Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
SUMMARY: Molecular technology has changed the way that clinical laboratories diagnose and manage many infectious diseases. Excellent sensitivity, specificity, and speed have made molecular assays an attractive alternative to culture or enzyme immunoassay methods. Many molecular assays are commercially available and FDA approved. Others, especially those that test for less common analytes, are often laboratory developed. Laboratories also often modify FDA-approved assays to include different extraction systems or additional specimen types. The Clinical Laboratory Improvement Amendments (CLIA) federal regulatory standards require clinical laboratories to establish and document their own performance specifications for laboratory-developed tests to ensure accurate and precise results prior to implementation of the test. The performance characteristics that must be established include accuracy, precision, reportable range, reference interval, analytical sensitivity, and analytical specificity. Clinical laboratories are challenged to understand the requirements and determine the types of experiments and analyses necessary to meet the requirements. A variety of protocols and guidelines are available in various texts and documents. Many of the guidelines are general and more appropriate for assays in chemistry sections of the laboratory but are applied in principle to molecular assays. This review presents information that laboratories may consider in their efforts to meet regulatory requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Implementation of mNGS in the clinical laboratory is a complex endeavour that requires customization of research protocols using a quality management approach consistent with regulatory standards90.”
From Clinical metagenomics (2019) · cites this paper as [90]
In the citing paper
“Clinical laboratories are highly regulated, and general laboratory and testing requirements apply to all molecular diagnostic assays reported for patient care90.”
From Clinical metagenomics (2019) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii
Klee, S. R., Tyczka, J., Ellerbrok, H., Franz, T., Linke, S., Baljer, G., & Appel, B. (2006) · BMC Microbiology · doi:10.1186/1471-2180-6-2 · Cited by 323
Saah, A. J., & Hoover, D. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-1-199701010-00026 · Cited by 269
Recommended Principles and Practices for Validating Clinical Molecular Pathology Tests
Jennings, L., Van Deerlin, V. M., & Gulley, M. L. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.5.743 · Cited by 250
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Evaluating diagnostic tests with imperfect standards
Valenstein, P. N. (1990) · American Journal of Clinical Pathology · doi:10.1093/ajcp/93.2.252 · Cited by 220 · cited 2×
“nate methods are used in trueness experiments (73).”
Method comparison and bias estimation using patient samples
Guideline, N. T. (1993) · Medical Entomology and Zoology · Cited by 173
Optimized Real-Time Quantitative PCR Measurement of Male Fetal DNA in Maternal Plasma
Zimmermann, B., El-Sheikhah, A., Nicolaides, K., Holzgreve, W., & Hahn, S. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051235 · Cited by 165
Garson, J. A., Grant, P. R., Ayliffe, U., Ferns, R. B., & Tedder, R. S. (2005) · Journal of Virological Methods · doi:10.1016/j.jviromet.2005.03.001 · Cited by 158
Olson, V. A., Laue, T., Laker, M. T., Babkin, I. V., Drosten, C., Shchelkunov, S. N., Niedrig, M., Damon, I. K., & Meyer, H. E. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1940-1946.2004 · Cited by 156
Djakovic-Svajcer, K. (2002) · Medicinski pregled · doi:10.2298/mpns0202005d · Cited by 154
Necessary Sample Size for Method Comparison Studies Based on Regression Analysis
Línnet, K. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.6.882 · Cited by 147
Virus Detection and Monitoring of Viral Load in Crimean-Congo Hemorrhagic Fever Virus Patients
Wölfel, R., Paweska, J. T., Petersen, N., Grobbelaar, A. A., Leman, P. A., Hewson, R., Georges-Courbot, M. C., Papa, A., Günther, S., & Drosten, C. (2007) · Emerging infectious diseases · doi:10.3201/eid1307.070068 · Cited by 136
Cai, T., Lou, G., Yang, J., Xu, D., & Meng, Z.-H. (2008) · Journal of Clinical Virology · doi:10.1016/j.jcv.2007.11.025 · Cited by 108
Drosten, C., Panning, M., Drexler, J. F., Hänsel, F., Pedroso, C., Yeats, J., de Souza Luna, L. K., Samuel, M., Liedigk, B., Lippert, U., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.066498 · Cited by 97
