Sampling interstitial fluid from human skin using a microneedle patch
Open accessThe DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Abstract
Interstitial fluid from skin sampled with a microneedle-based method identified clinically relevant metabolic biomarkers in humans compared to plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
Sumner, L. W., Amberg, A., Barrett, D., Beale, M. H., Beger, R., Daykin, C. A., Fan, T. W.-M., Fiehn, O., Goodacre, R., Griffin, J. L., et al. (2007) · Metabolomics · doi:10.1007/s11306-007-0082-2 · Cited by 5,368
KEGG for integration and interpretation of large-scale molecular data sets
Kanehisa, M., Goto, S., Sato, Y., Furumichi, M., & Tanabe, M. (2012) · Nucleic Acids Research · doi:10.1093/nar/gkr988 · Cited by 4,848
Lipidomics reveals a remarkable diversity of lipids in human plasma
Quehenberger, O., Armando, A. M., Brown, A. H., Milne, S. B., Myers, D. S., Merrill, A. H., Bandyopadhyay, S., Jones, K. N., Kelly, S., Shaner, R. L., et al. (2010) · Journal of Lipid Research · doi:10.1194/jlr.m009449 · Cited by 1,341
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183 · cited 1×
“If future work were to identify a significant increase in sodium concentration, this could alter osmotically driven flow of ISF in the skin, which could, in turn, alter ISF composition (44).”
Backgroundγ-Tocopherol, the major form of vitamin E in the US diet, deserves more attention
Jiang, Q., Christen, S., Shigenaga, M. K., & Ames, B. N. (2001) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/74.6.714 · Cited by 776 · cited 1×
“Tocopherol 2 Form of vitamin E, micronutrient (75) 5% 100% 0%”
BackgroundAccessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Effect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701
Self-citationHyponatremia: evaluating the correction factor for hyperglycemia
Hillier, T. A., Abbott, R. D., & Barrett, E. J. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00055-8 · Cited by 567
Price, M. J., Ades, A., Soldan, K., Welton, N. J., Macleod, J., Simms, I., DeAngelis, D., Turner, K. M., & Horner, P. J. (2016) · Health Technology Assessment · doi:10.3310/hta20220 · Cited by 494
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Magneto‐Responsive Microneedle Robots for Intestinal Macromolecule Delivery
Zhang, X., Chen, G., Fu, X., Wang, Y., & Zhao, Y. (2021) · Advanced Materials · doi:10.1002/adma.202104932 · Cited by 263
Microneedle biomedical devices
Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00141-6 · Cited by 235
“The first mechanism is to use solid MNs to poke the skin, followed by the removal of MNs and suction of ISF from the skin microchannels using a vacuum 81 or liquid-absorbing paper 82 .”
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
Smits, A., Annaert, P., Cavallaro, G., De Cock, P. A. J. G., de Wildt, S. N., Kindblom, J. M., Lagler, F. B., Moreno, C., Pokorna, P., Schreuder, M. F., et al. (2022) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.14958 · Cited by 55
“In adults, microneedle-based ISF from human skin was collected to quantify selected biomarkers, and was well tolerated.(108)”
MethodInfluentialA microneedle device for rapid dermal interstitial fluid sampling
Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5492 · Cited by 22
A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Hung, A. H., Rajesh, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · doi:10.1101/2025.03.13.641882 · Cited by 22
Kim, J., Kim, M. Y., Han, Y., Lee, G. Y., Kim, D. H., Heo, Y. J., & Park, M. (2024) · Talanta · doi:10.1016/j.talanta.2024.126771 · Cited by 18
Metadata
- Authors
- Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R.
- Venue
- Science Translational Medicine
- Published
- 2020-11-25
- Volume
- 12
- Issue
- 571
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W3107908824
- Cited by
- 379
- References
- 82
- FWCI
- 10.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.