The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Ghost cytometry
Abstract
Seeing ghosts: In fluorescence-activated cell sorting, characteristic target features are labeled with a specific fluorophore, and cells displaying different fluorophores are sorted. Ota et al. describe a technique called ghost cytometry that allows cell sorting based on the morphology of the cytoplasm, labeled with a single-color fluorophore. The motion of cells relative to a patterned optical structure provides spatial information that is compressed into temporal signals, which are sequentially measured by a single-pixel detector. Images can be reconstructed from this spatial and temporal information, but this is computationally costly. Instead, using machine learning, cells are classified directly from the compressed signals, without reconstructing an image. The method was able to separate morphologically similar cell types in an ultrahigh-speed fluorescence imaging–activated cell sorter. Science , this issue p. 1246
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Single-pixel imaging via compressive sampling
Duarte, M. F., Davenport, M. A., Takhar, D., Laska, J. N., Sun, T., Kelly, K. F., & Baraniuk, R. G. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914730 · Cited by 3,575
A New TwIST: Two-Step Iterative Shrinkage/Thresholding Algorithms for Image Restoration
Bioucas-Dias, J. M., & Figueiredo, M. A. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909319 · Cited by 2,064
Shapiro, J. H. (2008) · Physical Review A · doi:10.1103/physreva.78.061802 · Cited by 1,531
Whole-Brain Imaging with Single-Cell Resolution Using Chemical Cocktails and Computational Analysis
Susaki, E. A., Tainaka, K., Perrin, D., Kishino, F., Tawara, T., Watanabe, T. M., Yokoyama, C., Onoe, H., Eguchi, M., Yamaguchi, S., et al. (2014) · Cell · doi:10.1016/j.cell.2014.03.042 · Cited by 1,325
Self-citationKatz, O., Bromberg, Y., & Silberberg, Y. (2009) · Applied Physics Letters · doi:10.1063/1.3238296 · Cited by 1,018
Ghost Imaging with Thermal Light: Comparing Entanglement and ClassicalCorrelation
Gatti, A., Brambilla, E., Bache, M., & Lugiato, L. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.093602 · Cited by 930
3D Computational Imaging with Single-Pixel Detectors
Sun, B., Edgar, M., Bowman, R. W., Vittert, L., Welsh, S. S., BOWMAN, A. W., & Padgett, M. J. (2013) · Science · doi:10.1126/science.1234454 · Cited by 914
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena
Goda, K., Tsia, K. K., & Jalali, B. (2009) · Nature · doi:10.1038/nature07980 · Cited by 763
Single-shot compressed ultrafast photography at one hundred billion frames per second
Gao, L., Liang, J., Li, C., & Wang, L. V. (2014) · Nature · doi:10.1038/nature14005 · Cited by 629
Asymmetric cell division: recent developments and their implications for tumour biology
Knoblich, J. A. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3010 · Cited by 578
Compressive Sensing by Random Convolution
Romberg, J. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/08072975x · Cited by 458
Compressive fluorescence microscopy for biological and hyperspectral imaging
Studer, V., Bobin, J., Chahid, M., Mousavi, H. S., Candes, E., & Dahan, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119511109 · Cited by 411
B Cell Receptor Signal Transduction in the GC Is Short-Circuited by High Phosphatase Activity
Khalil, A. M., Cambier, J. C., & Shlomchik, M. J. (2012) · Science · doi:10.1126/science.1213368 · Cited by 281
Review: imaging technologies for flow cytometry
Han, Y., Gu, Y., Zhang, A. C., & Lo, Y. (2016) · Lab on a Chip · doi:10.1039/c6lc01063f · Cited by 272
Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy
Diebold, E. D., Buckley, B. W., Gossett, D. R., & Jalali, B. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.245 · Cited by 175
Asymmetric Segregation of Polarized Antigen on B Cell Division Shapes Presentation Capacity
Thaunat, O., Granja, A. G., Barral, P., Filby, A. J., Montaner, B., Collinson, L., Martínez, N., Harwood, N. E., Bruckbauer, A., & Batista, F. D. (2012) · Science · doi:10.1126/science.1214100 · Cited by 143
Sparse Recovery of Nonnegative Signals With Minimal Expansion
Khajehnejad, M. A., Dimakis, A. G., Xu, W., & Hassibi, B. (2010) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2010.2082536 · Cited by 101
Takao, M., & Takeda, K. (2011) · Cytometry Part A · doi:10.1002/cyto.a.21014 · Cited by 90
Dent, B., Ogle, L. F., O'Donnell, R. L., Hayes, N., Mallick, U. K., Curtin, N. J., Boddy, A. V., Plummer, E. R., Edmondson, R. J., Reeves, H. L., et al. (2015) · International Journal of Cancer · doi:10.1002/ijc.29680 · Cited by 49
Imaging flow cytometry for the study of erythroid cell biology and pathology
Samsel, L., & McCoy, J. P. (2015) · Journal of Immunological Methods · doi:10.1016/j.jim.2015.03.019 · Cited by 42
Guo, B., Lei, C., Ito, T., Jiang, Y., Ozeki, Y., & Goda, K. (2016) · PLoS ONE · doi:10.1371/journal.pone.0166214 · Cited by 28
Sun, W., Jia, C., Huang, T., Sheng, W., Li, G., Zhang, H., Jing, F., Jin, Q., Zhao, J., Li, G., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075865 · Cited by 19
Cited by
High-performance medicine: the convergence of human and artificial intelligence
Topol, E. J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0300-7 · Cited by 10,450
Liquid biopsy enters the clinic — implementation issues and future challenges
Ignatiadis, M., Sledge, G. W., & Jeffrey, S. S. (2021) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-00457-x · Cited by 1,191
Principles and prospects for single-pixel imaging
Edgar, M. P., Gibson, G. M., & Padgett, M. J. (2019) · Nature Photonics · doi:10.1038/s41566-018-0300-7 · Cited by 1,029
Intelligent Image-Activated Cell Sorting
Nitta, N., Sugimura, T., Isozaki, A., Mikami, H., Hiraki, K., Sakuma, S., Iino, T., Arai, F., Endo, T., Fujiwaki, Y., et al. (2018) · Cell · doi:10.1016/j.cell.2018.08.028 · Cited by 538
Intelligent nanophotonics: merging photonics and artificial intelligence at the nanoscale
Yao, K., Unni, R., & Zheng, Y. (2019) · Nanophotonics · doi:10.1515/nanoph-2018-0183 · Cited by 302
Metadata
- Authors
- Ota, S., Horisaki, R., Kawamura, Y., Ugawa, M., Sato, I., Hashimoto, K., Kamesawa, R., Setoyama, K., Yamaguchi, S., Fujiu, K., Waki, K., & Noji, H.
- Venue
- Science
- Published
- 2018-06-15
- Volume
- 360
- Issue
- 6394
- Pages
- 1246-1251
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4213078347
- Cited by
- 257
- References
- 27
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.