The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task
Open accessAbstract
BACKGROUND/AIMS: To determine to what extent subjects implanted with the Argus II retinal prosthesis can improve performance compared with residual native vision in a spatial-motor task. METHODS: High-contrast square stimuli (5.85 cm sides) were displayed in random locations on a 19″ (48.3 cm) touch screen monitor located 12″ (30.5 cm) in front of the subject. Subjects were instructed to locate and touch the square centre with the system on and then off (40 trials each). The coordinates of the square centre and location touched were recorded. RESULTS: Ninety-six percent (26/27) of subjects showed a significant improvement in accuracy and 93% (25/27) show a significant improvement in repeatability with the system on compared with off (p<0.05, Student t test). A group of five subjects that had both accuracy and repeatability values <250 pixels (7.4 cm) with the system off (ie, using only their residual vision) was significantly more accurate and repeatable than the remainder of the cohort (p<0.01). Of this group, four subjects showed a significant improvement in both accuracy and repeatability with the system on. CONCLUSION: In a study on the largest cohort of visual prosthesis recipients to date, we found that artificial vision augments information from existing vision in a spatial-motor task. Clinical trials registry no NCT00407602.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their performance also improved for object localization and motion discrimination tasks (Ahuja et al. 2011; Barry, Dagnelie, and Argus II Study Group 2012; Dorn et al. 2013; Dagnelie et al. 2017).”
From Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only (2022) · cites this paper as Ahuja et al. 2011
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Pattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 598
Self-citationStone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 480
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 430
Perceptual thresholds and electrode impedance in three retinal prosthesis subjects
Mahadevappa, M., Weiland, J. D., Yanai, D., Fine, I., Greenberg, R. J., & Humayun, M. S. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848687 · Cited by 187
Self-citationVision Following Extended Congenital Blindness
Ostrovsky, Y., Andalman, A. S., & Sinha, P. (2006) · Psychological Science · doi:10.1111/j.1467-9280.2006.01827.x · Cited by 155
Feasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149
Self-citationAnIn VitroModel of a Retinal Prosthesis
Ahuja, A. K., Behrend, M. R., Kuroda, M., Humayun, M. S., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919126 · Cited by 111
Self-citation
Flagged first, then by citations
1 of the 19 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Yuk, H., Lu, B., & Zhao, X. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,148
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G. A., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 460
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Self-citationFive-year safety and performance results from the argus II retinal prosthesis system clinical trial.
da Cruz, L., Dorn, J. D., Humayun, M. S., Dagnelie, G., Handa, J., Barale, P.-O., Sahel, J.-A., Stanga, P. E., Hafezi, F., Safran, A. B., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.06.049 · Cited by 359
Self-citationThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 327
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 298
Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind
Ho, A. C., Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Handa, J. T., Barale, P. O., Sahel, J., Stanga, P. E., Hafezi, F., et al. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.04.032 · Cited by 262
Self-citationPhotochemical Restoration of Visual Responses in Blind Mice
Polosukhina, A., Litt, J., Tochitsky, I., Nemargut, J. P., Sychev, Y., Kouchkovsky, I. D., Huang, T., Borges, K., Trauner, D. H., Gelder, R. N. V., et al. (2012) · Neuron · doi:10.1016/j.neuron.2012.05.022 · Cited by 238
Maidenbaum, S., Abboud, S., & Amedi, A. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.11.007 · Cited by 230
