An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs
The DOI matches its Crossref record; 43 of the 45 references it cites were found in a registry or an index.
Abstract
An osseointegrated interface allowed long-term stable and bidirectional communication between robotic prostheses and implanted neuromuscular electrodes for intuitive control with sensory feedback in one patient.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In contrast, surface electrodes generally are more flexible,[364,369] whose morphology in the limited space between this epimysium and the skin is either 1D or 2D thin electrode layers[370,371] or very tiny electrodes (millimeter or even sub-millimeter level).[369,372]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [370]
In the citing paper
“Its recording ability (Yoo and Durand, 2005) and selectivity of the periphery of the stimulated nerve have been demonstrated (Schiefer et al., 2013; Ortiz-Catalan et al., 2014).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Ortiz-Catalan et al., 2014
In the citing paper
“and that long-term stability and selectivity has demonstrated using FINE (Ortiz-Catalan et al., 2014; Tan et al., 2014).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Ortiz-Catalan et al., 2014
Citations
Cites
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Osseointegration in skeletal reconstruction and rehabilitation: a review.
Brånemark, R., Brånemark, P., Rydevik, B. L., & Myers, R. R. (2001) · PubMed · Cited by 664
Self-citationDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573 · cited 1×
“However, acute studies using intrafascicular electrodes have suggested that motor nerve fibers remain viable in long-term amputees despite cortical reorganization and axotomy-induced degeneration (3, 22).”
BackgroundOchoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466 · cited 1×
“Here, we show that by incorporating signal feedthrough mechanisms into the osseointegrated implant system, long-term bidirectional communication between the artificial limb and implanted neuromuscular interfaces is possible, thus improving controllability in comparison with surface electrodes and enabling sensory feed…”
BackgroundDoes use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain?
Lotze, M., Grodd, W., Birbaumer, N., Erb, M., Huse, E., & Flor, H. (1999) · Nature Neuroscience · doi:10.1038/9145 · Cited by 387 · cited 4×
“M. Ortiz-Catalan, N. Sander, M. B. Kristoffersen, B. Håkansson, R. Brånemark, Treatment of phantom limb pain (PLP) based on augmented reality and gaming controlled by myoelectric pattern recognition: A case study of a chronic PLP. Front.”
ResultInfluentialDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Research works printed but not linked: 1
- 10.1682/jrrd.2008.06.0080 · doi:10.1682/jrrd.2008.06.0080
Cited by
Items 301–400 of 494
Hargrove, L. J. (2017) · Springer eBooks · doi:10.1007/978-1-4939-7247-0_8 · Cited by 7
Novel Control Strategies for Upper Limb Prosthetics
Vujaklija, I. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_34 · Cited by 7
Bertos, G. A., & Papadopoulos, E. G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00006-4 · Cited by 8
Kontogiannopoulos, S., Bertos, G. A., & Papadopoulos, E. G. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2980077 · Cited by 7
“ing the proprioceptive feedback transmitted via the implant which is rigidly integrated with the amputee’s bone [60].”
BackgroundW:Ti Flexible Transversal Electrode Array for Peripheral Nerve Stimulation: A Feasibility Study
Silveira, C. R. A., Brunton, E., Escobedo‐Cousin, E., Gupta, G., Whittaker, R. G., O'Neill, A. G., & Nazarpour, K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3014812 · Cited by 7
“peripheral nervous system [2], [15]–[17]; invasive [2], [7], [8], [10], [18] vs.”
Evolutionary perspective on peripersonal space and perception
Froesel, M., Hamed, S. B., & Cléry, J. C. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99193-3.00009-x · Cited by 7
Smiles, A. B., Earley, E. J., Jiang, N., & Ortiz-Catalan, M. (2024) · Prosthesis · doi:10.3390/prosthesis7010003 · Cited by 6
Self-citationPeripheral Neuroergonomics – An Elegant Way to Improve Human-Robot Interaction?
Vecchio, A. D., Castellini, C., & Beckerle, P. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.691508 · Cited by 6
“Ultrasound scanning and electromyographic sensors implanted during osseointegration (Ortiz-Catalan et al., 2014) or injected into the muscles (Becerra-Fajardo and Ivorra, 2019) offer high signal-to-noise ratios while entailing rather low risk.”
