetics up to monolayer coverage. The surface stress at monolayer coverage increased linearly with the length of the alkyl chain of the molecule. These observations were interpreted in terms of differences in surface potential. This highly sensitive sensor technique has a broad range of applicability to specific chemical and biological interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Self-citationThe tension of metallic films deposited by electrolysis
Stoney, G. G. (1909) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1909.0021 · Cited by 4,872
Molecular Self-Assembly and Nanochemistry: a Chemical Strategy for the Synthesis of Nanostructures
Whitesides, G. M., Mathias, J. P., & Seto, C. T. (1991) · Science · doi:10.1126/science.1962191 · Cited by 3,632
Adsorption of bifunctional organic disulfides on gold surfaces
Nuzzo, R. G., & Allara, D. L. (1983) · Journal of the American Chemical Society · doi:10.1021/ja00351a063 · Cited by 2,316
Nuzzo, R. G., Dubois, L. H., & Allara, D. L. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00158a012 · Cited by 1,569
Patterning Self-Assembled Monolayers: Applications in Materials Science
Kumar, A., Biebuyck, H. A., & Whitesides, G. M. (1994) · Langmuir · doi:10.1021/la00017a030 · Cited by 1,114
Observation of a chemical reaction using a micromechanical sensor
Gimzewski, J. K., Gerber, C., Meyer, E., & Schlittler, R. R. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(93)e1419-h · Cited by 521
Self-citationIn Situ Kinetics of Self-Assembly by Surface Plasmon Resonance Spectroscopy
Peterlinz, K. A., & Georgiadis, R. (1996) · Langmuir · doi:10.1021/la9508452 · Cited by 461
Thermal and ambient-induced deflections of scanning force microscope cantilevers
Thundat, T., Warmack, R. J., Chen, G. Y., & Allison, D. P. (1994) · Applied Physics Letters · doi:10.1063/1.111407 · Cited by 419
Photothermal spectroscopy with femtojoule sensitivity using a micromechanical device
Barnes, J. R., Stephenson, R. J., Welland, M. E., Gerber, C., & Gimzewski, J. K. (1994) · Nature · doi:10.1038/372079a0 · Cited by 327
Self-citation
Cited by
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Self-citationSelf-assembled monolayers of thiols and dithiols on gold: new challenges for a well-known system
Vericat, C., Vela, M. E., Benitez, G., Carro, P., & Salvarezza, R. C. (2010) · Chemical Society Reviews · doi:10.1039/b907301a · Cited by 1,472
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Interfaces and stresses in thin films
Spaepen, F. (2000) · Acta Materialia · doi:10.1016/s1359-6454(99)00286-4 · Cited by 531
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Ziegler, C. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2694-y · Cited by 414
Surface-Stress Induced Macroscopic Bending of Nanoporous Gold Cantilevers
Kramer, D., Viswanath, R. N., & Weissmüller, J. (2004) · Nano Letters · doi:10.1021/nl049927d · Cited by 409
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Surface stress effect in mechanics of nanostructured materials
Wang, J., Huang, Z., Duan, H., Yu, S., Feng, X., Wang, G., Zhang, W., & Wang, T. (2011) · Acta Mechanica Solida Sinica · doi:10.1016/s0894-9166(11)60009-8 · Cited by 349
Surface grafted polymer brushes as ideal building blocks for “smart” surfaces
Zhou, F., & Huck, W. T. S. (2006) · Phys. Chem. Chem. Phys. · doi:10.1039/b606415a · Cited by 283
Adsorption-induced deformation of nanoporous materials—A review
Gor, G. Y., Huber, P., & Bernstein, N. (2017) · Applied Physics Reviews · doi:10.1063/1.4975001 · Cited by 273
Wee, K. W., Kang, G. Y., Park, J., Kang, J. Y., Yoon, D. S., Park, J. H., & Kim, T. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.023 · Cited by 272
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Microcantilever resonance-based DNA detection with nanoparticle probes
Su, M., Li, S., & Dravid, V. P. (2003) · Applied Physics Letters · doi:10.1063/1.1576915 · Cited by 253
Bimaterial Microcantilevers as a Hybrid Sensing Platform
Singamaneni, S., LeMieux, M. C., Lang, H. P., Gerber, C., Lam, Y., Zauscher, S., Datskos, P. G., Lavrik, N. V., Jiang, H., Naik, R. R., et al. (2008) · Advanced Materials · doi:10.1002/adma.200701667 · Cited by 185
Self-citation
Metadata
- Authors
- Berger, R., Delamarche, E., Lang, H. P., Gerber, C., Gimzewski, J. K., Meyer, E., & Güntherodt, H.-J.
- Venue
- Science
- Published
- 1997-06-27
- Volume
- 276
- Issue
- 5321
- Pages
- 2021-2024
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2091723149
- Cited by
- 544
- References
- 14
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.