Advances in retinal prosthesis systems
Bloch, E., Luo, Y., & da Cruz, L. (2019) · Therapeutic Advances in Ophthalmology · doi:10.1177/2515841418817501 · Cited by 201
Retinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 196
Self-citationPersistent remodeling and neurodegeneration in late-stage retinal degeneration
Pfeiffer, R. L., Marc, R. E., & Jones, B. W. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.07.004 · Cited by 184
Microscopic magnetic stimulation of neural tissue
Bonmassar, G., Lee, S. W., Freeman, D. K., Polášek, M., Fried, S. I., & Gale, J. T. (2012) · Nature Communications · doi:10.1038/ncomms1914 · Cited by 180
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 169
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163
Self-citationPhotovoltaic retinal prosthesis: implant fabrication and performance
Wang, L., Mathieson, K., Kamins, T. I., Loudin, J., Galambos, L., Goetz, G. A., Sher, A., Mandel, Y., Huie, P., Lavinsky, D., et al. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046014 · Cited by 142
Kremláček, J., Kreegipuu, K., Tales, A., Astikainen, P., Põldver, N., Näätänen, R., & Stefanics, G. (2016) · Cortex · doi:10.1016/j.cortex.2016.03.017 · Cited by 148
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics
Niketeghad, S., & Pouratian, N. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0660-1 · Cited by 131
Eickenscheidt, M., Jenkner, M., Thewes, R., Fromherz, P., & Zeck, G. M. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00909.2011 · Cited by 118
Temporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113
Optogenetic approaches to vision restoration
Simunovic, M. P., Shen, W., Lin, J. Y., Protti, D. A., Lisowski, L., & Gillies, M. C. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.09.003 · Cited by 111
Chenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110
Regenerative and restorative medicine for eye disease
Gelder, R. N. V., Chiang, M. F., Dyer, M. A., Greenwell, T. N., Levin, L. A., Wong, R., & Svendsen, C. N. (2022) · Nature Medicine · doi:10.1038/s41591-022-01862-8 · Cited by 111
Retinitis Pigmentosa and Allied Disorders
Gregory-Evans, K., Pennesi, M. E., & Weleber, R. G. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-0737-9.00040-0 · Cited by 112
Cell-based therapeutic strategies for replacement and preservation in retinal degenerative diseases
Jones, M. K., Lü, B., Girman, S., & Wang, S. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.01.004 · Cited by 114
Differential responses to high-frequency electrical stimulation in ON and OFF retinal ganglion cells
Twyford, P., Cai, C., & Fried, S. I. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/025001 · Cited by 103
Electronic approaches to restoration of sight
Goetz, G., & Palanker, D. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096701 · Cited by 101
Choroidal thickness profiles in retinitis pigmentosa
Ayton, L. N., Guymer, R. H., & Luu, C. D. (2012) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2012.02867.x · Cited by 98
A review and update on the current status of retinal prostheses (bionic eye)
Luo, Y. H.-L., & da Cruz, L. (2014) · British Medical Bulletin · doi:10.1093/bmb/ldu002 · Cited by 89
Activation of ganglion cells and axon bundles using epiretinal electrical stimulation
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskhar, N., Fan, V., Li, P., Hottowy, P., Dabrowski, W., Sher, A., et al. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00750.2016 · Cited by 70
Erickson-Davis, C., & Korzybska, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0229189 · Cited by 83
The Argus™ II retinal prosthesis: Factors affecting patient selection for implantation
Ahuja, A., & Behrend, M. R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.002 · Cited by 82
Self-citationAdvances in auditory prostheses
Shannon, R. V. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834ef878 · Cited by 81
Ong, J. M., & da Cruz, L. (2011) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2011.02590.x · Cited by 79
The brain as a flexible task machine
Reich, L., Maidenbaum, S., & Amedi, A. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834ed723 · Cited by 82
Bionic vision: system architectures – a review
