The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task
Open accessAbstract
BACKGROUND/AIMS: To determine to what extent subjects implanted with the Argus II retinal prosthesis can improve performance compared with residual native vision in a spatial-motor task. METHODS: High-contrast square stimuli (5.85 cm sides) were displayed in random locations on a 19″ (48.3 cm) touch screen monitor located 12″ (30.5 cm) in front of the subject. Subjects were instructed to locate and touch the square centre with the system on and then off (40 trials each). The coordinates of the square centre and location touched were recorded. RESULTS: Ninety-six percent (26/27) of subjects showed a significant improvement in accuracy and 93% (25/27) show a significant improvement in repeatability with the system on compared with off (p<0.05, Student t test). A group of five subjects that had both accuracy and repeatability values <250 pixels (7.4 cm) with the system off (ie, using only their residual vision) was significantly more accurate and repeatable than the remainder of the cohort (p<0.01). Of this group, four subjects showed a significant improvement in both accuracy and repeatability with the system on. CONCLUSION: In a study on the largest cohort of visual prosthesis recipients to date, we found that artificial vision augments information from existing vision in a spatial-motor task. Clinical trials registry no NCT00407602.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their performance also improved for object localization and motion discrimination tasks (Ahuja et al. 2011; Barry, Dagnelie, and Argus II Study Group 2012; Dorn et al. 2013; Dagnelie et al. 2017).”
From Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only (2022) · cites this paper as Ahuja et al. 2011
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationStone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 480
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 430
Perceptual thresholds and electrode impedance in three retinal prosthesis subjects
Mahadevappa, M., Weiland, J. D., Yanai, D., Fine, I., Greenberg, R. J., & Humayun, M. S. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848687 · Cited by 187
Self-citationVision Following Extended Congenital Blindness
Ostrovsky, Y., Andalman, A. S., & Sinha, P. (2006) · Psychological Science · doi:10.1111/j.1467-9280.2006.01827.x · Cited by 155
Feasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149
Self-citationAnIn VitroModel of a Retinal Prosthesis
Ahuja, A. K., Behrend, M. R., Kuroda, M., Humayun, M. S., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919126 · Cited by 111
Self-citation
Flagged first, then by citations
1 of the 19 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 101–106 of 106
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19
Paraskevoudi, N., & Pezaris, J. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-86996-4 · Cited by 16
Factors affecting two-point discrimination in argus II patients
Yücel, E. I., Sadeghi, R., Kartha, A., Montezuma, S. R., Dagnelie, G., Rokem, A., Boynton, G. M., Fine, I., & Beyeler, M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.901337 · Cited by 13
Self-citationHuman-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7615 · Cited by 15
Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only
Christie, B., Sadeghi, R., Kartha, A., Caspi, A., Tenore, F. V., Klatzky, R. L., Dagnelie, G., & Billings, S. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7326 · Cited by 10
Self-citationHuman-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Metadata
- Authors
- Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group
- Affiliations
- Second Sight Medical Products (US)
- Moorfields Eye Hospital (GB)
- Manchester Royal Eye Hospital (GB)
- Doheny Eye Institute (US)
- Corresponding author
- Ahuja, A. K.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2010-09-29
- Volume
- 95
- Issue
- 4
- Pages
- 539-543
- ISSN
- 0007-1161 (ISSN-L)
- PMC
- PMC3345188
- OpenAlex
- W2171460754
- Cited by
- 289
- References
- 19
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 7 · 2023: 8 · 2022: 14 · 2021: 15 · 2020: 17 · 2019: 17 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 20 · 2014: 27 · 2013: 27 · 2012: 26
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- UCL Discovery (University College London) (submittedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- National Eye Institute (R01EY012893, 5R01EY12893)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- Argus II retinal prosthesis, retinal prosthesis, visual prosthesis, visual augmentation, blind subjects, residual vision, visual acuity, task accuracy
- MeSH terms
- Adult, Aged, Aged, 80 and over, Blindness, Female, Humans, Male, Middle Aged, Motor Activity, Orientation, Prosthesis Design, Retina, Task Performance and Analysis, Touch, Treatment Outcome, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review