Drosten, C., Seifried, E., & Roth, W. K. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.12.4302-4308.2001 · Cited by 88
Real-Time PCR Detection of Parapoxvirus DNA,
Nitsche, A., Büttner, M., Hartnack, S., Pauli, G., & Meyer, H. E. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.060335 · Cited by 83
Real-time PCR system targeting a chromosomal marker specific for Bacillus anthracis
Antwerpen, M. H., Zimmermann, P., Bewley, K. R., Frangoulidis, D., & Meyer, H. (2008) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2008.06.001 · Cited by 81
Störmer, M., Kleesiek, K., & Dreier, J. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.070987 · Cited by 75
The use of mimics as internal standards to avoid false negatives in diagnostic PCR
Ballagi‐Pordány, A., & Bélak, S. (1996) · Molecular and Cellular Probes · doi:10.1006/mcpr.1996.0022 · Cited by 72
An invasive cleavage assay for direct quantitation of specific RNAs
Eis, P. S., Olson, M. C., Takova, T., Curtis, M. L., Olson, S. M., Vener, T. I., Ip, H. S., Vedvik, K. L., Bartholomay, C. T., Allawi, H. T., et al. (2001) · Nature Biotechnology · doi:10.1038/90290 · Cited by 66
Real-Time PCR Assay for Detection and Quantification of Hepatitis B Virus Genotypes A to G
Welzel, T. M., Miley, W., Parks, T. L., Goedert, J. J., Whitby, D., & Ortiz‐Conde, B. A. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.00024-06 · Cited by 60
Panning, M., Kilwinski, J., Greiner-Fischer, S., Peters, M. C., Kramme, S., Frangoulidis, D., Meyer, H., Henning, K., & Drosten, C. (2008) · BMC Microbiology · doi:10.1186/1471-2180-8-77 · Cited by 59
Molecular Pathology in Clinical Practice
Leonard, D. G. B., Kaul, K. L., Deerlin, V. M., Caliendo, A. M., & Bagg, A. (2007) · Springer eBooks · doi:10.1007/978-0-387-33227-7 · Cited by 52
Mahony, J. B., Petrich, A. K., Louie, L., Song, X., Chong, S., Smieja, M., Chernesky, M., Loeb, M. B., & Richardson, S. E. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.4.1471-1476.2004 · Cited by 51
Enhanced Reverse Transcription-PCR Assay for Detection of Norovirus Genogroup I
Dreier, J., Störmer, M., Mäde, D., Burkhardt, S., & Kleesiek, K. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.00443-06 · Cited by 45
Assessment of bias with emphasis on method comparison.
Johnson, R. (2008) · PubMed Central · Cited by 43
Selection and Analytical Evaluations of Methods-With Statistical Techniques
Línnet, K., & Boyd, J. C. (2006) · Research at the University of Copenhagen (University of Copenhagen) · Cited by 43
Kocjan, B. J., Seme, K., & Poljak, M. (2008) · Journal of Virological Methods · doi:10.1016/j.jviromet.2008.07.014 · Cited by 41
Detection and Differentiation of Bordetella spp. by Real-Time PCR
Koidl, C., Bozic, M., Burmeister, A., Heß, M., Marth, E., & Kessler, H. H. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.01303-06 · Cited by 39
Development of a multiple internal control for clinical diagnostic real-time amplification assays
Maaroufi, Y., Bruyne, J.-M. D., Duchateau, V., Scheen, R., & Crokaert, F. (2006) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2006.00125.x · Cited by 29
Real-time PCR assay for the detection of tanapox virus and yaba-like disease virus
Zimmermann, P., Thordsen, I., Frangoulidis, D., & Meyer, H. E. (2005) · Journal of Virological Methods · doi:10.1016/j.jviromet.2005.06.015 · Cited by 26
Verification and validation of multiplex nucleic acid assays
Wilson, J. A. (2008) · Cited by 26
Huawe, Z. (2007) · Laboratory Medicine · Cited by 22
Real-time PCR in clinical microbiology: verification, validation, and contamination control
Sloan, L. M. (2007) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2007.05.002 · Cited by 21
Valle, L., Amicizia, D., Bacilieri, S., Banfi, F., Riente, R., Durando, P., Sticchi, L., Gasparini, R., Esposito, C., Icardi, G., et al. (2006) · Journal of preventive medicine and hygiene · doi:10.15167/2421-4248/jpmh2006.47.4.66 · Cited by 21
Müller, J., Eis‐Hübinger, A. M., Däumer, M., Kaiser, R., Rox, J. M., Gürtler, L. G., Hanfland, P., & Pötzsch, B. (2007) · Journal of Virological Methods · doi:10.1016/j.jviromet.2007.01.013 · Cited by 19
Tedder, R. S., Ayliffe, U., Preiser, W., Brink, N. S., Grant, P. R., Peggs, K. S., Mackinnon, S., Kreig‐Schneider, F., Kirk, S., & Garson, J. A. (2002) · Journal of Medical Virology · doi:10.1002/jmv.2175 · Cited by 11
Bolotin, S., Lima, C. D., Choi, K.-W., Lombos, E., Burton, L., Mazzulli, T., & Drews, S. J. (2009) · PubMed · Cited by 10
Assays for viral sequences and their value in validation of viral elimination.
