Purification and Characterization of PCR-Inhibitory Components in Blood Cells
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
In a recent study, immunoglobulin G in human plasma was identified as a major inhibitor of diagnostic PCR (W. Abu Al-Soud, L. J. Jönsson, and P. Rådström. J. Clin. Microbiol. 38:345–350, 2000). In this study, two major PCR inhibitors in human blood cells were purified using size exclusion and anion-exchange chromatographic procedures. Based on N-terminal amino acid sequencing and electrophoretic analysis of the purified polypeptides, hemoglobin and lactoferrin were identified as PCR-inhibitor components in erythrocytes and leukocytes, respectively. When different concentrations of hemoglobin or lactoferrin were added to PCR mixtures of 25 μl containing 10 different thermostable DNA polymerases and 1 ng of Listeria monocytogenes DNA as template DNA, Ampli Taq Gold,Pwo, and Ultma were inhibited in the presence of ≤1.3 μg of hemoglobin and ≤25 ng of lactoferrin, while rTth and Tli were found to resist inhibition of at least 100 μg of hemoglobin. In addition, the quantitative effects of seven low-molecular-mass inhibitors, present in blood samples or degradation products of hemoglobin, on real-time DNA synthesis of rTth using the LightCycler Instrument were investigated. A reaction system based on a single-stranded poly(dA) template with an oligo(dT) primer annealed to the 3′ end was used. It was found that the addition of 0.25 to 0.1 mg of bile per ml, 2.5 mM CaCl 2, 0.25 mM EDTA, 5 μM FeCl 3, and 0.01 IU of heparin per ml reduced the fluorescence to approximately 76, 70, 46, 17, and 51%, respectively. Finally, the effects of nine amplification facilitators were studied in the presence of hemoglobin and lactoferrin. Bovine serum albumin (BSA) was the most efficient amplification facilitator, so that the addition of 0.4% (wt/vol) BSA allowed Ampli Taq Gold to amplify DNA in the presence of 20 instead of 1 μg of hemoglobin and 500 instead of 5 ng of lactoferrin. Including 0.02% (wt/vol) gp32, a single-stranded-DNA binding protein, in the reaction mixture of Ampli Taq Gold was also found to reduce the inhibitory effects of hemoglobin and lactoferrin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Raza, H., John, A., & Nemmar, A. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350087 · Cited by 47,221
Chelex 100 as a Medium for Simple Extraction of DNA for PCR-Based Typing from Forensic Material
Walsh, P. S., Metzger, D. A., & Higuchi, R. (2013) · BioTechniques · doi:10.2144/000114018 · Cited by 5,830
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,654
Curry, S., Mandelkow, H., Brick, P., & Franks, N. (1998) · Nature Structural Biology · doi:10.1038/1869 · Cited by 1,377
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Genetic analysis of amplified DNA with immobilized sequence-specific oligonucleotide probes.
Saiki, R. K., Walsh, P. S., Levenson, C. H., & Erlich, H. A. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.16.6230 · Cited by 1,008
Relief of amplification inhibition in PCR with bovine serum albumin or T4 gene 32 protein
Kreader, C. A. (1996) · Applied and Environmental Microbiology · doi:10.1128/aem.62.3.1102-1106.1996 · Cited by 852
Cited by
PCR inhibitors - occurrence, properties and removal
Schrader, C., Schielke, A., Ellerbroek, L., & Johne, R. (2012) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2012.05384.x · Cited by 2,118
Aguero-Rosenfeld, M. E., Wang, G., Schwartz, I., & Wormser, G. P. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.3.484-509.2005 · Cited by 744
A fully integrated microfluidic genetic analysis system with sample-in–answer-out capability
Easley, C. J., Karlinsey, J. M., Bienvenue, J. M., Legendre, L. A., Roper, M. G., Feldman, S. H., Hughes, M. A., Hewlett, E. L., Merkel, T. J., Ferrance, J. P., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604663103 · Cited by 547
Long Noncoding RNAs in Patients With Acute Myocardial Infarction
Vausort, M., Wagner, D. R., & Devaux, Y. (2014) · Circulation Research · doi:10.1161/circresaha.115.303836 · Cited by 491
Poon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Laboratory Diagnostics of Botulism
Lindström, M., & Korkeala, H. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.2.298-314.2006 · Cited by 474
Pre-PCR Processing : Strategies to Generate PCR-Compatible Samples
Rådström, P., Knutsson, R., Wolffs, P., Lövenklev, M., & Löfström, C. (2004) · Molecular Biotechnology · doi:10.1385/mb:26:2:133 · Cited by 452
Methodological challenges in utilizing mi RNA s as circulating biomarkers
Moldovan, L., Batte, K. E., Trgovcich, J., Wisler, J., Marsh, C. B., & Piper, M. (2014) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.12236 · Cited by 436
“The importance of these factors also lies in the fact that haemoglobin and lactoferrin may be released in the process, and these have been demonstrated to inhibit subsequent qRT-PCR [107].”