Guenther, T., Lovell, N. H., & Suaning, G. J. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.58 · Cited by 78
Retinitis Pigmentosa: Review of Current Treatment
Wang, A. L., Knight, D. K., Vu, T.-T. T., & Mehta, M. C. (2018) · International Ophthalmology Clinics · doi:10.1097/iio.0000000000000256 · Cited by 73
Encoding visual information in retinal ganglion cells with prosthetic stimulation
Freeman, D. K., Rizzo, J. F., & Fried, S. I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035005 · Cited by 71
Novel interfaces for light directed neuronal stimulation: advances and challenges
Bareket, L., & Hanein, Y. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s51193 · Cited by 74
The Argus® II retinal prosthesis system: An overview
Zhou, D. D., Dorn, J. D., & Greenberg, R. J. (2013) · IEEE International Conference on Multimedia and Expo workshops · doi:10.1109/icmew.2013.6618428 · Cited by 70
Self-citationDagnelie, G. (2011) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32834f02c3 · Cited by 71
Self-citationTherapeutic Challenges to Retinitis Pigmentosa: From Neuroprotection to Gene Therapy
Sahni, J., Angi, M., Irigoyen, C., Angi, M., Semeraro, F., Romano, M., Parmeggiani, F., & Parmeggiani, F. (2011) · Current Genomics · doi:10.2174/138920211795860062 · Cited by 69
Acute electrical stimulation of the human retina with an epiretinal electrode array
Keserü, M., Feucht, M., Bornfeld, N., Laube, T., Walter, P., Rößler, G., Velikay‐Parel, M., Hornig, R., & Richard, G. W. (2011) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2011.02288.x · Cited by 69
Neuroprotective Strategies for the Treatment of Inherited Photoreceptor Degeneration
Trifunović, D., Sahaboglu, A., Kaur, J., Mencl, S., Zrenner, E., Ueffing, M., Arango‐González, B., & Paquet‐Durand, F. (2012) · Current Molecular Medicine · doi:10.2174/156652412800620048 · Cited by 67
Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I
Lan, Y., Falabella, P., Christopher, P., Wuyyuru, V., Dorn, J. D., Schor, P., Greenberg, R. J., Weiland, J. D., & Humayun, M. S. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.08.008 · Cited by 67
Self-citationNaor, O., Hertzberg, Y., Zemel, E., Kimmel, E., & Shoham, S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026006 · Cited by 66
SiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S. R., Cogan, S. F., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T. I., Harris, J. S., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 64
Im, M., & Fried, S. I. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/025002 · Cited by 65
A Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis: Interim Clinical Trial Results
Petoe, M. A., Titchener, S. A., Kolic, M., Kentler, W. G., Abbott, C. J., Nayagam, D. A. X., Baglin, E. K., Kvansakul, J., Barnes, N., Walker, J. G., et al. (2021) · Translational Vision Science & Technology · doi:10.1167/tvst.10.10.12 · Cited by 63
Gu, W., Luo, J., & Liu, J. (2019) · Social Networks · doi:10.1016/j.socnet.2018.11.002 · Cited by 61
Weiss, J. N., & Levy, S. (2018) · Stem Cell Investigation · doi:10.21037/sci.2018.04.02 · Cited by 59
New Vision for Visual Prostheses
Farnum, A., & Pelled, G. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00036 · Cited by 58
Performance of visually guided tasks using simulated prosthetic vision and saliency-based cues
Parikh, N., Itti, L., Humayun, M., & Weiland, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026017 · Cited by 54
Self-citationNau, A. C., Bach, M., & Fisher, C. (2013) · Translational Vision Science & Technology · doi:10.1167/tvst.2.3.1 · Cited by 54
Singer, M. A., Herro, A. M., Probandarwalla, S. S., Pollard, J., Amir, A., Herro, & Singer (2011) · Clinical ophthalmology · doi:10.2147/opth.s15028 · Cited by 51
Animal coloration research: why it matters
Caro, T., Stoddard, M. C., & Stuart-Fox, D. M. (2017) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2016.0333 · Cited by 52
Chang, Y.-C., Ghaffari, D. H., Chow, R. H.-P., & Weiland, J. D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf92b · Cited by 54
Interphase gap as a means to reduce electrical stimulation thresholds for epiretinal prostheses
