The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Human-in-the-loop optimization of exoskeleton assistance during walking
Abstract
Optimum human input: Exoskeletons can be used to augment human abilities—for example, to lift very heavy loads or to provide greater endurance. For each user, though, a device will need to be adjusted for optimum effect, which can be time-consuming. Zhang et al. show that the human can be included in the optimization process, with real-time adaptation of an ankle exoskeleton (see the Perspective by Malcolm et al. ). By using indirect calorimetry to measure metabolic rates, the authors were able to adjust the torque provided by the device while users were walking, running, and carrying a load. Science , this issue p. 1280 ; see also p. 1230
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Completely Derandomized Self-Adaptation in Evolution Strategies
Hansen, N., & Ostermeier, A. (2001) · Evolutionary Computation · doi:10.1162/106365601750190398 · Cited by 4,397
Efficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873
Self-citationThe CMA Evolution Strategy: A Comparing Review
Hansen, N. (2007) · Studies in Fuzziness and Soft Computing · doi:10.1007/3-540-32494-1_4 · Cited by 1,797
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Self-citationEvaluating the CMA Evolution Strategy on Multimodal Test Functions
Hansen, N., & Kern, S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-30217-9_29 · Cited by 758
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Optimization and gaits in the locomotion of vertebrates
Alexander, R. M. (1989) · Physiological Reviews · doi:10.1152/physrev.1989.69.4.1199 · Cited by 613
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Computer optimization of a minimal biped model discovers walking and running
Srinivasan, M., & Ruina, A. (2006) · Nature · doi:10.1038/nature04113 · Cited by 580
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Biorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
Dynamic arm swinging in human walking
Collins, S. H., Adamczyk, P. G., & Kuo, A. D. (2009) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2009.0664 · Cited by 406
Self-citationHumans can continuously optimize energetic cost during walking
Selinger, J. C., O’Connor, S. M., Wong, J. D., & Donelan, J. M. (2015) · Current Biology · doi:10.1016/j.cub.2015.08.016 · Cited by 395
Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Oxygen Uptake Kinetics in Sport, Exercise and Medicine
Jones, A. M., & Poole, D. C. (2013) · doi:10.4324/9780203613771 · Cited by 342
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318
The CMA Evolution Strategy: A Comparing Review
Nikolaus Hansen, C. (2006) · Springer eBooks · doi:10.1007/11007937_4 · Cited by 311
Altered Running Economy Directly Translates to Altered Distance-Running Performance
HOOGKAMER, W., KIPP, S., SPIERING, B. A., & KRAM, R. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001012 · Cited by 230
Recycling Energy to Restore Impaired Ankle Function during Human Walking
Collins, S. H., & Kuo, A. D. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009307 · Cited by 219
Self-citationPowered Lower Limb Orthoses for Gait Rehabilitation
Ferris, D., Sawicki, G., & Domingo, A. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/6gl4-um7x-519h-9jyd · Cited by 214
Jackson, R. W., & Collins, S. H. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01133.2014 · Cited by 205
Self-citationFully autonomous hip exoskeleton saves metabolic cost of walking
Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487663 · Cited by 177
Neurocognitive barriers to the embodiment of technology
Makin, T. R., de Vignemont, F., & Faisal, A. A. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0014 · Cited by 165
Simulating Ideal Assistive Devices to Reduce the Metabolic Cost of Running
Uchida, T. K., Seth, A., Pouya, S., Dembia, C. L., Hicks, J. L., & Delp, S. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163417 · Cited by 164
Koller, J. R., Jacobs, D. A., Ferris, D. P., & Remy, C. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0086-5 · Cited by 162
A Universal Ankle–Foot Prosthesis Emulator for Human Locomotion Experiments
Caputo, J. M., & Collins, S. H. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4026225 · Cited by 159
