Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Objective: The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher. Methods: We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated. Results: 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise—the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively. Conclusions: None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
Sund‐Levander, M., Forsberg, C., & Wahren, L. K. (2002) · Scandinavian Journal of Caring Sciences · doi:10.1046/j.1471-6712.2002.00069.x · Cited by 509
Infrared ear thermometry compared with rectal thermometry in children: a systematic review
Craig, J. V., Lancaster, G. A., Taylor, S., Williamson, P. R., & Smyth, R. L. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09783-0 · Cited by 338
Implementation and Refinement of the Emergency Severity Index
Wuerz, R. C., Travers, D., Gilboy, N., Eitel, D. R., Rosenau, A., & Yazhari, R. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb01283.x · Cited by 257
Accuracy of Noninvasive Core Temperature Measurement in Acutely Ill Adults: The State of the Science
Hooper, V. D., & Andrews, J. O. (2006) · Biological Research For Nursing · doi:10.1177/1099800406289151 · Cited by 141
A comparison of five methods of temperature measurement in febrile intensive care patients
Schmitz, T., Bair, N., Falk, M., & Levine, C. (1995) · American Journal of Critical Care · doi:10.4037/ajcc1995.4.4.286 · Cited by 117
Insufficiency in a New Temporal-Artery Thermometer for Adult and Pediatric Patients
Suleman, M.-I., Doufas, A. G., Akça, O., Ducharme, M., & Sessler, D. I. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200207000-00012 · Cited by 107
Accuracy of infrared ear thermometry in adult patients
Stavem, K., Saxholm, H., & Smith-Erichsen, N. (1997) · Intensive Care Medicine · doi:10.1007/s001340050297 · Cited by 99
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90
Jensen, B. N. (2000) · The European Journal of Surgery · doi:10.1080/110241500447218 · Cited by 80
Core temperature measurement in adults: a literature review
Fulbrook, P. (1993) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.1993.18091451.x · Cited by 76
Rotello, L. C., Crawford, L., & Terndrup, T. E. (1996) · Critical Care Medicine · doi:10.1097/00003246-199609000-00012 · Cited by 72
Comparison of the Temporal Artery and Rectal Thermometry in Children in the Emergency Department
Schuh, S., Komar, L., Stephens, D., Chu, L., Read, S., & Allen, U. (2004) · Pediatric Emergency Care · doi:10.1097/01.pec.0000144915.78124.26 · Cited by 60
The Accuracy of Mother's Touch to Detect Fever in Children: A Systematic Review
Teng, C. L., Ng, C. J., Hanafi, N. S., Zailinawati, A. H., & Tong, S. F. (2007) · Journal of Tropical Pediatrics · doi:10.1093/tropej/fmm077 · Cited by 36
Barnett, B. H., Nunberg, S., Tai, J. Y., LESSER, M. L., Fridman, V., Nichols, P., Powell, R., & Silverman, R. A. (2011) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2011.2.1963 · Cited by 36
A comparison of technologies used for estimation of body temperature
Mangat, J., Standley, T. D. A., Prevost, A. T., Vasconcelos, J. C., & White, P. A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/003 · Cited by 33
Evaluation of Temporal Artery Thermometry in Children 3–36 Months Old
Holzhauer, J., Reith, V., Sawin, K. J., & Yen, K. (2009) · Journal for Specialists in Pediatric Nursing · doi:10.1111/j.1744-6155.2009.00204.x · Cited by 30
Al-Mukhaizeem, F., Allen, U., Komar, L., Naser, B., Roy, L., Stephens, D., Read, S., Kim, C., & Schuh, S. (2004) · Paediatrics & Child Health · doi:10.1093/pch/9.7.461 · Cited by 28
Is the temporal artery thermometer a reliable instrument for detecting fever in children?
Penning, C., van der Linden, J. H., Tibboel, D., & Evenhuis, H. M. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03568.x · Cited by 19
What's hot and what's not: the gold standard for thermometry in emergency medicine.
Jaffe, D. M. (1995) · PubMed · Cited by 19
Tympanic Membrane Versus Temporal Artery Temperatures of Adult Perianesthesia Patients
Fetzer, S. J., & Lawrence, A. (2008) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2008.01.010 · Cited by 17
O’Brien, D., Rogers, I. R., Holden, W., Jacobs, I. G., Mellett, S., Wall, E. J., & DAVIES, D. G. L. (2000) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2000.tb02101.x · Cited by 16
Temperature Measurement in the Phase I PACU
Stanhope, N. (2006) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2005.11.004 · Cited by 14
[Infrared temporal thermometry].
Dybwik, K., & Nielsen, E. W. (2003) · Tidsskrift for Den Norske Laegeforening · Cited by 10
Cited by
Aw, J. (2020) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.02.010 · Cited by 60
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“rectal, pulmonary artery, urinary bladder, and oesophageal sites) [12, 13].”
Serotonin syndrome: a clinical review of current controversies
Werneke, U., Truedson, P., Wikström, H., & Ott, M. (2020) · Journal of Integrative Neuroscience · doi:10.31083/j.jin.2020.04.314 · Cited by 45
Mah, A. J., Zadeh, L. G., Tehrani, M. K., Askari, S., Gandjbakhche, A., & Shadgan, B. (2021) · Biology · doi:10.3390/biology10121327 · Cited by 45
A body bag can save your life: a novel method of cold water immersion for heat stroke treatment
Kim, D. A., Lindquist, B., Shen, S. H., Wagner, A. M., & Lipman, G. S. (2020) · Journal of the American College of Emergency Physicians Open · doi:10.1002/emp2.12007 · Cited by 28
Metadata
- Authors
- Bijur, P. E., Shah, P. D., & Esses, D.
- Affiliations
- Albert Einstein College of Medicine (US)
- Corresponding author
- Bijur, Polly E
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2016-06-22
- Volume
- 33
- Issue
- 12
- Pages
- 843-847
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W2470356317
- Semantic Scholar
- 480bfe7d3d218cf0ae9f674a651904875e1f36a5
- Cited by
- 55
- References
- 26
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 7 · 2020: 11 · 2019: 2 · 2018: 3 · 2017: 1
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Emergency Medicine Journal (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Keywords
- body temperature measurement, fever detection, oral temperature, tympanic temperature, rectal temperature, diagnostic accuracy, sensitivity and specificity, non-invasive temperature measurement, emergency department patients
- MeSH terms
- Body Temperature, Cross-Sectional Studies, Emergency Service, Hospital, Female, Fever, Humans, Male, Middle Aged, Rectum, Sensitivity and Specificity, Temporal Arteries, Triage, Tympanic Membrane, Benchmarking, Thermometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.