Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
SUMMARY: Molecular technology has changed the way that clinical laboratories diagnose and manage many infectious diseases. Excellent sensitivity, specificity, and speed have made molecular assays an attractive alternative to culture or enzyme immunoassay methods. Many molecular assays are commercially available and FDA approved. Others, especially those that test for less common analytes, are often laboratory developed. Laboratories also often modify FDA-approved assays to include different extraction systems or additional specimen types. The Clinical Laboratory Improvement Amendments (CLIA) federal regulatory standards require clinical laboratories to establish and document their own performance specifications for laboratory-developed tests to ensure accurate and precise results prior to implementation of the test. The performance characteristics that must be established include accuracy, precision, reportable range, reference interval, analytical sensitivity, and analytical specificity. Clinical laboratories are challenged to understand the requirements and determine the types of experiments and analyses necessary to meet the requirements. A variety of protocols and guidelines are available in various texts and documents. Many of the guidelines are general and more appropriate for assays in chemistry sections of the laboratory but are applied in principle to molecular assays. This review presents information that laboratories may consider in their efforts to meet regulatory requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Implementation of mNGS in the clinical laboratory is a complex endeavour that requires customization of research protocols using a quality management approach consistent with regulatory standards90.”
From Clinical metagenomics (2019) · cites this paper as [90]
In the citing paper
“Clinical laboratories are highly regulated, and general laboratory and testing requirements apply to all molecular diagnostic assays reported for patient care90.”
From Clinical metagenomics (2019) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii
Klee, S. R., Tyczka, J., Ellerbrok, H., Franz, T., Linke, S., Baljer, G., & Appel, B. (2006) · BMC Microbiology · doi:10.1186/1471-2180-6-2 · Cited by 323
Saah, A. J., & Hoover, D. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-1-199701010-00026 · Cited by 269
Recommended Principles and Practices for Validating Clinical Molecular Pathology Tests
Jennings, L., Van Deerlin, V. M., & Gulley, M. L. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.5.743 · Cited by 250
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Research works printed but not linked: 16
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 56. Institutional review boards. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 864. Hematology and pathology devices, section 864.4020. Analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 807. Establishment registration and device listing for manufacturers and initial importers of devices. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.10. Labeling for in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.20. General requirements for manufacturers and producers of in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.30. Restrictions on the sale, distribution and use of analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 812. Investigational device exemptions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 820. Quality system regulation. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1455. Standard: clinical consultant qualifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.2. Definitions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1253. Standard: establishment and verification of performance specifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1255. Standard: calibration and calibration verification procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1256. Standard: control Procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1282. Standard: corrective actions. U.S. Government Printing Office, Washington, DC.
- Social Security Act. Section 1862(a) (1), exclusions from coverage and Medicare as a second payer, now codified as Title 42, chapter 7, exclusions from coverage and Medicare as a second payer, U.S. Code. U.S. House of Representatives, Washington, DC.
- U.S. Department of Health and Human Services, Centers for Medicare and Medicaid Services. 1992. Clinical laboratory improvement amendments of 1988 (CLIA). Fed. Regist. 57:7002-7186. [PubMed] [Google Scholar]
Cited by
Chiu, C. Y., & Miller, S. A. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0113-7 · Cited by 1,620
Histopathologic Diagnosis of Fungal Infections in the 21st Century
Guarner, J., & Brandt, M. E. (2011) · Clinical Microbiology Reviews · doi:10.1128/cmr.00053-10 · Cited by 1,007
“Laboratory-developed assays should be evaluated, verified, and validated in the laboratory before results are used for clinical diagnosis and patient care as indicated by federal regulations (25).”
BackgroundMethodReporting the limits of detection and quantification for environmental DNA assays
Klymus, K. E., Merkes, C. M., Allison, M. J., Goldberg, C. S., Helbing, C. C., Hunter, M. E., Jackson, C. A., Lance, R. F., Mangan, A. M., Monroe, E. M., et al. (2020) · Environmental DNA · doi:10.1002/edn3.29 · Cited by 582
“…of target analyte that can be detected with a defined level of con‐ fidence, with a 95% detection rate as the standard confidence level (Burd, 2010; Burns & Valdivia, 2007; Bustin et al., 2009; CLSI, 2012; Forootan et al., 2017; Furlan, Gleeson, Hardy, & Duncan, 2016; Wolk & Marlowe,…”
BackgroundRespiratory Syncytial Virus: Infection, Detection, and New Options for Prevention and Treatment
Griffiths, C., Drews, S. J., & Marchant, D. J. (2017) · Clinical Microbiology Reviews · doi:10.1128/cmr.00010-16 · Cited by 586
“Laboratory-developed assays also require significant validation and verification compared to FDA-or Health Canada-approved assays, and this is often not an insignificant investment (281).”