Self-citationAutonomous exoskeleton reduces metabolic cost of human walking
Mooney, L. M., Rouse, E. J., & Herr, H. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-151 · Cited by 155
Tools for understanding and optimizing robotic gait training
Reinkensmeyer, D. J., Aoyagi, D., Emken, J. L., Galvez, J. A., Ichinose, W. E., Kerdanyan, G., Maneekobkunwong, S., Minakata, K., Nessler, J. A., Weber, R., et al. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.04.0073 · Cited by 150
Design of two lightweight, high-bandwidth torque-controlled ankle exoskeletons
Witte, K. A., Zhang, J., Jackson, R. W., & Collins, S. H. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139347 · Cited by 149
Self-citationEstimating instantaneous energetic cost during non-steady-state gait
Selinger, J. C., & Donelan, J. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00445.2014 · Cited by 141
Exotendons for assistance of human locomotion
van den Bogert, A. J. (2003) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-2-17 · Cited by 139
"Body-In-The-Loop": Optimizing Device Parameters Using Measures of Instantaneous Energetic Cost
Felt, W., Selinger, J. C., Donelan, J. M., & Remy, C. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0135342 · Cited by 137
Toward Balance Recovery With Leg Prostheses Using Neuromuscular Model Control
Thatte, N., & Geyer, H. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2472533 · Cited by 134
Hoeffding and Bernstein races for selecting policies in evolutionary direct policy search
Heidrich-Meisner, V., & Igel, C. (2009) · International Conference on Machine Learning · doi:10.1145/1553374.1553426 · Cited by 126
Experimental comparison of torque control methods on an ankle exoskeleton during human walking
Zhang, J., Cheah, C. C., & Collins, S. H. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139980 · Cited by 125
Self-citationQuesada, R. E., Caputo, J. M., & Collins, S. H. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.09.015 · Cited by 124
Self-citation'Body-in-the-Loop' Optimization of Assistive Robotic Devices: A Validation Study
Koller, J. R., Gates, D. H., Ferris, D. P., & Remy, C. D. (2016) · Robotics: Science and Systems · doi:10.15607/rss.2016.xii.007 · Cited by 115
Elastic ankle exoskeletons reduce soleus muscle force but not work in human hopping
Farris, D. J., Robertson, B., & Sawicki, G. S. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00253.2013 · Cited by 101
Jackson, R. W., Dembia, C. L., Delp, S. L., & Collins, S. H. (2017) · Journal of Experimental Biology · doi:10.1242/jeb.150011 · Cited by 90
Self-citationXPED2: A Passive Exoskeleton with Artificial Tendons
van Dijk, W., & van der Kooij, H. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360309 · Cited by 89
Learning assistive strategies for exoskeleton robots from user-robot physical interaction
Hamaya, M., Matsubara, T., Noda, T., Teramae, T., & Morimoto, J. (2017) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.04.007 · Cited by 80
Enhancing performance during inclined loaded walking with a powered ankle–foot exoskeleton
Galle, S., Malcolm, P., Derave, W., & Clercq, D. D. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2955-1 · Cited by 49
In pursuit of the perfect power suit
Cornwall, W. (2015) · Science · doi:10.1126/science.350.6258.270 · Cited by 43
Cited by
A survey of human-in-the-loop for machine learning
Wu, X., Xiao, L., Sun, Y., Zhang, J., Ma, T., & He, L. (2022) · Future Generation Computer Systems · doi:10.1016/j.future.2022.05.014 · Cited by 800
Self-citationHuman-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
Reducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
Haptics: The Present and Future of Artificial Touch Sensation
Culbertson, H., Schorr, S. B., & Okamura, A. M. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105043 · Cited by 431
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Metadata
- Authors
- Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H.
- Venue
- Science
- Published
- 2017-06-23
- Volume
- 356
- Issue
- 6344
- Pages
- 1280-1284
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2700163520
- Cited by
- 1,011
- References
- 49
- FWCI
- 28.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.