BackgroundMethodPCR inhibition in qPCR, dPCR and MPS—mechanisms and solutions
Sidstedt, M., Rådström, P., & Hedman, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02490-2 · Cited by 397
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Hand-powered ultralow-cost paper centrifuge
Bhamla, M. S., Benson, B., Chai, C., Katsikis, G., Johri, A., & Prakash, M. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0009 · Cited by 305
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Devonshire, A. S., Whale, A. S., Gutteridge, A., Jones, G., Cowen, S., Foy, C. A., & Huggett, J. F. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7835-3 · Cited by 299
“Paper Machine” for Molecular Diagnostics
Connelly, J. T., Rolland, J. P., & Whitesides, G. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00411 · Cited by 289
Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-99 · Cited by 287
Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Kermekchiev, M. B., Kirilova, L. I., Vail, E. E., & Barnes, W. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkn1055 · Cited by 259
Queipo-Ortuño, M. I., De Dios Colmenero, J., Macias, M., Bravo, M. J., & Morata, P. (2008) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00270-07 · Cited by 255
Microbial diagnosis of bloodstream infection: towards molecular diagnosis directly from blood
Opota, O., Jaton, K., & Greub, G. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2015.02.005 · Cited by 249
New Concepts in Cancer Biomarkers: Circulating miRNAs in Liquid Biopsies
Larrea, E., Sole, C., Manterola, L., Goicoechea, I., Armesto, M., Arestin, M., Caffarel, M., Araujo, A., Araiz, M., Fernandez-Mercado, M., et al. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17050627 · Cited by 239
“In addition, the choice of anti-coagulant used in plasma collection can influence downstream detection technologies, such as qRT-PCR and heparin-coated tubes, should be avoided [447].”
BackgroundYin, K., Ding, X., Li, Z., Zhao, H., Cooper, K., & Liu, C. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01459 · Cited by 235
Nakayama, S., & Sintim, H. O. (2009) · Journal of the American Chemical Society · doi:10.1021/ja902951b · Cited by 204
Microfluidic platform towards point-of-care diagnostics in infectious diseases
Su, W., Gao, X., Jiang, L., & Qin, J. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.12.041 · Cited by 196
Kaarj, K., Akarapipad, P., & Yoon, J.-Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-30797-9 · Cited by 184
Bisseux, M., Colombet, J., Mirand, A., Roque-Afonso, A.-M., Abravanel, F., Izopet, J., Archimbaud, C., Peigue-Lafeuille, H., Debroas, D., Bailly, J.-L., et al. (2018) · Eurosurveillance · doi:10.2807/1560-7917.es.2018.23.7.17-00237 · Cited by 169
“This was unexpected in treated water but could be explained by the use of ferric chloride, a PCR inhibitor [24], during the wastewater treatment process implemented in this WWTP, only the PeV assay was affected.”
BackgroundFenollar, F., Fournier, P. E., & Raoult, D. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.11.4919-4924.2004 · Cited by 166
“Due to the presence of inhibitors in blood (1, 3 ) and to the small amount of bacterial DNA present in serum, typical PCR assays are not efficient.”
BackgroundOvercoming Inhibition in Real-Time Diagnostic PCR
Hedman, J., & Rådström, P. (2013) · Methods in Molecular Biology · doi:10.1007/978-1-60327-353-4_2 · Cited by 164
Advances in Real‐Time PCR: Application to Clinical Laboratory Diagnostics
(2005) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(05)40006-2 · Cited by 164
“These polymerases have diVerent resistance to PCR‐inhibitory substances and they exhibit diVerent performance depending on sample type [14, 82, 83].”
BackgroundThe importance of a multifaceted approach to characterizing the microbial flora of chronic wounds
Han, A., Zenilman, J. M., Melendez, J. H., Shirtliff, M. E., Agostinho, A., James, G., Stewart, P. S., Mongodin, E. F., Rao, D., Rickard, A. H., et al. (2011) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2011.00720.x · Cited by 163
“A second possibility could be the presence of high levels of blood in the wound samples, resulting in significant amounts of PCR inhibitors such as hemoglobin in the extracted DNA.(26) Sequencing data of 45 chronic wound samples (which combined data from 15 samples in this series and 30 additional samples in a previou…”
BackgroundResultInfluentialTzanakaki, G., Tsopanomichalou, M., Kesanopoulos, K., Matzourani, R., Sioumala, M., Tabaki, A., & Kremastinou, J. (2005) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2005.01109.x · Cited by 106
Metadata
- Authors
- Al-Soud, W. A., & Rådström, P.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2001-02
- Volume
- 39
- Issue
- 2
- Pages
- 485-493
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2095989309
- Cited by
- 944
- References
- 42
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.