BackgroundEarley, E. J., & Ortiz-Catalan, M. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123893 · Cited by 6
“The purpose of this study is to evaluate the relationship between the minimum required neurostimulation pulse amplitude and duration at perception thresholds using a strength-duration curve framework for three individuals receiving nerve cuff stimulation with an implanted neuromusculoskeletal prosthesis system [16], […”
MethodSelf-citationSensory integration for neuroprostheses: from functional benefits to neural correlates
Ding, K., Rakhshan, M., Paredes-Acuña, N., Cheng, G., & Thakor, N. V. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03118-8 · Cited by 7
Electrical Neurostimulation Promotes Brown Adipose Tissue Thermogenesis
Zhuang, L., de Jonge, W. J., Wang, Y., Rensen, P. C. N., & Kooijman, S. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.567545 · Cited by 6
“Electrical stimulation of peripheral nerves is already applied in a variety of conditions in humans (17, 18).”
BackgroundWhat microsurgeon, orthopaedic and plastic surgeon should know about bionic hand
Bumbaširević, M., Lešić, A., Palibrk, T., Georgescu, A. V., Matei, I. R., Vučetić, Č., Pierluigi, T., Matić, S., Damjanovic, D., & Raspopović, S. (2019) · Injury · doi:10.1016/j.injury.2019.10.065 · Cited by 6
Pan, L., & Huang, H. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102509 · Cited by 7
Millevolte, A. X. T., Dingle, A. M., Ness, J. P., Novello, J., Zeng, W., Lü, Y., Minor, R. L., Nemke, B. W., Markel, M. D., Suminski, A. J., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.613844 · Cited by 6
Gherardini, M., Sturma, A., Boesendorfer, A., Ianniciello, V., Mannini, A., Aszmann, O. C., & Cipriani, C. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3181748 · Cited by 6
Nanivadekar, A. C., Bose, R., Petersen, B. A., Okorokova, E. V., Sarma, D., Farooqui, J., Dalrymple, A. N., Levy, I., Helm, E. R., Mièle, V., et al. (2022) · medRxiv · doi:10.1101/2022.09.15.22279956 · Cited by 8
Artificial nerve systems for use in bio-interactive prostheses
Kim, C. H., Seo, D., Lee, Y., & Lee, T. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00197-z · Cited by 6
“Early attempts at the restoration of sensation focused on adjusting the amplitude, frequency and pulse width of stimulation 58,59,61 .”
Our research path toward the restoration of natural sensations in hand prostheses
Micera, S., & Shokur, S. (2024) · Artificial Organs · doi:10.1111/aor.14823 · Cited by 7
Leung, E. S., & Mofatteh, M. (2025) · Cureus · doi:10.7759/cureus.82567 · Cited by 7
“Percutaneous osseointegrated interfaces provide a stable and continuous bidirectional communication channel using implanted electrodes in the peripheral nerves and muscles [5].”
InfluentialReinnervated Split-Muscle Technique for Creating Additional Myoelectric Sites in an Animal Model
Deslivia, M. F., Lee, H., Zulkarnain, R. F., Zhu, B., Adikrishna, A., Jeon, I.-H., & Kim, K. (2016) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000002768 · Cited by 5
Dingle, A. M., Ness, J. P., Novello, J., Zeng, W., Millevolte, A. X. T., Minor, R. L., Kegal, J., Lü, Y., Nemke, B. W., Markel, M. D., et al. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716957 · Cited by 5
“use of osseointegration as a direct conduit for connecting implanted PNIs with a prosthesis, and indicates the need for additional surgical techniques to create the PNI [8].”