Weitz, A. C., Behrend, M. R., Ahuja, A., Christopher, P., Wei, J., Wuyyuru, V., Patel, U. K., Greenberg, R. J., Humayun, M. S., Chow, R. H.-P., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016007 · Cited by 51
Self-citationWorldwide Argus II implantation: recommendations to optimize patient outcomes
Ghodasra, D. H., Chen, A., Arévalo, J. F., Birch, D. G., Branham, K. E. H., Coley, B., Dagnelie, G., de Juan, E., Devenyi, R. G., Dorn, J. D., et al. (2016) · BMC Ophthalmology · doi:10.1186/s12886-016-0225-1 · Cited by 50
Self-citationPersonalized therapeutic strategies for patients with retinitis pigmentosa
Zheng, A., Li, Y., & Tsang, S. H. (2015) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2015.1006192 · Cited by 50
A System Verification Platform for High-Density Epiretinal Prostheses
Chen, K., Lo, Y., Yang, Z., Weiland, J. D., Humayun, M. S., & Liu, W. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2200103 · Cited by 48
Self-citationCaspi, A., Roy, A., Wuyyuru, V., Rosendall, P. E., Harper, J. W., Katyal, K. D., Barry, M. P., Dagnelie, G., & Greenberg, R. J. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22377 · Cited by 47
Self-citationThe Retinal Response to Sinusoidal Electrical Stimulation
Twyford, P., & Fried, S. I. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2415811 · Cited by 47
Development of a molecular diagnostic test for Retinitis Pigmentosa in the Japanese population
Maeda, A., Yoshida, A., Kawai, K., Arai, Y., Akiba, R., Inaba, A., Takagi, S. T., Fujiki, R., Hirami, Y., Kurimoto, Y., et al. (2018) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-018-0601-x · Cited by 46
Sabbah, N., Authie, C. N., Sanda, N., Mohand-Said, S., Sahel, J.-A., & Safran, A. B. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15392 · Cited by 45
Brain-Machine Interfaces to Assist the Blind
Ptito, M., Bleau, M., Djerourou, I., Paré, S., Schneider, F. C., & Chebat, D.-R. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.638887 · Cited by 45
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Paraskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39
Luo, Y. H.-L., Zhong, J., & da Cruz, L. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2912-z · Cited by 39
The response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38
Assessment of MRI issues for the Argus II Retinal Prosthesis
Weiland, J. D., Faraji, B., Greenberg, R. J., Humayun, M. S., & Shellock, F. G. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.12.005 · Cited by 38
Self-citationFacial identification in very low-resolution images simulating prosthetic vision
Chang, M. H., Kim, H.-S., Shin, J., & Park, K. S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046012 · Cited by 38
The Argus II prosthesis facilitates reaching and grasping tasks: a case series
Kotecha, A., Zhong, J., Stewart, D., & da Cruz, L. (2014) · BMC Ophthalmology · doi:10.1186/1471-2415-14-71 · Cited by 42
Noninvasive Ultrasound Retinal Stimulation for Vision Restoration at High Spatiotemporal Resolution
Qian, X., Lu, G., Thomas, B. B., Li, R., Chen, X., Shung, K. K., Humayun, M. S., & Zhou, Q. (2022) · BME Frontiers · doi:10.34133/2022/9829316 · Cited by 37
Self-citationBuilding the bionic eye: an emerging reality and opportunity
Merabet, L. B. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53355-5.00001-4 · Cited by 40
Suppression of Subthalamic Nucleus Activity by Micromagnetic Stimulation
Lee, S. W., & Fried, S. I. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2348415 · Cited by 35
Prosthetic vision: devices, patient outcomes and retinal research
Hadjinicolaou, A. E., Hamish Meffin, A., Maturana, M. I., Cloherty, S. L., & Ibbotson, M. R. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12342 · Cited by 38
Rountree, C. M., Raghunathan, A., Troy, J. B., & Saggere, L. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.52 · Cited by 35
Quasi-monopolar electrical stimulation of the retina: a computational modelling study
Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/025002 · Cited by 35
Progress in artificial vision through suprachoroidal retinal implants
Bareket, L., Barriga‐Rivera, A., Zapf, M. P., Lovell, N. H., & Suaning, G. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6cbb · Cited by 36
