Understanding and preventing wrong-patient electronic orders: a randomized controlled trial
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate systems for estimating and preventing wrong-patient electronic orders in computerized physician order entry systems with a two-phase study. MATERIALS AND METHODS: In phase 1, from May to August 2010, the effectiveness of a 'retract-and-reorder' measurement tool was assessed that identified orders placed on a patient, promptly retracted, and then reordered by the same provider on a different patient as a marker for wrong-patient electronic orders. This tool was then used to estimate the frequency of wrong-patient electronic orders in four hospitals in 2009. In phase 2, from December 2010 to June 2011, a three-armed randomized controlled trial was conducted to evaluate the efficacy of two distinct interventions aimed at preventing these errors by reverifying patient identification: an 'ID-verify alert', and an 'ID-reentry function'. RESULTS: The retract-and-reorder measurement tool effectively identified 170 of 223 events as wrong-patient electronic orders, resulting in a positive predictive value of 76.2% (95% CI 70.6% to 81.9%). Using this tool it was estimated that 5246 electronic orders were placed on wrong patients in 2009. In phase 2, 901 776 ordering sessions among 4028 providers were examined. Compared with control, the ID-verify alert reduced the odds of a retract-and-reorder event (OR 0.84, 95% CI 0.72 to 0.98), but the ID-reentry function reduced the odds by a larger magnitude (OR 0.60, 95% CI 0.50 to 0.71). DISCUSSION AND CONCLUSION: Wrong-patient electronic orders occur frequently with computerized provider order entry systems, and electronic interventions can reduce the risk of these errors occurring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Classen, D. C., Resar, R., Griffin, F., Federico, F., Frankel, T., Kimmel, N., Whittington, J. C., Frankel, A., Seger, A., & James, B. C. (2011) · Health Affairs · doi:10.1377/hlthaff.2011.0190 · Cited by 1,027
Types of Unintended Consequences Related to Computerized Provider Order Entry
Campbell, E. M., Sittig, D. F., Ash, J. S., Guappone, K. P., & Dykstra, R. H. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2042 · Cited by 823
Harrison, M. I., Koppel, R., & Bar-Lev, S. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2384 · Cited by 691
Health IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
A framework for analyzing the cognitive complexity of computer-assisted clinical ordering
Horsky, J., Kaufman, D. R., Oppenheim, M. I., & Patel, V. L. (2003) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00062-5 · Cited by 137
Kaushal, R., Shojania, K. G., & Bates, D. W. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.12.1409 · Cited by 30
Cited by
The effects of on-screen, point of care computer reminders on processes and outcomes of care
Shojania, K. G., Jennings, A., Ramsay, C. R., Grimshaw, J. M., Kwan, J. L., & Lo, L. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001096.pub2 · Cited by 466
Electronic health records and national patient-safety goals
Sittig, D. F., & Singh, H. (2012) · New England Journal of Medicine · doi:10.1056/nejmsb1205420 · Cited by 204
Singh, H., & Sittig, D. F. (2016) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004486 · Cited by 167
Reducing medication errors for adults in hospital settings
Ciapponi, A., Fernandez Nievas, S. E., Seijo, M., Rodríguez, M. B., Vietto, V., García-Perdomo, H. A., Virgilio, S., Fajreldines, A. V., Tost, J., Rose, C. J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009985.pub2 · Cited by 105
The unintended consequences of health information technology revisited
Ash, J., Berg, M., & Coiera, E. (2016) · Yearbook of Medical Informatics · doi:10.15265/iy-2016-014 · Cited by 101
“…process control models can identify errors in patient records, such as high rates of duplicate or missing orders, unexpected delays in orders, and special trigger rules can identify events that might be risky, such as the ordering and deletion of a medication order in rapid succession [36].”
Metadata
- Authors
- Adelman, J. S., Kalkut, G. E., Schechter, C. B., Weiss, J. M., Berger, M. A., Reissman, S. H., Cohen, H. W., Lorenzen, S. J., Burack, D. A., & Southern, W. N.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-03
- Volume
- 20
- Issue
- 2
- Pages
- 305-310
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2157459668
- Cited by
- 134
- References
- 9
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Understanding and preventing wrong-patient electronic orders: a randomized controlled trial. https://app.cochat.ai/papers/10.1136/amiajnl-2012-001055
- The paper
- Adelman, J. S., Kalkut, G. E., Schechter, C. B., Weiss, J. M., Berger, M. A., Reissman, S. H., Cohen, H. W., Lorenzen, S. J., Burack, D. A., & Southern, W. N. (2013). Understanding and preventing wrong-patient electronic orders: a randomized controlled trial. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2012-001055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.