MethodInfluentialDennis, W., & Alawi, S. A. (2019) · WORLD JOURNAL OF PLASTIC SURGERY · doi:10.29252/wjps.8.2.146 · Cited by 5
Amputation Surgeries for the Lower Limb
Grimm, P. D., & Potter, B. K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-60913-5.00019-2 · Cited by 5
Clinical Basis for Creating an Osseointegrated Neural Interface
Karczewski, A. M., Zeng, W., Stratchko, L. M., Bachus, K. N., Poore, S. O., & Dingle, A. M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.828593 · Cited by 5
Cross-Channel Impedance Measurement for Monitoring Implanted Electrodes
Earley, E. J., Mastinu, E., & Ortiz-Catalan, M. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871954 · Cited by 5
“Implantable sensors, such as the epimysial, intramuscular, and cuff electrodes often used in prosthetic limb control [1], [2] and the microelectrode arrays used with neural tissues [3]–[5], are typically made of biologically inert materials such as platinum, titanium, or tungsten to maximize biocompatibility and reduc…”
BackgroundSelf-citationThe Shape of Things to Come: The Military Benefits of the Brain-Computer Interface in 2040
Cutter, P. A. (2015) · Defense Technical Information Center (DTIC) · doi:10.21236/ad1012768 · Cited by 7
Restoration of somatosensory perception via electrical stimulation of peripheral nerves
Ortiz-Catalan, M. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.008 · Cited by 5
“Whereas it is currently possible to elicit long-term stable, intuitive percepts (Graczyk et al., 2016; Ortiz-Catalan et al., 2014; Tan et al., 2014), the challenge of providing a completely natural sensory experience persists.”
BackgroundSelf-citationToward self-contained bidirectional bionic limbs with high information throughput
Dosen, S. S. (2023) · Science Robotics · doi:10.1126/scirobotics.adk6086 · Cited by 4
Bose, R., Petersen, B. A., Sarma, D., Barra, B., Nanivadekar, A. C., Madonna, T. J., Liu, M., Levy, I., Helm, E. R., Mièle, V., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae16d7 · Cited by 5
“Collectively, these works have demonstrated that providing somatosensory feedback from the missing limb can improve standing and walking, as determined by clinical assessments of balance and gait [8–10 , 12].”
Overstreet, C. K., Hellman, R. B., Wong, R. D. P., Santos, V. J., & Tillery, S. I. H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00091 · Cited by 4
“org December 2016 | Volume 4 | Article 91 that interfaces with peripheral nerves can provide a robust and stable sensory percept that is useful for movement (Ortiz-Catalan et al., 2014; Raspopovic et al., 2014; Tan et al., 2014; Oddo et al., 2016).”
BackgroundUnidirectional ephaptic stimulation between two myelinated axons
Capllonch-Juan, M., Kölbl, F., & Sepulveda, F. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036804 · Cited by 7
“To date, some first achievements have already been obtained by others with the same purpose [2], [3].”
BackgroundTang, R., Lv, X., Sun, W., Dai, C., Zhang, M., Li, X., She, H., Zhang, X., Lang, Y., Zhu, J., et al. (2017) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2017.8266089 · Cited by 4
“There are demonstrations of invasive neural interface devices in laboratory [19]-[20] and clinical circumstances [21]-[21], it is still not accepted for general clinical use in part to the risk of infection, tethering issues and serious safety concern with brain surgery.”
BackgroundMatlab software for impedance spectroscopy designed for neuroscience applications
Maghsoudi, O. H., Vahedipour, A., Gerstenhaber, J. A., George, S. P., Hallowell, T., Robertson, B., Short, M., & Spence, A. J. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.06.020 · Cited by 6
Regenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_18-1 · Cited by 5
A Computer-Brain Interface that Restores Lost Extremities’ Touch and Movement Sensations
Valle, G., Petrini, F. M., Mijović, P., Mijović, B., & Raspopović, S. (2021) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-79287-9_7 · Cited by 5
Peripheral Nervous System Interfaces: Invasive or Non-invasive?
Castellini, C. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.846866 · Cited by 5
Osumi, M., Sumitani, M., Otake, Y., Nishi, Y., Nobusako, S., & Morioka, S. (2022) · Experimental Brain Research · doi:10.1007/s00221-022-06532-2 · Cited by 4
“Previous studies reported that somatosensory feedback with electrical stimulation using implanted peripheral nerve cuff electrodes not only evoked artificial touch sensation but also improved the ability to manipulate delicate objects with a prosthesis (Tan et al. 2014; Ortiz-Catalan et al. 2014).”
