Evaluation of the VITEK 2 System for Identification and Antimicrobial Susceptibility Testing of Medically Relevant Gram-Positive Cocci
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A study was conducted to evaluate the new VITEK 2 system (bioMérieux) for identification and antibiotic susceptibility testing of gram-positive cocci. Clinical isolates of Staphylococcus aureus ( n = 100), coagulase-negative staphylococci (CNS) ( n = 100), Enterococcus spp. ( n = 89), Streptococcus agalactiae ( n = 29), and Streptococcus pneumoniae ( n = 66) were examined with the ID-GPC identification card and with the AST-P515 (for staphylococci), AST-P516 (for enterococci and S. agalactiae ) and AST-P506 (for pneumococci) susceptibility cards. The identification comparison methods were the API Staph for staphylococci and the API 20 Strep for streptococci and enterococci; for antimicrobial susceptibility testing, the agar dilution method according to the procedure of the National Committee for Clinical Laboratory Standards (NCCLS) was used. The VITEK 2 system correctly identified to the species level (only one choice or after simple supplementary tests) 99% of S. aureus , 96.5% of S. agalactiae , 96.9% of S. pneumoniae , 92.7% of Enterococcus faecalis , 91.3% of Staphylococcus haemolyticus , and 88% of Staphylococcus epidermidis but was least able to identify Enterococcus faecium (71.4% correct). More than 90% of gram-positive cocci were identified within 3 h. According to the NCCLS breakpoints, antimicrobial susceptibility testing with the VITEK 2 system gave 96% correct category agreement, 0.82% very major errors, 0.17% major errors, and 2.7% minor errors. Antimicrobial susceptibility testing showed category agreement from 94 to 100% for S. aureus , from 90 to 100% for CNS, from 91 to 100% for enterococci, from 96 to 100% for S. agalactiae , and from 91 to 100% for S. pneumoniae . Microorganism-antibiotic combinations that gave very major errors were CNS-erythromycin, CNS-oxacillin, enterococci-teicoplanin, and enterococci-high-concentration gentamicin. Major errors were observed for CNS-oxacillin and S. agalactiae- tetracycline combinations. In conclusion the results of this study indicate that the VITEK 2 system represents an accurate and acceptable means for performing identification and antibiotic susceptibility tests with medically relevant gram-positive cocci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods for dilution antimicrobial susceptibility tests for bacteria that grow aerobically
Ferraro, M. J. (2000) · Cited by 16,875
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
Manual of Clinical Microbiology.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-6-939_2 · Cited by 14,411
The life and times of the Enterococcus
Murray, B. E. (1990) · Clinical Microbiology Reviews · doi:10.1128/cmr.3.1.46 · Cited by 1,908
Manual of Clinical Microbiology, 7th ed.
Balows, A. (2000) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/s0732-8893(99)00102-9 · Cited by 1,613
Dutka-Malen, S., Evers, S., & Courvalin, P. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.1.24-27.1995 · Cited by 1,403
Diagnostic molecular microbiology : principles and applications
Persing, D. H. (1993) · ASM Press eBooks · Cited by 1,311
Arthur, M., Molinas, C., Depardieu, F., & Courvalin, P. (1993) · Journal of Bacteriology · doi:10.1128/jb.175.1.117-127.1993 · Cited by 603
Barenfanger, J., Drake, C., & Kacich, G. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.5.1415-1418.1999 · Cited by 370
Laboratory, clinical, and epidemiological aspects of coagulase-negative staphylococci
Pfaller, M. A., & Herwaldt, L. A. (1988) · Clinical Microbiology Reviews · doi:10.1128/cmr.1.3.281 · Cited by 351
Current perspectives on glycopeptide resistance
Woodford, N., Johnson, A. P., Morrison, D., & Speller, D. C. (1995) · Clinical Microbiology Reviews · doi:10.1128/cmr.8.4.585 · Cited by 298
Evaluation of the VITEK 2 System for Rapid Identification of Medically Relevant Gram-Negative Rods
Funke, G., Monnet, D., deBernardis, C., von Graevenitz, A., & Freney, J. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.1948-1952.1998 · Cited by 196
Automated systems for identification of microorganisms
Stager, C. E., & Davis, J. R. (1992) · Clinical Microbiology Reviews · doi:10.1128/cmr.5.3.302 · Cited by 161
Predari, S. C., Ligozzi, M., & Fontana, R. (1991) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.35.12.2568 · Cited by 116
Self-citation
Cited by
Pseudomonas aeruginosa Biofilms
Thi, M. T. T., Wibowo, D., & Rehm, B. H. A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21228671 · Cited by 911
Advances in Chemical and Biological Methods to Identify Microorganisms—From Past to Present
Franco-Duarte, R., Černáková, L., Kadam, S., S. Kaushik, K., Salehi, B., Bevilacqua, A., Corbo, M. R., Antolak, H., Dybka-Stępień, K., Leszczewicz, M., et al. (2019) · Microorganisms · doi:10.3390/microorganisms7050130 · Cited by 565
Antimicrobial Susceptibility Testing: A Comprehensive Review of Currently Used Methods
Gajic, I., Kabic, J., Kekic, D., Jovicevic, M., Milenkovic, M., Mitic Culafic, D., Trudic, A., Ranin, L., & Opavski, N. (2022) · Antibiotics · doi:10.3390/antibiotics11040427 · Cited by 557
Fiebelkorn, K. R., Crawford, S. A., McElmeel, M. L., & Jorgensen, J. H. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.10.4740-4744.2003 · Cited by 454
Brown, D. F. J., Edwards, D. I., Hawkey, P. M., Morrison, D., Ridgway, G. L., Towner, K. J., & Wren, M. W. D. (2005) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dki372 · Cited by 410
Metadata
- Authors
- Ligozzi, M., Bernini, C., Bonora, M. G., de Fatima, M., Zuliani, J., & Fontana, R.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2002-05
- Volume
- 40
- Issue
- 5
- Pages
- 1681-1686
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2096784236
- Cited by
- 265
- References
- 14
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.