Micro-NMR for Rapid Molecular Analysis of Human Tumor Samples
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A portable micro-NMR device enables rapid molecular diagnosis from scarce cancer cells in fine-needle aspirates from human tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basics of epithelial-mesenchymal transition
Kalluri, R., & Weinberg, R. A. (2009) · Journal of Clinical Investigation · doi:10.1172/jci39104 · Cited by 10,196 · cited 1×
“Finally, we investigated vimentin as a cancer marker because this intermediate filament protein has been associated with the epithelial-mesenchymal transition (30), cancer metastases (31), and resistance to chemotherapy (32).”
BackgroundCancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Identification of splenic reservoir monocytes and their deployment to inflammatory sites
Swirski, F. K., Nahrendorf, M., Etzrodt, M., Wildgruber, M., Cortez-Retamozo, V., Panizzi, P., Figueiredo, J.-L., Kohler, R. H., Chudnovskiy, A., Waterman, P., et al. (2009) · Science · doi:10.1126/science.1175202 · Cited by 2,221
Self-citationVogel, C. L., Cobleigh, M. A., Tripathy, D., Gutheil, J. C., Harris, L. N., Fehrenbacher, L., Slamon, D. J., Murphy, M., Novotny, W. F., Burchmore, M., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.20.3.719 · Cited by 1,860
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Erez, N., Truitt, M., Olson, P., & Hanahan, D. (2010) · Cancer Cell · doi:10.1016/j.ccr.2009.12.041 · Cited by 1,515
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621
Self-citationRoth, T. J., Sheinin, Y., Lohse, C. M., Kuntz, S. M., Frigola, X., Inman, B. A., Krambeck, A. E., Mckenney, M. E., Karnes, R. J., Blute, M. L., et al. (2007) · Cancer Research · doi:10.1158/0008-5472.can-07-1068 · Cited by 267
Monocyte Subset Dynamics in Human Atherosclerosis Can Be Profiled with Magnetic Nano-Sensors
Wildgruber, M., Lee, H., Chudnovskiy, A., Yoon, T.-J., Etzrodt, M., Pittet, M. J., Nahrendorf, M., Croce, K., Libby, P., Weissleder, R., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005663 · Cited by 54
Self-citation
Cited by
Inverse electron demand Diels–Alder reactions in chemical biology
Oliveira, B. L., Guo, Z., & Bernardes, G. J. L. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00184c · Cited by 1,139
Protein typing of circulating microvesicles allows real-time monitoring of glioblastoma therapy
Shao, H., Chung, J., Balaj, L., Charest, A., Bigner, D. D., Carter, B. S., Hochberg, F. H., Breakefield, X. O., Weissleder, R., & Lee, H. (2012) · Nature Medicine · doi:10.1038/nm.2994 · Cited by 759
Self-citationMicrofluidic technologies for accelerating the clinical translation of nanoparticles
Valencia, P. M., Farokhzad, O. C., Karnik, R., & Langer, R. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.168 · Cited by 698
Tassa, C., Shaw, S. Y., & Weissleder, R. (2011) · Accounts of Chemical Research · doi:10.1021/ar200084x · Cited by 653
Self-citationMagnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Biomedical Applications of Tetrazine Cycloadditions
Devaraj, N. K., & Weissleder, R. (2011) · Accounts of Chemical Research · doi:10.1021/ar200037t · Cited by 516
Self-citationConde, J., Dias, J. T., Grazú, V., Moros, M., Baptista, P. V., & de la Fuente, J. M. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00048 · Cited by 425
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
High-sensitivity nanosensors for biomarker detection
Swierczewska, M., Liu, G., Lee, S., & Chen, X. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15238f · Cited by 361
Recent Developments in Magnetic Diagnostic Systems
Lee, H., Shin, T.-H., Cheon, J., & Weissleder, R. (2015) · Chemical Reviews · doi:10.1021/cr500698d · Cited by 292
Self-citationMagnetic nanoparticles: a novel platform for cancer theranostics
Singh, A., & Sahoo, S. K. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.10.005 · Cited by 289
Multiparametric plasma EV profiling facilitates diagnosis of pancreatic malignancy
Yang, K. S., Im, H., Hong, S., Pergolini, I., del Castillo, A. F., Wang, R., Clardy, S., Huang, C.-H., Pille, C., Ferrone, S., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aal3226 · Cited by 277
Self-citationT2 Magnetic Resonance Enables Nanoparticle-Mediated Rapid Detection of Candidemia in Whole Blood
Neely, L. A., Audeh, M., Phung, N. A., Min, M., Suchocki, A., Plourde, D., Blanco, M., Demas, V., Skewis, L. R., Anagnostou, T., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005377 · Cited by 272
Micro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Diagnostic and Prognostic Potential of Extracellular Vesicles in Peripheral Blood
Revenfeld, A. L. S., Bæk, R., Nielsen, M. H., Stensballe, A., Varming, K., & Jørgensen, M. (2014) · Clinical Therapeutics · doi:10.1016/j.clinthera.2014.05.008 · Cited by 258
Bioorthogonal Reaction Pairs Enable Simultaneous, Selective, Multi‐Target Imaging
Karver, M. R., Weissleder, R., & Hilderbrand, S. A. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201104389 · Cited by 220
Self-citationLagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
Mass-encoded synthetic biomarkers for multiplexed urinary monitoring of disease
Kwong, G. A., von Maltzahn, G., Murugappan, G., Abudayyeh, O., Mo, S., Papayannopoulos, I. A., Sverdlov, D. Y., Liu, S. B., Warren, A. D., Popov, Y., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2464 · Cited by 213
Molecular imaging for personalized cancer care
Kircher, M. F., Hricak, H., & Larson, S. M. (2012) · Molecular Oncology · doi:10.1016/j.molonc.2012.02.005 · Cited by 193
Magnetic barcode assay for genetic detection of pathogens
Liong, M., Hoang, A. N., Chung, J., Gural, N., Ford, C. B., Min, C., Shah, R. R., Ahmad, R., Fernandez-Suarez, M., Fortune, S. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms2745 · Cited by 189
“16 The sample volume per measurement was 1 μL.”
InfluentialSelf-citationPotential applications and human biosafety of nanomaterials used in nanomedicine
Su, H., Wang, Y., Gu, Y., Bowman, L., Zhao, J., & Ding, M. (2018) · Journal of Applied Toxicology · doi:10.1002/jat.3476 · Cited by 178
“A team of investigators from the Massachusetts General Hospital and Harvard Medical School have developed a fast, portable molecular imaging device in combination with magnetic NPs and a smartphone (Haun et al., 2011).”
Metadata
- Authors
- Haun, J. B., Castro, C. M., Wang, R., Peterson, V. M., Marinelli, B. S., Lee, H., & Weissleder, R.
- Venue
- Science Translational Medicine
- Published
- 2011-02-23
- Volume
- 3
- Issue
- 71
- Pages
- 71ra16-71ra16
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2155472653
- Cited by
- 214
- References
- 9
- FWCI
- 12.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.