CoChat

Safety, Tolerability, and Pharmacokinetics of MEDI4893, an Investigational, Extended-Half-Life, Anti-Staphylococcus aureus Alpha-Toxin Human Monoclonal Antibody, in Healthy Adults

Open access
Yu, Xiang-Qing, Robbie, Gabriel J., Wu, Yuling, Esser, Mark T., Jensen, Kathryn, Schwartz, Howard I., Bellamy, Terramika, Hernandez-Illas, Martha, Jafri, Hasan S. · 2017 · Antimicrobial Agents and Chemotherapy
Cited by 140

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

MEDI4893 is an investigational immunoglobulin G1(κ) monoclonal antibody that specifically binds to and neutralizes alpha-toxin, a key Staphylococcus aureus virulence factor. A triple-amino-acid substitution, M252Y/S254T/T256E, was engineered into the MEDI4893 Fc region to extend its serum half-life. A phase 1, double-blind, dose escalation study was designed to evaluate the safety, tolerability, pharmacokinetics, anti-alpha-toxin-neutralizing activity, and antidrug antibody (ADA) response of MEDI4893 following a single intravenous infusion in healthy adults 18 to 65 years of age. Thirty-three subjects were randomly assigned to receive MEDI4893 at 225 mg ( n = 3), 750 mg ( n = 3), 2,250 mg ( n = 8), or 5,000 mg ( n = 12) or placebo ( n = 7) and were followed for 360 days. Adverse events were mild or moderate in severity; none were serious. The MEDI4893 peak serum concentration increased dose proportionally from 77.2 μg/ml (225-mg dose) to 1,784 μg/ml (5,000-mg dose). The area under the concentration-time curve from 0 to 360 days also increased dose proportionally, from 4,840 μg · day/ml (225-mg dose) to 91,493 μg · day/ml (5,000-mg dose), indicating linear pharmacokinetics. MEDI4893's terminal half-life was estimated to be 80 to 112 days, which is approximately 4-fold longer than the half-lives of other human immunoglobulin G antibodies. The alpha-toxin-neutralizing activity in serum correlated highly with the MEDI4893 concentrations in serum. Three adults transiently tested positive for ADA on day 151, but this did not have an impact on MEDI4893 serum concentrations or the MEDI4893 safety profile; no subjects exhibited serum ADA at the study end. These data support the continued development of MEDI4893 for the prevention of S. aureus -mediated pneumonia. (This study has been registered at ClinicalTrials.gov under identifier NCT02296320.)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/aac.01020-16

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Yu, X.-Q., Robbie, G. J., Wu, Y., Esser, M. T., Jensen, K., Schwartz, H. I., Bellamy, T., Hernandez-Illas, M., & Jafri, H. S.
Venue
Antimicrobial Agents and Chemotherapy
Published
2017-01
Volume
61
Issue
1
ISSN
  • 0066-4804 (ISSN-L)
  • 1098-6596
OpenAlex
W2535198463
Cited by
140
References
8
FWCI
9.99
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.