BackgroundMonitoring at-home prosthesis control improvements through real-time data logging
Osborn, L. E., Moran, C. W., Dodd, L. D., Sutton, E. E., Acosta, N. N., Wormley, J. M., Pyles, C. O., Gordge, K. D., Nordstrom, M. J., Butkus, J., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7b · Cited by 4
Wilson, L., Dohan, D. P., Garibaldi, M., Szeto, D., Timmerman, M. A., & Matheny, J. (2023) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/20556683231152418 · Cited by 3
Technologies in clinical neurophysiology for brain-body interfacing: IFCN handbook chapter
Cimolato, A., Sparapani, A., & Raspopović, S. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2111913 · Cited by 3
Experimental analysis of the relationship between neural and muscular recordings during hand control
Noce, E., Zollo, L., Davalli, A., Sacchetti, R., & Guglielmelli, E. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523779 · Cited by 3
“it There is clear evidence in the literature [6] [7] [8] [9] that through neural electrodes it is possible to return a sensory feedback by stimulating the Peripheral Nervous System (PNS) and activating the sensory fascicles of the nerves.”
Background4. Upper and Lower Limb Robotic Prostheses
Pilarski, P. M., & Hebert, J. S. (2017) · Rehabilitation science in practice series · doi:10.1201/9781315368788-5 · Cited by 3
Valle, G. D., Carpaneto, J., & Micera, S. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_27 · Cited by 5
Zhang, J., Chou, C.-H., Hao, M., Li, Y., Yu, Y., & Lan, N. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1298176 · Cited by 3
Zbinden, J., Earley, E. J., & Ortiz-Catalan, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad349c · Cited by 4
“In addition, the patient also received a bone-anchoring implant that allows both for secure attachment and routing of the signals to and from the implanted electrodes—creating a self-contained neuromusculoskeletal prosthesis fit for daily use at home [29, 30].”
BackgroundSelf-citationApproaching Human Hand Dexterity Through Highly Biomimetic Design
Xu, Z. Y. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813385-9.00006-6 · Cited by 3
Chi, A., Smith, S. H., Womack, I., & Armiger, R. S. (2018) · Current Trauma Reports · doi:10.1007/s40719-018-0142-2 · Cited by 3
New surgical options to improve the quality of life of amputees
Kang, N., Woollard, A., & Konczalik, W. (2019) · Surgery (Oxford) · doi:10.1016/j.mpsur.2019.02.007 · Cited by 3
Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle Using a Bone-anchored Device
Lancashire, H. T., Al-Ajam, Y., Dowling, R., Pendegrass, C. J., & Blunn, G. W. (2019) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000002391 · Cited by 4
Restoring the sense of touch with electrical stimulation of the nerve and brain
Callier, T., & Bensmaïa, S. J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00010-1 · Cited by 3
Thesleff, A., Ahkami, B., Anderson, J., Hagberg, K., & Ortiz-Catalan, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629989 · Cited by 3
“This protocol was designed owing to the need of our group to evaluate neuromusculoskeletal prostheses for the lower limb, (the neuromusculoskeletal interface is further described in [21], [22]), but it can be applied to any new leg prostheses and control strategies.”
Self-citationKatic, N., Valle, G. D., & Raspopović, S. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_100-1 · Cited by 3
Anatomics: Co-engineering body and machine in pursuit of synergistic bionic performance
Clites, T. R. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100490 · Cited by 3
Devecıoğlu, İ., & KARAKULAK, E. (2024) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03434-4 · Cited by 3
Development of a hand prosthesis control system with tactile feedback
Yatsun, S. F., Malchikov, A., & Rukavitsyn, A. N. (2024) · Biomedical Engineering · doi:10.1007/s10527-024-10356-5 · Cited by 3
Nguyen, T. D., & Timko, B. P. (2017) · Wiley eBooks · doi:10.1002/9783527689934.ch21 · Cited by 4
Weir, R. F. F. (2017) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000161 · Cited by 3
“A viable osseointegrated interface will enable suspension of device from skeleton with implanted control and feedback signals passing through the abutment—just as demonstrated by Ortiz-Catalan et al.(110) Many users with osseointegrated interfaces claim increased sensation and awareness of their prosthesis.”
