Optical Properties of the Subcutaneous Adipose Tissue in the Spectral Range 400–2500 nm
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The optical characteristics of subcutaneous adipose tissue are studied in the wavelength range 400–2500 nm. The experiments are conducted in vitro using a Cary 2415 spectrophotometer. Based on the measured diffuse reflectance and total transmittance spectra, the spectra of the absorption and transport scattering coefficients are calculated in terms of the inverse adding-doubling method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Dobson, P. J. (1984) · Physics Bulletin · doi:10.1088/0031-9112/35/3/025 · Cited by 2,539
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Cited by
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Self-citationRare-earth-doped biological composites as in vivo shortwave infrared reporters
Naczynski, D. J., Tan, M. C., Zevon, M., Wall, B., Kohl, J., Kulesa, A., Chen, S., Roth, C. M., Riman, R. E., & Moghe, P. V. (2013) · Nature Communications · doi:10.1038/ncomms3199 · Cited by 759
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
Exploration of Near-Infrared Organic Photodetectors
Li, Q., Guo, Y., & Liu, Y. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b00966 · Cited by 328
Golovynskyi, S., Golovynska, I., Stepanova, L. I., Datsenko, O. I., Liu, L., Qu, J., & Ohulchanskyy, T. Y. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800141 · Cited by 209
Optogenetic defibrillation terminates ventricular arrhythmia in mouse hearts and human simulations
Bruegmann, T., Boyle, P. M., Vogt, C. C., Karathanos, T. V., Arevalo, H. J., Fleischmann, B. K., Trayanova, N. A., & Sasse, P. (2016) · Journal of Clinical Investigation · doi:10.1172/jci88950 · Cited by 182
Chen, A. I., Balter, M. L., Chen, M. I., Gross, D., Alam, S. K., Maguire, T. J., & Yarmush, M. L. (2016) · Medical Physics · doi:10.1118/1.4951729 · Cited by 158
Setchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2023) · Biomedical Optics Express · doi:10.1364/boe.493588 · Cited by 49
Metadata
- Authors
- Bashkatov, A. N.
- Venue
- Optics and Spectroscopy
- Publisher
- Pleiades Publishing Ltd
- Published
- 2005
- Volume
- 99
- Issue
- 5
- Pages
- 836
- ISSN
- 0030-400X (ISSN-L)
- OpenAlex
- W2099855983
- Cited by
- 142
- References
- 4
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.