Vascular Catheters with a Nonleaching Poly-Sulfobetaine Surface Modification Reduce Thrombus Formation and Microbial Attachment
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Poly-sulfobetaine surface modification on a vascular catheter inhibits microbial adherence and thrombosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Antibiotic resistance of bacteria in biofilms
Stewart, P. S., & William Costerton, J. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05321-1 · Cited by 4,585
Hirsh, J., Warkentin, T. E., Shaughnessy, S. G., Anand, S. S., Halperin, J. L., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (2001) · Chest · doi:10.1378/chest.119.1_suppl.64s · Cited by 1,580
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Overview of Nosocomial Infections Caused by Gram-Negative Bacilli
Weinstein, R. A., Gaynes, R., Edwards, J. R., & System, N. N. I. S. (2005) · Clinical Infectious Diseases · doi:10.1086/432803 · Cited by 1,404
Harder, P., Grunze, M., Dahint, R., Whitesides, G. M., & Laibinis, P. E. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp972635z · Cited by 1,290
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919 · cited 1×
“ScienceTra tient care cost and have an associated mortality of 12 to 25% annually (8, 9).”
BackgroundPrevention of Intravascular Catheter-Related Infections
(2021) · Indian Journal of Continuing Nursing Education · doi:10.4103/2230-7354.320831 · Cited by 855
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Cited by
Lebeaux, D., Ghigo, J.-M., & Beloin, C. (2014) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00013-14 · Cited by 1,318
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897
Self-citationLi, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
Leslie, D. C., Waterhouse, A., Berthet, J. B., Valentin, T. M., Watters, A. L., Jain, A., Kim, P., Hatton, B. D., Nedder, A., Donovan, K., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.3020 · Cited by 758
Biomaterial-Associated Infection: Locating the Finish Line in the Race for the Surface
Busscher, H. J., van der Mei, H. C., Subbiahdoss, G., Jutte, P. C., van den Dungen, J. J. A. M., Zaat, S. A. J., Schultz, M. J., & Grainger, D. W. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004528 · Cited by 707
Russo, M. J., Han, M., Desroches, P. E., Manasa, C. S., Dennaoui, J., Quigley, A. F., Kapsa, R. M. I., Moulton, S. E., Guijt, R. M., Greene, G. W., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00390 · Cited by 338
Zhang, P., Sun, F., Tsao, C., Liu, S., Jain, P., Sinclair, A., Hung, H.-C., Bai, T., Wu, K., & Jiang, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1512465112 · Cited by 316
Emerging rules for effective antimicrobial coatings
Salwiczek, M., Qu, Y., Gardiner, J., Strugnell, R. A., Lithgow, T., McLean, K. M., & Thissen, H. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.09.008 · Cited by 312
Microgel reinforced zwitterionic hydrogel coating for blood-contacting biomedical devices
Yao, M., Wei, Z., Li, J., Guo, Z., Yan, Z., Sun, X., Yu, Q., Wu, X., Yu, C., Yao, F., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33081-7 · Cited by 311
Self-citationAntimicrobial and Antifouling Strategies for Polymeric Medical Devices
Zander, Z. K., & Becker, M. L. (2018) · ACS Macro Letters · doi:10.1021/acsmacrolett.7b00879 · Cited by 310
Implantable Device-Related Infection
VanEpps, J. S., & Younger, J. G. (2016) · Shock · doi:10.1097/shk.0000000000000692 · Cited by 306
Wang, X., Shan, M., Zhang, S., Chen, X., Liu, W., Chen, J., & Liu, X. (2022) · Advanced Science · doi:10.1002/advs.202104843 · Cited by 245
Zwitterionically modified alginates mitigate cellular overgrowth for cell encapsulation
Liu, Q., Chiu, A., Wang, L.-H., An, D., Zhong, M., Smink, A. M., de Haan, B. J., de Vos, P., Keane, K., Vegge, A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13238-7 · Cited by 202
All charged up about implanted biomaterials
Grainger, D. W. (2013) · Nature Biotechnology · doi:10.1038/nbt.2600 · Cited by 186
Central venous catheters and biofilms: where do we stand in 2017?
Gominet, M., Compain, F., Beloin, C., & Lebeaux, D. (2017) · APMIS · doi:10.1111/apm.12665 · Cited by 185
A retrievable implant for the long-term encapsulation and survival of therapeutic xenogeneic cells
Bose, S., Volpatti, L. R., Thiono, D., Yesilyurt, V., McGladrigan, C., Tang, Y., Facklam, A., Wang, A., Jhunjhunwala, S., Veiseh, O., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0538-5 · Cited by 172
Self-citationAntimicrobial Drugs in Fighting against Antimicrobial Resistance
Cheng, G., Dai, M., Ahmed, S., Hao, H., Wang, X., & Yuan, Z. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.00470 · Cited by 165
Novel approaches to combat bacterial biofilms
Beloin, C., Renard, S., Ghigo, J.-M., & Lebeaux, D. (2014) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2014.09.005 · Cited by 160
Metadata
- Authors
- Smith, R. S., Zhang, Z., Bouchard, M., Li, J., Lapp, H. S., Brotske, G. R., Lucchino, D. L., Weaver, D., Roth, L. A., Coury, A., Biggerstaff, J., Sukavaneshvar, S., Langer, R., & Loose, C.
- Venue
- Science Translational Medicine
- Published
- 2012-09-26
- Volume
- 4
- Issue
- 153
- Pages
- 153ra132-153ra132
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2158916943
- Cited by
- 221
- References
- 29
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.