Automatic hand phantom map generation and detection using decomposition support vector machines
Huang, H., Bruschini, C. E., Antfolk, C., Enz, C., Li, T., Justiz, J., & Koch, V. M. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0502-8 · Cited by 4
“The invasive approach stimulates the central nervous system using cortical electrodes [6] or the peripheral nervous system using either cuff electrodes [7, 8] or transversal intrafascicular multichannel electrodes [9].”
Sudrajat, A. R. (2021) · Journal of Governance · doi:10.31506/jog.v6i2.12480 · Cited by 3
“…machines, and humans) in the shortest possible time, in real conditions (as long as the situation can change) in real situation or condition (as long as the condition can change) without disturbing the balance between the factors of purpose, tools, effort, and time (Ortiz-Catalan et al., 2014).”
BackgroundWelcome to the Cyborg Olympics
Reardon, S. (2016) · Nature · doi:10.1038/536020a · Cited by 3
Patient Outcomes in a Novel Osseointegrated Device for Transfemoral Amputation: a case series
Hillock, R., Allison, D. C., & Moyer, B. J. (2024) · Journal of Orthopaedic Experience & Innovation · doi:10.60118/001c.91023 · Cited by 2
Paggetti, F., Gherardini, M., Schirru, C., & Cipriani, C. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3601521 · Cited by 2
“…attachment, improving comfort and weight bearing, other than a gateway to muscles and nerves via implanted recording and stimulation electrodes [6]; targeted muscle reinnervation (TMR) [8] and regenerative peripheral nerve interfaces (RPNIs) [9] allowed to increase the number of available…”
Lower limb osseointegrated prosthetics: are we standing on the edge of a new era?
Barootchi, E., Jirofti, N., Daliri, M., & Moradi, A. (2026) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-026-06675-w · Cited by 2
“Regardless of the direct attachment to the bone, the OPRA system has been able to directly interface with the nerves and muscles of the residual limb in a transhumeral amputee, with the patient showing fine motor control such as grasping [41].”
Utilising reinforcement learning to develop strategies for driving auditory neural implants
Lee, G. W., Zambetta, F., Li, X., & Paolini, A. G. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046027 · Cited by 2
“In related work Tan et al [29] and Max Ortiz-Catalan et al [13] used neural implants to restore neural sensation to prosthetic limbs, however a low resolution of electrodes and no learning algorithm meant it was up to neural plasticity to re-learn stimulation provided.”
BackgroundDifferential Activation of Biceps Brachii Muscle Compartments for Human-Machine Interfacing
Lendaro, E., Nilsson, S., & Ortiz-Catalan, M. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513103 · Cited by 2
Self-citationBiomimetic bidirectional hand neuroprostheses for restoring somatosensory and motor functions
Iberite, F., Mendez, V., Mazzoni, A., Shokur, S., & Micera, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00011-3 · Cited by 2
Lang, V. A., Munoz-Novoa, M., & Ortiz-Catalan, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-33210-2 · Cited by 3
“In addition, the superior comfort provided by direct skeletal attachment via osseointegration, as opposed to socket suspension, allows for patients to wear their prosthesis all day and every day 10,11,30 .”
Self-citationGozzi, N., & Valle, G. D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18498-7.00014-4 · Cited by 4
High-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
Piliugin, N., Soghoyan, G. A., Biktimirov, A., Matvienko, Y., Chekh, I., Sintsov, M. Y., Lebedev, M., & Kaplan, A. (2024) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci60775.2024.10480475 · Cited by 3
“Furthermore, prostheses equipped with feedback have shown promising results in suppressing phantom limb pain, a major post-amputation challenge in terms of treatment [9], [10].”
BackgroundBeyond Amputation: Functional Restoration after Upper-Extremity Limb Loss
Bricker, J. T., Bagdady, K. R., Janes, L. E., Souza, J. M., Dumanian, G. A., & Ko, J. H. (2025) · Journal of Hand Surgery Global Online · doi:10.1016/j.jhsg.2025.01.008 · Cited by 2
Scarpelli, A., Cordella, F., & Zollo, L. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade503 · Cited by 2
“Only few studies, monitored a home-use of the sensory encoding schemes [48, 87].”