MethodddPCR: a more accurate tool for SARS-CoV-2 detection in low viral load specimens
Suo, T., Liu, X., Feng, J., Guo, M., Hu, W., Guo, D., Ullah, H., Yang, Y., Zhang, Q., Wang, X., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772678 · Cited by 450
Liu, J., Kabir, F., Manneh, J., Lertsethtakarn, P., Begum, S., Gratz, J., Becker, S. M., Operario, D. J., Taniuchi, M., Janaki, L., et al. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(14)70808-4 · Cited by 307
Emerging Technologies for the Clinical Microbiology Laboratory
Buchan, B. W., & Ledeboer, N. A. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00003-14 · Cited by 297
“For an excellent review of challenges and methods for validation of molecular diagnostic tests, the reader is directed to a review by Burd (3).”
MethodLAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community
Moehling, T. J., Choi, G., Dugan, L. C., Salit, M., & Meagher, R. J. (2021) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2021.1873769 · Cited by 286
Borchardt, M. A., Boehm, A. B., Salit, M., Spencer, S. K., Wigginton, K. R., & Noble, R. T. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c01767 · Cited by 254
Duffy, T., Cura, C. I., Ramirez, J. C., Abate, T., Cayo, N. M., Parrado, R., Bello, Z. D., Velazquez, E., Muñoz-Calderon, A., Juiz, N. A., et al. (2013) · PLoS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0002000 · Cited by 257
“Homologous extrinsic controls, as well as heterologous intrinsic and extrinsic controls have been proposed as IACs [30].”
BackgroundMethodInfluentialMicrobiological safety of the first clinical pig islet xenotransplantation trial in New Zealand
Wynyard, S., Nathu, D., Garkavenko, O., Denner, J., & Elliott, R. (2014) · Xenotransplantation · doi:10.1111/xen.12102 · Cited by 220
Exosome-Based Detection of EGFR T790M in Plasma from Non–Small Cell Lung Cancer Patients
Castellanos-Rizaldos, E., Grimm, D. G., Tadigotla, V., Hurley, J., Healy, J., Neal, P. L., Sher, M., Venkatesan, R., Karlovich, C., Raponi, M., et al. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-17-3369 · Cited by 213
“Analytical and clinical validation Analytical and clinical validation of the test was performed in a Clinical Laboratory Improvement Amendments (CLIA) certified laboratory, following CLSI EP7-A2 and published guidelines (30, 31).”
MethodWaggoner, J. J., Gresh, L., Mohamed-Hadley, A., Ballesteros, G., Davila, M. J. V., Tellez, Y., Sahoo, M. K., Balmaseda, A., Harris, E., & Pinsky, B. A. (2016) · Emerging Infectious Diseases · doi:10.3201/eid2207.160326 · Cited by 213
Comino, I., Fernández-Bañares, F., Esteve, M., Ortigosa, L., Castillejo, G., Fambuena, B., Ribes-Koninckx, C., Sierra, C., Rodríguez-Herrera, A., Salazar, J. C., et al. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2016.439 · Cited by 207
Ramírez, J. C., Cura, C. I., da Cruz Moreira, O., Lages-Silva, E., Juiz, N., Velázquez, E., Ramírez, J. D., Alberti, A., Pavia, P., Flores-Chávez, M. D., et al. (2015) · The Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2015.04.010 · Cited by 198
Finak, G., Frelinger, J., Jiang, W., Newell, E. W., Ramey, J., Davis, M. M., Kalams, S. A., De Rosa, S. C., & Gottardo, R. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003806 · Cited by 197
Molecular diagnostics in medical mycology
Wickes, B. L., & Wiederhold, N. P. (2018) · Nature Communications · doi:10.1038/s41467-018-07556-5 · Cited by 188
Charlton, C. L., Babady, E., Ginocchio, C. C., Hatchette, T. F., Jerris, R. C., Li, Y., Loeffelholz, M., McCarter, Y. S., Miller, M. B., Novak-Weekley, S., et al. (2018) · Clinical Microbiology Reviews · doi:10.1128/cmr.00042-18 · Cited by 188
“Many in-depth documents and reviews discussing the requirements of molecular assay validation have previously been published (218, 219); therefore, a detailed discussion will not be included in this article.”
BackgroundA comparison of SARS-CoV-2 wastewater concentration methods for environmental surveillance
Philo, S. E., Keim, E. K., Swanstrom, R., Ong, A. Q. W., Burnor, E. A., Kossik, A. L., Harrison, J. C., Demeke, B. A., Zhou, N. A., Beck, N. K., et al. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.144215 · Cited by 159
“The LOD was determined as the concentration below which less than 90% of replicates are detected as positive (Burd, 2010).”