Saldanha, J. (1993) · PubMed · Cited by 8
Press, R. D. (1999) · Molecular Diagnosis · doi:10.1016/s1084-8592(99)80052-6 · Cited by 5
Viral Infections in Transplant Patients
Ferreira‐Gonzalez, A., & Caliendo, A. M. (2007) · Springer eBooks · doi:10.1007/978-0-387-33227-7_38 · Cited by 1
Research works printed but not linked: 16
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 21. Food and drugs 2010 vol. 8
- Title 42. Public health 2009 vol. 4
- Title 42. Public health 2009 vol. 4
- Title 42. Public health 2009 vol. 4
- Title 42. Public health 2009 vol. 4
- Title 42. Public health 2009 vol. 4
- Title 42. Public health 2009 vol. 4
- Section 1862(a) (1) exclusions from coverage and Medicare as a second payer now codified as Title 42 chapter 7 exclusions from coverage and Medicare as a second payer
- U.S. Department of Health and Human Services, Centers for Medicare and Medicaid Services. 1992. Clinical laboratory improvement amendments of 1988 (CLIA). Fed. Regist.57:7002-7186.
Cited by
Chiu, C. Y., & Miller, S. A. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0113-7 · Cited by 1,620
Histopathologic Diagnosis of Fungal Infections in the 21st Century
Guarner, J., & Brandt, M. E. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00053-10 · Cited by 1,007
“Laboratory-developed assays should be evaluated, verified, and validated in the laboratory before results are used for clinical diagnosis and patient care as indicated by federal regulations (25).”
BackgroundMethodReporting the limits of detection and quantification for environmental DNA assays
Klymus, K. E., Merkes, C. M., Allison, M. J., Goldberg, C. S., Helbing, C. C., Hunter, M. E., Jackson, C. A., Lance, R. F., Mangan, A. M., Monroe, E. M., et al. (2020) · Environmental DNA · doi:10.1002/edn3.29 · Cited by 582
“…of target analyte that can be detected with a defined level of con‐ fidence, with a 95% detection rate as the standard confidence level (Burd, 2010; Burns & Valdivia, 2007; Bustin et al., 2009; CLSI, 2012; Forootan et al., 2017; Furlan, Gleeson, Hardy, & Duncan, 2016; Wolk & Marlowe,…”
BackgroundRespiratory Syncytial Virus: Infection, Detection, and New Options for Prevention and Treatment
Griffiths, C., Drews, S. J., & Marchant, D. J. (2017) · Clinical Microbiology Reviews · doi:10.1128/cmr.00010-16 · Cited by 586
“Laboratory-developed assays also require significant validation and verification compared to FDA-or Health Canada-approved assays, and this is often not an insignificant investment (281).”
MethodddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens
Suo, T., Liu, X., Feng, J., Guo, M., Hu, W., Guo, D., Ullah, H., Yang, Y., Zhang, Q., Wang, X., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772678 · Cited by 450
Metadata
- Authors
- Burd, E. M.
- Affiliations
- Emory University Hospital (US)
- Corresponding author
- Burd, Eileen M.
- ORCID
- Burd, Eileen M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2010-07
- Volume
- 23
- Issue
- 3
- Pages
- 550-576
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- PMC
- PMC2901657
- OpenAlex
- W2096278562
- Cited by
- 550
- References
- 48
- Citations by year
- 2026: 30 · 2025: 43 · 2024: 36 · 2023: 42 · 2022: 42 · 2021: 41 · 2020: 38 · 2019: 36 · 2018: 39 · 2017: 37 · 2016: 44 · 2015: 35 · 2014: 32 · 2013: 21 · 2012: 18
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical Microbiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- laboratory-developed tests, molecular diagnosis, infectious diseases, assay validation, analytical sensitivity, analytical specificity, precision and accuracy, reference values, assay modification
- MeSH terms
- Communicable Diseases, Humans, Clinical Laboratory Techniques, Molecular Diagnostic Techniques, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.