Sharma, V., Lloyd, E., Faltys, M. A., Ortiz-Catalan, M., & Glass, C. (2025) · Prosthesis · doi:10.3390/prosthesis7040099 · Cited by 2
“It is worth noting that the use of implanted electrodes, as would be the case for Phantom X system, has been shown to mitigate problems related to limb positioning without training for all possible positions [28].”
Self-citationSheshadri, S., Kortelainen, J., Rigosa, J., Cutrone, A., Bossi, S., Libedinsky, C., Lahiri, A., Chan, L., Chng, K., Thakor, N. V., et al. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146692 · Cited by 2
“Several solutions have been developed for hand prosthesis in the recent past[12–13].”
Human–machine interfaces expand the functionality of prosthetic limbs
Wood, H. B. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.212 · Cited by 2
Automatic hand phantom map detection methods
Huang, H., Li, T., Antfolk, C., Bruschini, C. E., Enz, C., Justiz, J., & Koch, V. M. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348315 · Cited by 2
“Invasive feedback stimulates the central nervous system using cortical electrodes [8] or the peripheral nervous system using for example cuff electrodes [9], [10] or transversal intrafascicular multichannel electrodes [11].”
MethodNeural electrodes for long-term tissue interfaces
del Valle, J., Rodríguez‐Meana, B., & Navarro, X. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00009-5 · Cited by 2
Research on Joint-Angle Prediction Based on Artificial Neural Network for Above-Knee Amputees
Yang, J., Li, G., Zhao, X., & Xie, H. (2021) · Sensors · doi:10.3390/s21217199 · Cited by 2
Devecıoğlu, İ. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-02978-1 · Cited by 2
Gantenbein, J., Meyer, J. T., Jäger, L., Sigrist, R., Gassert, R., & Lambercy, O. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896539 · Cited by 2
“, targeted muscle innervation or implanted electrodes, might be sufficient to achieve good performance, as presented by some participating teams using such techniques [24].”
BackgroundRiccio-Ackerman, F., Chicos, L., & Herrera-Arcos, G. (2023) · MIT Science Policy Review · doi:10.38105/spr.4ffmn3soar · Cited by 5
Mialland, A., Atallah, I., & Bonvilain, A. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3336960 · Cited by 3
Osborn, L. E., Betthauser, J., & Thakor, N. V. (2019) · Wiley eBooks · doi:10.1002/047134608x.w1424.pub2 · Cited by 4
Robotic prosthetic hands - A reviewPreprint
Ubosi, D. (2023) · TechRxiv · doi:10.36227/techrxiv.24103386.v1 · Cited by 2
A Robust Neuromuscular Interface to Restore Lost Function in People with AmputationsPreprint
Vaskov, A. K., Wallace, D. M., Desai, K., Laidlaw, A. T., Kung, T. A., Gates, D. H., Kemp, S. W. P., Chestek, C. A., & Cederna, P. S. (2025) · Research Square · doi:10.21203/rs.3.rs-5989030/v1 · Cited by 2
Upper limb prostheses control based on user's body compensations
Legrand, M. L. (2021) · theses.fr (ABES) · doi:10.70675/ed6006b7zd285z46deza981zccb011324956 · Cited by 6
Prosthetic Care for the Mangled Extremity
Rheinstein, J., Carroll, K., & Stevens, P. M. (2021) · Springer eBooks · doi:10.1007/978-3-319-56648-1_17 · Cited by 2
Regenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_18 · Cited by 1
BICEP: A Bio-Inspired Compliant Elbow Prosthesis
Castañeda, T. S., Horstman, B., Capsi‐Morales, P., Santina, C. D., & Piazza, C. (2024) · Springer proceedings in advanced robotics · doi:10.1007/978-3-031-55000-3_3 · Cited by 1
State of the art for prosthetic reconstruction of the upper limb
Kang, N. (2024) · Bulletin of The Royal College of Surgeons of England · doi:10.1308/rcsbull.2024.150 · Cited by 2
A wireless magnetic implant system for continuous neuromuscular sensing
Shallal, C., Taylor, C. R., Yeon, S. H., Casler, R. J., Oseyemi, D., Herrera-Arcos, G., Qiao, J., Shu, T., Xu, J., Levine, D., et al. (2026) · Nature Sensors · doi:10.1101/2025.11.17.25340274 · Cited by 3
Self-citationCady, S. R., Lambrecht, J. M., & Tyler, D. J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae24ae · Cited by 1
“Peripheral nerve stimulation using implanted extraneural or intraneural electrodes can elicit somatosensory percepts of varying intensities, qualities, durations, and locations in the missing hand [2–7], representing variation along the four dimensions of perception.”