BackgroundGuidance Document on Good In Vitro Method Practices (GIVIMP)
OECD (2018) · OECD Series on Testing and Assessment · doi:10.1787/9789264304796-en · Cited by 161
“(Burd, 2010[27]; EMA, 2011[5]; FDA, 2001[6]; Viswanathan et al., 2007[28]).”
Analytical comparisons of SARS-COV-2 detection by qRT-PCR and ddPCR with multiple primer/probe sets
Liu, X., Feng, J., Zhang, Q., Guo, D., Zhang, L., Suo, T., Hu, W., Guo, M., Wang, X., Huang, Z., et al. (2020) · Emerging Microbes & Infections · doi:10.1080/22221751.2020.1772679 · Cited by 158
“using universal methods with standard materials or lots of patients’ samples, which were not included in this study [9,10].”
MethodA practical guide to validation and verification of analytical methods in the clinical laboratory
Pum, J. K. W. (2019) · Advances in clinical chemistry · doi:10.1016/bs.acc.2019.01.006 · Cited by 221
Interpreting Quantitative Cytomegalovirus DNA Testing: Understanding the Laboratory Perspective
Kraft, C. S., Armstrong, W. S., & Caliendo, A. M. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cis212 · Cited by 156
Diagnostics based on nucleic acid sequence variant profiling: PCR, hybridization, and NGS approaches
Khodakov, D., Wang, C., & Zhang, D. Y. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.005 · Cited by 155
Forty Years of Molecular Diagnostics for Infectious Diseases
Schmitz, J. E., Stratton, C. W., Persing, D. H., & Tang, Y. (2022) · Journal of Clinical Microbiology · doi:10.1128/jcm.02446-21 · Cited by 194
“ratories to validate new laboratory developed tests (LDTs) that meet local needs (39).”
BackgroundFan, S., Zhao, M., Ding, L., Li, H., & Chen, S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.108 · Cited by 144
Laboratory Diagnosis of Pertussis
van der Zee, A., Schellekens, J. F. P., & Mooi, F. R. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00031-15 · Cited by 171
“An excellent guideline for validation of laboratory-developed molecular assays for infectious diseases was presented by Burd in 2010 (152), and the following validation parameters are recommended: a study of the reportable range or linearity of PCR amplification of serial dilutions and assessments of the lower limit o…”
BackgroundWaggoner, J. J., Abeynayake, J. I., Sahoo, M. K., Gresh, L., Téllez, Y., González, K., Ballesteros, G., Pierro, A. M., Gaibani, P., Guo, F. P., et al. (2013) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0002116 · Cited by 136
“The analytical evaluation of the DENV multiplex rRT-PCR was performed according to previously published recommendations [31].”
MethodThe use of next generation sequencing in the diagnosis and typing of respiratory infections
Thorburn, F., Bennett, S. E., Modha, S., Murdoch, D. R., Gunson, R. N., & Murcia, P. R. (2015) · Journal of Clinical Virology · doi:10.1016/j.jcv.2015.06.082 · Cited by 141
Liu, J., Kibiki, G. S., Maro, V. P., Maro, A., Kumburu, H., Swai, N., Taniuchi, M., Gratz, J. C., TONEY, D. M., Kang, G., et al. (2011) · Journal of Clinical Virology · doi:10.1016/j.jcv.2010.12.009 · Cited by 119
Grasso, P. (2002) · CRC Press eBooks · doi:10.3109/9780203361535-17 · Cited by 115
Molecular Methods and Platforms for Infectious Diseases Testing
Emmadi, R., Boonyaratanakornkit, J., Selvarangan, R., Shyamala, V., Zimmer, B. A., Williams, L. O., Bryant, B. R., Schutzbank, T. E., Schoonmaker, M. M., Amos, J. A., et al. (2011) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2011.05.011 · Cited by 113
Improved Analytical Sensitivity of Lateral Flow Assay using Sponge for HBV Nucleic Acid Detection
Tang, R., Yang, H., Gong, Y. M., Liu, Z., Li, X.-J., Wen, T., Qu, Z., Zhang, S., Mei, Q., & Xu, F. (2017) · Scientific Reports · doi:10.1038/s41598-017-01558-x · Cited by 97
Krolewiecki, A. J., Lifschitz, A., Moragas, M., Travacio, M., Valentini, R. N., Alonso, D. F., Solari, R., Tinelli, M., Cimino, R. O., Álvarez, L., et al. (2021) · EClinicalMedicine · doi:10.1016/j.eclinm.2021.100959 · Cited by 126
“All these parameters were determined according to the guidelines for in vitro quantitative diagnostic assays as were reported previously [14,15].”