Opie, N. L., Greferath, U., Vessey, K. A., Burkitt, A. N., Hamish Meffin, A., Grayden, D. B., & Fletcher, E. L. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10600 · Cited by 33
Retinal Prosthetic Approaches to Enhance Visual Perception for Blind Patients
Shim, S., Eom, K., Jeong, J., & Kim, S. J. (2020) · Micromachines · doi:10.3390/mi11050535 · Cited by 35
Model-based analysis of multiple electrode array stimulation for epiretinal visual prostheses
Mueller, J. K., & Grill, W. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036002 · Cited by 32
The argus ii retinal prosthesis system
Bloch, E., & da Cruz, L. (2020) · Prosthesis · doi:10.5772/intechopen.84947 · Cited by 31
Spencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Optical coherence tomography imaging of retinal damage in real time under a stimulus electrode
Cohen, E. D., Agrawal, A., Connors, M., Hansen, B., Charkhkar, H., & Pfefer, J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056017 · Cited by 31
Creating virtual electrodes with 2D current steering
Spencer, T. C., Fallon, J. B., & Shivdasani, M. N. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab1b8 · Cited by 31
Holographic display system for restoration of sight to the blind
Goetz, G. A., Mandel, Y., Manivanh, R. V., Palanker, D., & Čižmár, T. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056021 · Cited by 31
Jalligampala, A., Sekhar, S., Zrenner, E., & Rathbun, D. L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/2/026004 · Cited by 29
Freeman, D. K., Jeng, J. S., Kelly, S. K., Hartveit, E., & Fried, S. I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046005 · Cited by 31
Depth and motion cues with phosphene patterns for prosthetic vision
Perez-Yus, A., Bermudez-Cameo, J., Guerrero, J. J., & Lopez-Nicolas, G. (2017) · 2017 IEEE International Conference on Computer Vision Workshops (ICCVW) · doi:10.1109/iccvw.2017.179 · Cited by 24
Argus II retinal prosthesis system: An update
Rachitskaya, A. V., & Yuan, A. (2016) · Ophthalmic Genetics · doi:10.3109/13816810.2015.1130152 · Cited by 28
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28
3D Diamond Electrode Array for High-Acuity Stimulation in Neural Tissue
Stamp, M. E. M., Tong, W., Ganesan, K., Prawer, S., Ibbotson, M. R., & Garrett, D. J. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b01165 · Cited by 29
Liu, X., Chen, P., Ding, X., Liu, A., Li, P., Sun, C., & Guan, H. (2022) · Annals of Translational Medicine · doi:10.21037/atm-22-2858 · Cited by 33
Extracellular voltage noise probes the interface between retina and silicon chip
Zeitler, R., Fromherz, P., & Zeck, G. M. (2011) · Applied Physics Letters · doi:10.1063/1.3672224 · Cited by 26
Regenerative nanomedicine and the treatment of degenerative retinal diseases
Zarbin, M. A., Montemagno, C. D., Leary, J. F., & Ritch, R. H. (2011) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.167 · Cited by 28
Metadata
- Authors
- Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group
- Affiliations
- Second Sight Medical Products (US)
- Moorfields Eye Hospital (GB)
- Manchester Royal Eye Hospital (GB)
- Doheny Eye Institute (US)
- Corresponding author
- Ahuja, A. K.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2010-09-29
- Volume
- 95
- Issue
- 4
- Pages
- 539-543
- ISSN
- 0007-1161 (ISSN-L)
- PMC
- PMC3345188
- OpenAlex
- W2171460754
- Cited by
- 289
- References
- 19
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 7 · 2023: 8 · 2022: 14 · 2021: 15 · 2020: 17 · 2019: 17 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 20 · 2014: 27 · 2013: 27 · 2012: 26
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- UCL Discovery (University College London) (submittedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- National Eye Institute (R01EY012893, 5R01EY12893)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- Argus II retinal prosthesis, retinal prosthesis, visual prosthesis, visual augmentation, blind subjects, residual vision, visual acuity, task accuracy
- MeSH terms
- Adult, Aged, Aged, 80 and over, Blindness, Female, Humans, Male, Middle Aged, Motor Activity, Orientation, Prosthesis Design, Retina, Task Performance and Analysis, Touch, Treatment Outcome, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review