Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Despite the technological progress in robotics achieved in the last decades, prosthetic limbs still lack functionality, reliability, and comfort. Recently, an implanted neuromusculoskeletal interface built upon osseointegration was developed and tested in humans, namely the Osseointegrated Human-Machine Gateway. Here, we present an embedded system to exploit the advantages of this technology. Our artificial limb controller allows for bioelectric signals acquisition, processing, decoding of motor intent, prosthetic control, and sensory feedback. It includes a neurostimulator to provide direct neural feedback based on sensory information. The system was validated using real-time tasks characterization, power consumption evaluation, and myoelectric pattern recognition performance. Functionality was proven in a first pilot patient from whom results of daily usage were obtained. The system was designed to be reliably used in activities of daily living, as well as a research platform to monitor prosthesis usage and training, machine-learning-based control algorithms, and neural stimulation paradigms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“signal features are extracted from the acquired EMG, such as Mean Absolute Value (MABS), Waveform Length (WL), Slope Changes (SLPCH) and Zero Crossings (ZC) [30].”
MethodElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“phase has been chosen slow to reduce the risk of electrode corrosion [35].”
BackgroundA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“Human-Machine Gateway (OHMG) combines the benefits of skeletal attachment with the reliability and increased information provided by implanted muscular electrodes [13], [14].”
BackgroundA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Self-citationThe Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · cited 1×
“2) interpulse: 50 μs of zero current to allow charges to flow in the tissues [34]; 3) recovery pulse: anodic reversal phase that avoids the po-”
BackgroundOrtiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · cited 1×
“Human-Machine Gateway (OHMG) combines the benefits of skeletal attachment with the reliability and increased information provided by implanted muscular electrodes [13], [14].”
BackgroundSelf-citationMcCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510526 · Cited by 95 · cited 1×
“to limit the frequency of stimulation to 30 Hz as this system is aimed for chronic use [39].”
Background
Research works printed but not linked: 31
- 10.1186/1475-925X-9-41 · DOI · Paper page
- 10.1109/EMBC.2015.7318805 · DOI
- 10.1109/TNSRE.2015.2410176 · DOI
- 10.1109/TNSRE.2011.2163529 · DOI · Paper page
- 10.1186/1751-0473-8-11 · DOI · Paper page
- 10.1109/TBME.2008.919734 · DOI · Paper page
- 10.1080/03093640500238014 · DOI · Paper page
- 10.1007/s10439-011-0265-x · DOI
- 10.1302/0301-620X.96B1.31905 · DOI · Paper page
- clippinger, 1974, A sensory feedback system for an upper-limb amputation prosthesis, Bull Prosthetics Res, 10, 247
- 10.3389/fnins.2016.00312 · DOI
- 10.7554/eLife.09148 · DOI · Paper page
- 10.1088/1741-2560/13/3/036001 · DOI · Paper page
- 10.1016/j.clinbiomech.2008.08.006 · DOI · Paper page
- 10.1016/j.apmr.2003.06.002 · DOI · Paper page
- 10.1109/ReConFig.2015.7393312 · DOI
- østlie, 2012, Prosthesis rejection in acquired major upper-limb amputees: A population-based survey, Disability Rehabil Assistive Technol, 7, 294, 10.3109/17483107.2011.635405 · DOI · Paper page
- 10.1016/j.bspc.2013.12.009 · DOI
- 10.1109/TNSRE.2014.2305111 · DOI · Paper page
- 10.1016/S0140-6736(14)61776-1 · DOI · Paper page
- wirta, 1978, Pattern-recognition arm Prosthesis: A historical porspective—A final report, Bull Prosth Res, 10, 8
- johannes, 0, An overview of the developmental process for the modular prosthetic limb, Proc Johns Hopkins APL Tech Digest (Appl Phys Laboratory), 30, 207
- 10.3109/17453677308989075 · DOI
- 10.1109/IEMBS.2008.4649121 · DOI
- 10.1682/JRRD.2010.09.0177 · DOI · Paper page
- 10.1109/TBME.2011.2155063 · DOI · Paper page
- 10.1108/IR-11-2013-417 · DOI
- 10.1109/TNSRE.2014.2305097 · DOI · Paper page
- 10.1109/AIM.2011.6027110 · doi:10.1109/aim.2011.6027110
- xiaorong, 0, Implementing an FPGA system for real-time intent recognition for prosthetic legs, Proc Des Autom Conf, 169
- 10.1109/TBCAS.2015.2476555 · DOI · Paper page
Cited by
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-Contained Neuromusculoskeletal Arm Prostheses
Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O., & Brånemark, R. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1917537 · Cited by 256
Self-citationSafety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
Self-citationMastinu, E., Clemente, F., Sassu, P., Aszmann, O., Brånemark, R., Håkansson, B., Controzzi, M., Cipriani, C., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0511-2 · Cited by 87
Self-citation
Metadata
- Authors
- Mastinu, E., Doguet, P., Botquin, Y., Hakansson, B., & Ortiz-Catalan, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2017-08
- Volume
- 11
- Issue
- 4
- Pages
- 867-877
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2619944123
- Cited by
- 97
- References
- 11
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- Swedish Research Council (Vetenskapsrdet)
- VINNOVA
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant. https://app.cochat.ai/papers/10.1109/tbcas.2017.2694710
- The paper
- Mastinu, E., Doguet, P., Botquin, Y., Hakansson, B., & Ortiz-Catalan, M. (2017). Embedded System for Prosthetic Control Using Implanted Neuromuscular Interfaces Accessed Via an Osseointegrated Implant. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2017.2694710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.