Besuschio, S. A., Murcia, M. L., Benatar, A. F., Monnerat, S., Cruz, I., Picado, A., Curto, M. D. L. Á., Kubota, Y., Wehrendt, D. P., Pavia, P. X., et al. (2017) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0005779 · Cited by 105
Kozyreva, V. K., Truong, C.-L., Greninger, A. L., Crandall, J., Mukhopadhyay, R., & Chaturvedi, V. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00361-17 · Cited by 98
“Analytical specificity is referred to as the “ability of an assay to detect only the intended target and that quantification of the target is not affected by cross-reactivity from related or potentially interfering nucleic acids or specimenrelated conditions” (40).”
Direct Comparison of SARS-CoV-2 Analytical Limits of Detection across Seven Molecular Assays
Fung, B., Gopez, A., Servellita, V., Arevalo, S., Ho, C., Deucher, A., Thornborrow, E., Chiu, C. Y., & Miller, S. A. (2020) · Journal of Clinical Microbiology · doi:10.1128/jcm.01535-20 · Cited by 86
“58 Experimental LOD was determined as the lowest concentration tested with 95% detection, and Probit 59 LOD was determined using Probit analysis (4).”
MethodLiu, J., Gratz, J. C., Maro, A., Kumburu, H., Kibiki, G. S., Taniuchi, M., Howlader, A. M., Sobuz, S. U., Haque, R., Talukder, K. A., et al. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.05416-11 · Cited by 85
“The assay was validated as follows (7).”
Porrás, A., Yadón, Z. E., Altcheh, J., Britto, C., Chaves, G. C., Flévaud, L., Martins‐Filho, O. A., Ribeiro, I., Schijman, A. G., Shikanai‐Yasuda, M. A., et al. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003697 · Cited by 81
“Studies are under way to assess the negative predictive value of a PCR test to assess sterile cure (Isabela Ribeiro, personal communication).”
MethodInfluentialGade, L., Scheel, C. M., Pham, C. D., Lindsley, M. D., Iqbal, N. J., Cleveland, A. A., Whitney, A. M., Lockhart, S. R., Brandt, M. E., & Litvintseva, A. P. (2013) · Eukaryotic Cell · doi:10.1128/ec.00046-13 · Cited by 82
“The lowest concentration of DNA for which PCR product and DNA sequence could be obtained was considered the LOD of this method (28).”
BackgroundMethodMentasti, M., Fry, N. K., Afshar, B., Palepou-Foxley, C., Naik, F., & Harrison, T. G. (2012) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-011-1535-0 · Cited by 76
“The determination of the limit of detection (LOD) for a molecular assay is complex [5, 36].”
Prakash, A., Rezai, T., Krastins, B., Sarracino, D., Athanas, M., Russo, P., Ross, M. M., Zhang, H., Tian, Y., Kulasingam, V., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr100821m · Cited by 74
STROBE-metagenomics: a STROBE extension statement to guide the reporting of metagenomics studies
Bharucha, T., Oeser, C., Balloux, F., Brown, J. R., Carbo, E. C., Charlett, A., Chiu, C. Y., Claas, E. C. J., de Goffau, M. C., de Vries, J. J. C., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30199-7 · Cited by 95
Sharma, R., Singh, P., McCoy, R. C., Lenz, S. M., Donovan, K. M., Ochoa, M. T., Estrada‐García, I., Silva‐Miranda, M., Cruz, F. J., Balagon, M. F., et al. (2019) · Clinical Infectious Diseases · doi:10.1093/cid/ciz1121 · Cited by 74
Hasan, M. R., Mirza, F., Al-Hail, H., Sundararaju, S., Xaba, T., Iqbal, M., Alhussain, H., Yassine, H. M., Pérez‐López, A., & Tang, P. (2020) · PLoS ONE · doi:10.1371/journal.pone.0236564 · Cited by 72
“The limit of detection with 95% endpoint (C95) was determined by Probit regression analysis [15].”
MethodLeón, C. M., Muñoz, M., Hernández, C., Ayala, M. S., Flórez, C., Teherán, A. A., Cubides, J. R., & Ramírez, J. D. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.01907 · Cited by 79
Buchan, B. W., Hoff, J. S., Gmehlin, C. G., Perez, A., Faron, M. L., Munoz-Price, L. S., & Ledeboer, N. A. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa133 · Cited by 69
“A key characteristic of any diagnostic test is the analytical LoD, which is commonly defined as the concentration of analyte that will be detected in 95% of replicate tests.(10,11) This LoD can have greater or lesser impact on the clinical sensitivity of a test (defined as the number of infected patients detected by a…”
BackgroundZai, Y., Min, C., Wang, Z., Ding, Y., Zhao, H., Su, E., & He, N. (2022) · Lab on a Chip · doi:10.1039/d2lc00434h · Cited by 71
Popescu, F.-D., & Vieru, M. (2018) · World Journal of Methodology · doi:10.5662/wjm.v8.i3.17 · Cited by 67
Rosa, A. M. M., Louro, A. F., Martins, S. A. M., Inácio, J., Azevedo, A. M., & Prazeres, D. M. F. (2014) · Analytical Chemistry · doi:10.1021/ac5001288 · Cited by 76
Waggoner, J. J., Ballesteros, G., Gresh, L., Mohamed-Hadley, A. A., Téllez, Y., Sahoo, M. K., Abeynayake, J. I., Balmaseda, Á., Harris, E., & Pinsky, B. A. (2016) · Journal of Clinical Virology · doi:10.1016/j.jcv.2016.01.007 · Cited by 66
“Analytical characterization The analytical evaluation of the pan-DENV–CHIKV rRT-PCR was performed according to published recommendations [17] and as previously described [12,16].”
