The DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
Enhancing functional abilities and cognitive integration of the lower limb prosthesis
Open accessAbstract
Recreated missing leg sensations, connected to the prosthesis sensors, restored leg functional abilities and promoted its cognitive integration.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In regard to lower limb amputees, a recent trial has documented the qualification of TIME electrodes in improving functional abilities, cognitive ease in dual-tasks, and prosthesis embodiment [102].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [102]
Citations
Cites
Updating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
The P300 wave of the human event-related potential
Picton, T. W. (1992) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199210000-00002 · Cited by 1,908
Multisensory brain mechanisms of bodily self-consciousness.
Blanke, O. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3292 · Cited by 1,147
Dynamic Sensorimotor Interactions in Locomotion
Rossignol, S., Dubuc, R., & Gossard, J.-P. (2006) · Physiological Reviews · doi:10.1152/physrev.00028.2005 · Cited by 1,096
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationEnergy cost of walking of amputees: the influence of level of amputation.
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · PubMed · Cited by 873
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“We engineered wireless communication modules to control the parameters of PNES with a latency of less than 50 ms. Petrini et al., Sci. Transl.”
BackgroundSelf-citationEnergy cost of walking of amputees
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197658010-00007 · Cited by 840
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Decoding the organization of spinal circuits that control locomotion
Kiehn, O. (2016) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.9 · Cited by 742
Research works printed but not linked: 1
- 10.1682/JRRD.2008.01.0007 · DOI
Cited by
Sorted by citations
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Self-citationSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Self-citationPlasmodium asexual growth and sexual development in the haematopoietic niche of the host
Venugopal, K., Hentzschel, F., Valkiūnas, G., & Marti, M. (2020) · Nature Reviews Microbiology · doi:10.1038/s41579-019-0306-2 · Cited by 289
Extracellular vesicles as a drug delivery system: A systematic review of preclinical studies
de Castilla, P. E. M., Tong, L., Huang, C., Sofias, A. M., Pastorin, G., Chen, X. S., Storm, G., Schiffelers, R. M., & Wang, J. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.011 · Cited by 219
Metadata
- Authors
- Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., Divoux, J.-L., Popovic, I., Lechler, K., Mijovic, B., Guiraud, D., Stieglitz, T., Alexandersson, A., Micera, S., Lesic, A., & Raspopovic, S.
- Affiliations
- ETH Zurich (CH)
- Scuola Superiore Sant'Anna (IT)
- Orthopaedic Surgery Department, School of Medicine, University of Belgrade, 11000 Belgrade, Serbia.
- Politecnico di Milano (IT)
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering, University of Freiburg—IMTEK, 79110 Freiburg, Germany.
- Institut national de recherche en sciences et technologies du numérique (FR)
- mBrainTrain d.o.o., 11000 Belgrade, Serbia.
- Össur (Iceland) (IS)
- Axonic, 06220 Vallauris, France.
- Specialized hospital for rehabilitation and orthopaedic prosthetics, 11000 Belgrade, Serbia.
- University of Freiburg (DE)
- Össur hf., R&D, 110 Reykjavik, Iceland.
- Laboratory for Neuroengineering, Department of Health Sciences and Technology, Institute for Robotics and Intelligent Systems, ETH Zürich, 8092 Zürich, Switzerland.
- Corresponding author
- Petrini, Francesco Maria
- Valle, Giacomo
- Micera, Silvestro
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2019-10-02
- Volume
- 11
- Issue
- 512
- Pages
- eaav8939
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2977579781
- Cited by
- 265
- References
- 56
- Citations by year
- 2026: 18 · 2025: 32 · 2024: 28 · 2023: 35 · 2022: 29 · 2021: 76 · 2020: 42 · 2019: 5
- FWCI
- 13.41
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Licence
- cc-by-nc-nd
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Repository for Publications and Research Data (ETH Zurich) (submittedVersion, other-oa)
- ETH Zürich Research Collection
- Funders
- H2020 European Research Council (759998)
- H2020 Future and Emerging Technologies (754497)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- lower limb prosthesis, transfemoral amputation, sensory feedback, neurostimulation, neural prostheses, proprioception, tactile feedback, embodiment, cognitive effort, dual-task performance, fall prevention, mobility (physical function)
- MeSH terms
- Activities of Daily Living, Amputees, Artificial Limbs, Cognition, Humans, Knee Joint, Prosthesis Design, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review