Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 276

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study

Open access
Bongartz, Tim, Glazebrook, Katrina N, Kavros, Steven J, Murthy, Naveen S, Merry, Stephen P, Franz, Walter B, Michet, Clement J, Veetil, Barath M Akkara, Davis, John M, Mason, Thomas G, Warrington, Kenneth J, Ytterberg, Steven R, Matteson, Eric L, Crowson, Cynthia S, Leng, Shuai, McCollough, Cynthia H·2015·Annals of the Rheumatic Diseases

Abstract

OBJECTIVES: To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). METHODS: Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. RESULTS: The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). CONCLUSIONS: DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/annrheumdis-2013-205095

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 276

Metadata

Authors
Bongartz, T., Glazebrook, K. N., Kavros, S. J., Murthy, N. S., Merry, S. P., Franz, W. B., Michet, C. J., Veetil, B. M. A., Davis, J. M., Mason, T. G., Warrington, K. J., Ytterberg, S. R., Matteson, E. L., Crowson, C. S., Leng, S., & McCollough, C. H.
Venue
Annals of the Rheumatic Diseases
Publisher
Elsevier BV
Published
2015-06
Volume
74
Issue
6
Pages
1072-1077
ISSN
0003-4967 (ISSN-L)
OpenAlex
W2008245966
Cited by
276
References
15
FWCI
16.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. https://app.cochat.ai/papers/10.1136/annrheumdis-2013-205095
The paper
Bongartz, T., Glazebrook, K. N., Kavros, S. J., Murthy, N. S., Merry, S. P., Franz, W. B., Michet, C. J., Veetil, B. M. A., Davis, J. M., Mason, T. G., Warrington, K. J., Ytterberg, S. R., Matteson, E. L., Crowson, C. S., Leng, S., & McCollough, C. H. (2015). Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Annals of the Rheumatic Diseases. https://doi.org/10.1136/annrheumdis-2013-205095

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.