MethodTorlakovic, E., Cheung, C. C., D’Arrigo, C., Dietel, M., Francis, G. D., Gilks, C. B., Hall, J. A., Hornick, J. L., Ibrahim, M., Marchetti, A., et al. (2017) · Applied immunohistochemistry & molecular morphology · doi:10.1097/pai.0000000000000470 · Cited by 72
“In clinical IHC testing, similar to any other laboratory test, this evidence is obtained from evaluation and documentation of TPCs. 7,33,34 For TPCs relevant to IHC testing, see part 2 of the Evolution series.”
MethodAgnostic Sequencing for Detection of Viral Pathogens
Gauthier, N. P. G., Chorlton, S. D., Krajden, M., & Manges, A. R. (2023) · Clinical Microbiology Reviews · doi:10.1128/cmr.00119-22 · Cited by 82
Sinigalliano, C. D., Ervin, J., Werfhorst, L. C. V. D., Badgley, B. D., Ballesté, E., Bartkowiak, J., Boehm, A. B. B., Byappanahalli, M. N., Goodwin, K. D., Gourmelon, M., et al. (2013) · Water Research · doi:10.1016/j.watres.2013.02.059 · Cited by 63
Waggoner, J. J., Abeynayake, J. I., Sahoo, M. K., Gresh, L., Téllez, Y., González, K., Ballesteros, G., Balmaseda, Á., Karunaratne, K., Harris, E., et al. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.00548-13 · Cited by 60
“It has been advocated that ICs be used in settings where PCR inhibitors present a significant source of false-negative results, which may be particularly important in the performance of NAATs in countries where dengue is endemic (26, 32).”
BackgroundMethodMoreira, O. C., Yadón, Z. E., & Cupolillo, E. (2017) · Acta Tropica · doi:10.1016/j.actatropica.2017.09.020 · Cited by 60
Grand Challenges in Biosensors and Biomolecular Electronics
Liu, G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.707615 · Cited by 68
“Two hurdles exist for benchtop technologies walking out of the lab to the market (Burd, 2010): 1) the translation of laboratory-based technologies into clinical studies; 2) to translate clinical studies into medical practice.”
BackgroundRecommendations following a multi-laboratory comparison of microbial source tracking methods
Stewart, J. R., Boehm, A. B. B., Dubinsky, E. A., Fong, T.-T., Goodwin, K. D., Griffith, J. F., Noble, R. T., Shanks, O. C., VIJAYAVEL, K., & Weisberg, S. B. (2013) · Water Research · doi:10.1016/j.watres.2013.04.063 · Cited by 64
Stokdyk, J. P., Firnstahl, A. D., Spencer, S. K., Burch, T. R., & Borchardt, M. A. (2016) · Water Research · doi:10.1016/j.watres.2016.03.026 · Cited by 65
Li, L., Zhang, L., Montgomery, K. C., Jiang, L., Lyon, C. J., & Hu, Y. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100538 · Cited by 63
“Once a LDT is FDA approved, it is referred to as an in-vitro diagnostic device (IVD) and no longer falls under the CMS but is instead covered by the Food, Drug, and cosmetic Act, as amended by the Medical Device Amendment of 1976 [122].”
BackgroundHattab, S., Adrienne, H., Tariq, Z., Prado, I. V., Drobish, I. C., Lee, R., & Yee, R. (2024) · Antibiotics · doi:10.3390/antibiotics13080786 · Cited by 81
“A verification/validation of molecular methods typically include metrics such as sensitivity (or positive percent agreement [PPA]) and specificity (or negative percent agreement [NPA]) [52,53].”
MethodRiediger, I. N., Stoddard, R. A., Ribeiro, G. S., Nakatani, S. M., Moreira, S. D. R., Skraba, I., Biondo, A. W., dos Reis, M. G., Hoffmaster, A. R., Vinetz, J. M., et al. (2017) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0005940 · Cited by 60
Park, J. S., Cho, D.-H., Yang, J. H., Kim, M. Y., Shin, S. M., Kim, E. C., Park, S. S., & Seong, M. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2013.33.1.39 · Cited by 55
“Analytical sensitivity, specificity, and reproducibility The limit of detection was determined by probit analysis [16].”
MethodOECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-1-en · Cited by 54
Navigating the nuances of clinical sequence variant interpretation in Mendelian disease
Strande, N. T., Brnich, S. E., Roman, T. S., & Berg, J. S. (2018) · Genetics in Medicine · doi:10.1038/s41436-018-0100-y · Cited by 68
Kim, D., Sundling, K. E., Virk, R. K., Thrall, M. J., Alperstein, S. A., Bui, M. M., Chen, H., Donnelly, A. D., Lin, O., Liu, X., et al. (2023) · Journal of the American Society of Cytopathology · doi:10.1016/j.jasc.2023.11.006 · Cited by 53
How to assess the quality of your analytical method?
Topić, E., Nikolac, N., Panteghini, M., Theodorsson, E., Salvagno, G. L., Miler, M., Šimundić, A.-M., Infusino, I., Nordin, G., & Westgard, S. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0869 · Cited by 67
“The protocol for the verification can be defined by the laboratory and it may not be the same for every user [53].”
BackgroundTorlakovic, E., Cheung, C. C., D’Arrigo, C., Dietel, M., Francis, G. D., Gilks, C. B., Hall, J. A., Hornick, J. L., Ibrahim, M., Marchetti, A., et al. (2017) · Applied immunohistochemistry & molecular morphology · doi:10.1097/pai.0000000000000444 · Cited by 60
Nanobiosensors for detection of opioids: A review of latest advancements
Razlansari, M., Ulucan‐Karnak, F., Kahrizi, M., Mirinejad, S., Sargazi, S., Mishra, S., Rahdar, A., & Diez-Pascual, A. M. (2022) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2022.08.017 · Cited by 58
Parrado, R., Ramı́rez, J. C., de la Barra, A., Alonso‐Vega, C., Juiz, N. A., Ortiz, L., Illanes, D., Torrico, F., Gascón, J., Alves, F. P., et al. (2018) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01191-18 · Cited by 50
“cruzi CL-Brener DNA were included in every run, as recommended (23).”
BackgroundIFCC Interim Guidelines on Molecular Testing of SARS-CoV-2 Infection
Bohn, M. K., Mancini, N., Loh, T. P., Wang, C.-B., Grimmler, M., Gramegna, M., Yuen, K., Mueller, R., Koch, D. D., Sethi, S. K., et al. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1412 · Cited by 49
Biomarkers in the Diagnosis and Prognosis of Alzheimer’s Disease
Schaffer, C., Sarad, N., DeCrumpe, A., Goswami, D., Herrmann, S., Morales, J., Patel, P., & Osborne, J. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214559979 · Cited by 53
“Experiments must be designed to establish accuracy, precision, reportable range, reference interval, and analytical sensitivity/specificity of the proposed diagnostic device.(109,110) Although CLIA would require testing of the complete multiplex assay, this additional testing is likely to be minimal as the individual…”
MethodWaggoner, J. J., Balassiano, I. T., Abeynayake, J. I., Sahoo, M. K., Mohamed-Hadley, A. A., Liu, Y., Vital-Brazil, J. M., & Pinsky, B. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112356 · Cited by 56
“Analytical Characterization The pathogenic rtPCR was analytically characterized according to published recommendations [31].”
MethodCurrent Capabilities of Gut Microbiome–Based Diagnostics and the Promise of Clinical Application
Damhorst, G. L., Adelman, M. W., Woodworth, M. H., & Kraft, C. S. (2021) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa689 · Cited by 47
“This is especially crucial in a clinical diagnostic context, where reproducibility is only one aspect to having an accurate and precise test [41].”
BackgroundPinheiro, B. G., Hahn, R. C., Camargo, Z. P. D., & Rodrigues, A. M. (2020) · Journal of Fungi · doi:10.3390/jof6040293 · Cited by 49
Borysiak, M. D., Thompson, M. J., & Posner, J. D. (2016) · Lab on a Chip · doi:10.1039/c6lc00015k · Cited by 48
(2016) · ASM Press eBooks · doi:10.1128/9781555818814.ch11.1.1 · Cited by 47
Denkinger, C. M., Schumacher, S. G., Gilpin, C. M., Korobitsyn, A., Wells, W. A., Pai, M., Leeflang, M., Steingart, K. R., Bulterys, M. A., Schünemann, H. J., et al. (2019) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiz097 · Cited by 48
“Analytical validation refers to measuring accuracy, precision, and reproducibility of the test in contrived specimens or panels [18].”
BackgroundClinical metagenomics for infectious corneal ulcers: Rags to riches?