Damonte, F., Gaudio, L. A., Gonzalez-Vargas, J. E., Durandau, G., Ernst, J., Rietman, J. S., Leijendekkers, R. A., van der Kooij, H., & Sartori, M. (2026) · PNAS Nexus · doi:10.1093/pnasnexus/pgaf413 · Cited by 1
“…control across various locomotion tasks (19) with respect to non-AMI individuals with traditional socket-suspended prostheses (18, 20, 21), it remains unclear how myoelectric control paradigms for bionic legs would translate to non-AMI bionic leg users with bone-anchored prostheses (BAP) (22, 23).”
The proprioception illusion can simulate limb movement in persons with limb difference
Leskovar, R., Kyberd, P., Moore, J. M., Exell, T., & Ostler, C. (2026) · Scientific Reports · doi:10.1038/s41598-025-30687-x · Cited by 1
Sensing Muscle Deformation for Upper-Limb Prosthetic Control: A Narrative Review
Paggetti, F., Gherardini, M., Tian, Y., Cederna, P. S., Kemp, S. W. P., & Cipriani, C. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3710283 · Cited by 1
Targeted Muscle Reinnervation for Intuitive Prosthetic Control
Maile, N., Ferrante, L., Farina, D., Dabbass, U. A., Aszmann, O. C., & Tereshenko, V. (2026) · Muscle & Nerve · doi:10.1002/mus.70340 · Cited by 2
Optimisation of the spatial discretisation of myelinated axon models
Juan, M. C., Kölbl, F., & Sepulveda, F. (2016) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec.2016.7835916 · Cited by 1
“Recently, attempts at enhancing such prosthetics by providing sensory feedback have been successfully conducted [1] [2] [3].”
BackgroundOsseointegrated Amputation Prostheses and Implanted Electrodes
Li, Y., Ortiz-Catalan, M., & Brånemark, R. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_6 · Cited by 1
Self-citationNeural Interface Activates a Sense of Touch in Prosthetic Limbs
Talan, J. (2014) · Neurology Today · doi:10.1097/01.nt.0000457142.45399.80 · Cited by 1
Artificial Limbs for Upper Extremity Amputation
Marasco, P. D., Hebert, J. S., & Orzell, B. M. (2015) · Springer eBooks · doi:10.1007/978-1-4939-2671-8_49 · Cited by 1
Metadata
- Authors
- Ortiz-Catalan, M., Håkansson, B., & Brånemark, R.
- Affiliations
- Sahlgrenska University Hospital (SE)
- Chalmers University of Technology (SE)
- Corresponding author
- Ortiz-Catalan, Max
- Venue
- Science Translational Medicine
- Published
- 2014-10-08
- Volume
- 6
- Issue
- 257
- Pages
- 257re6-257re6
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2101843765
- Cited by
- 484
- References
- 45
- Citations by year
- 2026: 30 · 2025: 30 · 2024: 43 · 2023: 52 · 2022: 43 · 2021: 57 · 2020: 52 · 2019: 51 · 2018: 42 · 2017: 36 · 2016: 29 · 2015: 15 · 2014: 4
- FWCI
- 12.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- Chalmers Research (Chalmers University of Technology) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- osseointegration, artificial limbs, peripheral nerve stimulation, myoelectric pattern recognition, sensory feedback, amputees, implanted electrodes, long-term stability, human-machine interaction
- MeSH terms
- Activities of Daily Living, Amputees, Artificial Limbs, Electrodes, Implanted, Electromyography, Humans, Prosthesis Design, Range of Motion, Articular, Osseointegration, Touch Perception, Feedback, Sensory, Translational Research, Biomedical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.