The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
How Strong Is a Covalent Bond?
Abstract
The rupture force of single covalent bonds under an external load was measured with an atomic force microscope (AFM). Single polysaccharide molecules were covalently anchored between a surface and an AFM tip and then stretched until they became detached. By using different surface chemistries for the attachment, it was found that the silicon-carbon bond ruptured at 2.0 ± 0.3 nanonewtons, whereas the sulfur-gold anchor ruptured at 1.4 ± 0.3 nanonewtons at force-loading rates of 10 nanonewtons per second. Bond rupture probability calculations that were based on density functional theory corroborate the measured values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density-functional thermochemistry. III. The role of exact exchange
Becke, A. D. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464913 · Cited by 103,767
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Smith, S. B., Cui, Y., & Bustamante, C. (1996) · Science · doi:10.1126/science.271.5250.795 · Cited by 2,770
Dynamic strength of molecular adhesion bonds
Evans, E., & Ritchie, K. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78802-7 · Cited by 2,549
Energy landscapes of receptor–ligand bonds explored with dynamic force spectroscopy
Merkel, R., Nassoy, P., Leung, A., Ritchie, K., & Evans, E. (1999) · Nature · doi:10.1038/16219 · Cited by 1,721
Hinterdorfer, P., Baumgartner, W., Gruber, H. J., Schilcher, K., & Schindler, H. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.8.3477 · Cited by 1,170
Single Molecule Force Spectroscopy on Polysaccharides by Atomic Force Microscopy
Rief, M., Oesterhelt, F., Heymann, B., & Gaub, H. E. (1997) · Science · doi:10.1126/science.275.5304.1295 · Cited by 1,124
Self-citationThe molecular elasticity of the extracellular matrix protein tenascin
Oberhauser, A. F., Marszalek, P. E., Erickson, H. P., & Fernandez, J. M. (1998) · Nature · doi:10.1038/30270 · Cited by 841
Löfås, S., & Johnsson, B. (1990) · J. Chem. Soc., Chem. Commun. · doi:10.1039/c39900001526 · Cited by 766
Decreased Resistance to Bacterial Infection and Granulocyte Defects in IAP-Deficient Mice
Lindberg, F. P., Bullard, D. C., Caver, T. E., Gresham, H. D., Beaudet, A. L., & Brown, E. J. (1996) · Science · doi:10.1126/science.274.5288.795 · Cited by 607
Polysaccharide elasticity governed by chair–boat transitions of the glucopyranose ring
Marszalek, P. E., Oberhauser, A. F., Pang, Y.-P., & Fernandez, J. M. (1998) · Nature · doi:10.1038/25322 · Cited by 451
Specific antigen/antibody interactions measured by force microscopy
Dammer, U., Hegner, M., Anselmetti, D., Wagner, P., Dreier, M., Huber, W., & Güntherodt, H. J. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79814-4 · Cited by 442
Direct Observation of Enzyme Activity with the Atomic Force Microscope
Radmacher, M., Fritz, M., Hansma, H. G., & Hansma, P. K. (1994) · Science · doi:10.1126/science.8079171 · Cited by 405
Flow‐induced chain fracture of isolated linear macromolecules in solution
Odell, J. A., & Keller, A. (1986) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.1986.090240901 · Cited by 256
Direct mechanical measurement of interatomic potentials
Jarvis, S., Yamada, H., Yamamoto, S., Tokumoto, H., & Pethica, J. B. (1996) · Nature · doi:10.1038/384247a0 · Cited by 137
Detachment of a single polyelectrolyte chain adsorbed on a charged surface
Châtellier, X., Senden, T. J., Joanny, J., & di Meglio, J.-M. (1998) · Europhysics Letters (EPL) · doi:10.1209/epl/i1998-00147-6 · Cited by 110
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Single-molecule mechanics of mussel adhesion
Lee, H., Scherer, N. F., & Messersmith, P. B. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605552103 · Cited by 2,112
Mechanically-Induced Chemical Changes in Polymeric Materials
Caruso, M. M., Davis, D. A., Shen, Q., Odom, S. A., Sottos, N. R., White, S. R., & Moore, J. S. (2009) · Chemical Reviews · doi:10.1021/cr9001353 · Cited by 1,372
Probing the Relation Between Force—Lifetime—and Chemistry in Single Molecular Bonds
Evans, E. (2001) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.30.1.105 · Cited by 1,325
Metadata
- Authors
- Grandbois, M., Beyer, M., Rief, M., Clausen-Schaumann, H., & Gaub, H. E.
- Venue
- Science
- Published
- 1999-03-12
- Volume
- 283
- Issue
- 5408
- Pages
- 1727-1730
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2047060525
- Cited by
- 1,095
- References
- 16
- FWCI
- 22.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.