Ung, L., Bispo, P. J. M., Doan, T. A., Gelder, R. N. V., Gilmore, M. S., Lietman, T. M., Margolis, T. P., Zegans, M. E., Lee, C. S., & Chodosh, J. (2019) · The Ocular Surface · doi:10.1016/j.jtos.2019.10.007 · Cited by 47
Hopkins, M., Hau, S., Tiernan, C., Papadimitropoulos, A., Chawla, A., Beloukas, A. I., & Geretti, A. M. (2015) · Journal of Clinical Virology · doi:10.1016/j.jcv.2015.05.020 · Cited by 45
“Whilst a higher number of replicates is needed to give a definitive calculation of total imprecision for each platform, the wide limits of agreement observed in Bland–Altman analysis of Artus measurements supports the greater likelihood of analytical variation using this test [33].”
MethodQuality Assurance of RNA Expression Profiling in Clinical Laboratories
Tang, W., Hu, Z., Muallem, H., & Gulley, M. L. (2011) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2011.09.003 · Cited by 47
Biomarkers of Tobacco Smoke Exposure
Mattes, W. B., Yang, X., Orr, M. S., Richter, P., & Mendrick, D. L. (2014) · Advances in clinical chemistry · doi:10.1016/bs.acc.2014.09.001 · Cited by 53
Quality Assessment and Validation of High-Throughput Sequencing for Grapevine Virus Diagnostics
Soltani, N., Stevens, K., Klaassen, V. A., Hwang, M., Golino, D., & Rwahnih, M. A. (2021) · Viruses · doi:10.3390/v13061130 · Cited by 56
“Following a standard procedure for qualitative assays, the results from these comparisons are summarized in contingency tables (Table S3) from which agreement measures and kappa statistics were calculated [23].”
BackgroundMethodInfluentialNolte, F. S. (2015) · ASM Press eBooks · doi:10.1128/9781555817381.ch6 · Cited by 50
Shulman, L. M., Hindiyeh, M. Y., Muhsen, K., Cohen, D., Mendelson, E., & Sofer, D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0039455 · Cited by 43
“…include hemoglobin, immunoglobulins, bilirubin, triglycerides, complex polysaccharides, organic and phenolic compounds, glycogen, fats, and metabolic products especially those from pathological conditions, bacteria, vegetables, medications, anticoagulants, and drugs or alcohol [4,6,8,9,10,11].”
Chang, M., Gottlieb, G. S., Dragavon, J., Cherne, S., Kenney, D. L., Hawes, S. E., Smith, R. A., Kiviat, N. B., Sow, P. S., & Coombs, R. W. (2012) · Journal of Clinical Virology · doi:10.1016/j.jcv.2012.06.024 · Cited by 44
Zoysa, A. D., Efstratiou, A., Mann, G., Harrison, T. G., & Fry, N. K. (2016) · Journal of Medical Microbiology · doi:10.1099/jmm.0.000382 · Cited by 43
“The qPCR assay was validated according to local and other published guidelines for tests dependent on nucleic acid amplification and detection (Burd, 2010; Saunders et al., 2013).”
MethodCattet, M., Stenhouse, G. B., Janz, D. M., Kapronczai, L., Erlenbach, J. A., Jansen, H. T., Nelson, O. L., Robbins, C. T., & Boulanger, J. (2017) · Conservation Physiology · doi:10.1093/conphys/cox032 · Cited by 48
“…physiological indicator integrity (Macbeth et al., 2010; Yamanashi et al., 2016; Kroshko et al., 2017), and to establish performance specifications for the physiological indicator assay(s) such as the reportable range, analytical sensitivity, precision and accuracy (Lee et al., 2006; Burd, 2010).”
BackgroundQuantitative polymerase chain reaction in paucibacillary leprosy diagnosis: A follow-up study
Barbieri, R. R., Manta, F. S. D. N., Moreira, S. J. M., Sales, A. M., Nery, J. A. C., do Nascimento, L. P. R., Hacker, M. A., Pacheco, A. G., Machado, A. M., Sarno, E. N., et al. (2019) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0007147 · Cited by 43
Arshad, Z., Alturkistani, A., Brindley, D. A., Lam, C., Foley, K., & Meinert, E. (2019) · JMIR Public Health and Surveillance · doi:10.2196/14216 · Cited by 45
“Such methods have been found to be more sensitive and rapid and require less stringent conditions in terms of collection data [11,12].”
MethodMolecular and serological in-herd prevalence of Anaplasma marginale infection in Texas cattle
Hairgrove, T. B., Schroeder, M. E., Budke, C. M., RODGERS, S. J., Chung, C. J., Ueti, M. W., & Bounpheng, M. A. (2015) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2015.02.006 · Cited by 51
Multilaboratory assessment of metagenomic next-generation sequencing for unbiased microbe detection
Han, D., Diao, Z., Lai, H., Han, Y., Xie, J., Zhang, R., & Li, J. (2021) · Journal of Advanced Research · doi:10.1016/j.jare.2021.09.011 · Cited by 51
“tious diseases were not entirely suitable for this new technique, which enables unbiased detection of all potential pathogens in a single test [32].”
BackgroundDittrich, S., Castonguay-Vanier, J., Moore, C. E., Thongyoo, N., Newton, P. N., & Paris, D. H. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.02786-13 · Cited by 43
“The C95 endpoint is defined as the concentration of the analyte at which 95% of the evaluated samples test positive (30).”
Suggested guidelines for validation of real-time PCR assays in veterinary diagnostic laboratories
Toohey-Kurth, K. L., Reising, M. M., Tallmadge, R. L., Goodman, L. B., Bai, J., Bolin, S. R., Pedersen, J. C., Bounpheng, M. A., Pogranichniy, R. M., Christopher‐Hennings, J., et al. (2020) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638720960829 · Cited by 51
“Several methods can be used to determine the LOD, including 10-fold dilution series, 2-fold dilution series,(53,57) or probit analysis.(8,24,55) The simplest and most economical method to determine LOD for a rtPCR assay is by utilizing the dilution series that was generated during the analytical sensitivity determinat…”
BackgroundMethodInfluentialAssessing Plasmodium falciparum transmission in mosquito-feeding assays using quantitative PCR
Wang, C. Y. T., McCarthy, J. S., Stone, W. J., Bousema, T., Collins, K. A., & Bialasiewicz, S. (2018) · Malaria Journal · doi:10.1186/s12936-018-2382-6 · Cited by 48
Ismail, A. M., Sivakumar, J., Anantharam, R., Dayalan, S., Samuel, P., Fletcher, G. J., Gnanamony, M., & Abraham, P. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.00915-11 · Cited by 41
“In this evaluation, analytical specificity was not performed as it is required mainly for home-brewed assays (2).”
BackgroundChan, J. F., Yip, C. C., Tee, K., Zhu, Z., Tsang, J. O., Chik, K. K., Tsang, T. G., Chan, C. C., Poon, V. K., Sridhar, S., et al. (2017) · Tropical Medicine & International Health · doi:10.1111/tmi.12857 · Cited by 45
“LOD is the lowest actual concentration of an analyte in a specimen that can be consistently detected with precision under routine laboratory conditions and in a defined specimen type [33].”
BackgroundDiao, Z., Lai, H., Han, D., Yang, B., Zhang, R., & Li, J. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.03812-22 · Cited by 44
“The Clinical Laboratory Improvement Amendments required laboratories to fully validate the LDTs and established the performance characteristics before implementation in the clinical setting (5, 6).”
BackgroundMethodFernandes, A. G., Trindade, G. F., Yamamura, A. M. Y., Moreira, O. C., de Paula, V. S., Duarte, A. C., Britto, C., & de Lima, S. M. B. (2015) · Human Vaccines & Immunotherapeutics · doi:10.4161/21645515.2014.990854 · Cited by 40
“For instance, the state of Rio de Janeiro is considered an endemic area for dengue virus infection.19 Some authors emphasized the importance to evaluate the analytical specificity of the test, as also recommended by FDA.20,21 By our evaluation, no significant difference inferred by Pearson’s correlation coefficient (p…”
BackgroundInfluentialMoreira, O. C., Verly, T., Finamore-Araújo, P., Gomes, S. A. O., Lopes, C. M., de Sousa, D. M., Azevedo, L. R., da Mota, F. F., d’Avila-Levy, C. M., Mallet, J. R. D. S., et al. (2017) · Parasites & Vectors · doi:10.1186/s13071-017-2343-x · Cited by 40
“The LOD was calculated as the lowest parasitic load corresponding to ≥ 95% of PCR positive results, according to clinical and laboratory standard guidelines [25].”
Method
Metadata
- Authors
- Burd, E. M.
- Affiliations
- Emory University Hospital (US)
- Corresponding author
- Burd, Eileen M.
- ORCID
- Burd, Eileen M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2010-07
- Volume
- 23
- Issue
- 3
- Pages
- 550-576
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- PMC
- PMC2901657
- OpenAlex
- W2096278562
- Cited by
- 550
- References
- 48
- Citations by year
- 2026: 30 · 2025: 43 · 2024: 36 · 2023: 42 · 2022: 42 · 2021: 41 · 2020: 38 · 2019: 36 · 2018: 39 · 2017: 37 · 2016: 44 · 2015: 35 · 2014: 32 · 2013: 21 · 2012: 18
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical Microbiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- laboratory-developed tests, molecular diagnosis, infectious diseases, assay validation, analytical sensitivity, analytical specificity, precision and accuracy, reference values, assay modification
- MeSH terms
- Communicable Diseases, Humans, Clinical Laboratory Techniques, Molecular Diagnostic Techniques, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.