Diagnostic accuracy of the magnetocardiograph for patients with suspected acute coronary syndrome
Open accessThe DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Abstract
BACKGROUND: We aimed to estimate the diagnostic accuracy of the VitalScan magnetocardiograph (MCG) for suspected acute coronary syndrome (ACS). METHODS: We undertook a prospective cohort study evaluating the diagnostic accuracy of the MCG in adults with suspected ACS. The reference standard of ACS was determined by an independent adjudication committee based on 30-day investigations and events. The cohort was split into a training sample, to derive the MCG algorithm and an algorithm combining MCG with a modified Manchester Acute Coronary Syndrome (MACS) clinical probability score, and a validation sample, to estimate diagnostic accuracy. RESULTS: We recruited 756 participants and analysed data from 680 (293 training, 387 validation), of whom 96 (14%) had ACS. In the training sample, the respective area under the receiver operating characteristic (AUROC) curves were the following: MCG 0.66 (95% CI 0.58 to 0.74), MACS 0.64 (95% CI 0.54 to 0.73) and MCG+MACS 0.70 (95% CI 0.63 to 0.77). MCG specificity was 0.16 (95% CI 0.12 to 0.21) at the threshold achieving acceptable sensitivity for rule-out (>0.98). In the validation sample (n=387), the respective AUROCs were the following: MCG 0.56 (95% CI 0.48 to 0.64), MACS 0.69 (95% CI 0.61 to 0.77) and MCG+MACS 0.64 (95% CI 0.56 to 0.72). MCG sensitivity was 0.89 (95% CI 0.77 to 0.95) and specificity 0.15 (95% CI 0.12 to 0.20) at the rule-out threshold. MCG+MACS sensitivity was 0.85 (95% CI 0.73 to 0.92) and specificity 0.30 (95% CI 0.25 to 0.35). CONCLUSION: The VitalScan MCG is currently unable to accurately rule out ACS and is not yet ready for use in clinical practice. Further developmental research is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“concluded that, at least in 2020, the VitalScan did not yet meet the level of accuracy required to confidently rule out ACS in the ED clinical practice (263).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [263]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., Thygesen, K., Alpert, J. S., White, H. D., Jaffe, A. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.001 · Cited by 2,621
Third universal definition of myocardial infarction
the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.122 · Cited by 2,053
The health care burden of acute chest pain: Figure 1
Goodacre, S., Cross, E., Arnold, J., Angelini, K., Capewell, S., & Nicholl, J. (2005) · Heart · doi:10.1136/hrt.2003.027599 · Cited by 486
Self-citationGoodacre, S. W., Bradburn, M., Cross, E., Collinson, P., Gray, A., & Hall, A. S. (2011) · Heart · doi:10.1136/hrt.2010.203166 · Cited by 151
Self-citationMagnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109
Body, R. M., Carley, S. D., McDowell, G., Pemberton, P. W., Burrows, G., Cook, G., Lewis, P., Smith, A., & Mackway-Jones, K. C. (2014) · Heart · doi:10.1136/heartjnl-2014-305564 · Cited by 92
Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78
Lim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52
Kwon, H., Kim, K., Lee, Y.-H., Kim, J.-M., Yu, K. K., Chung, N., & Ko, Y.-G. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0975 · Cited by 47
A portable diagnostic device for cardiac magnetic field mapping
Mooney, J. W., Ghasemi-Roudsari, S., Banham, E. R., Symonds, C., Pawlowski, N., & Varcoe, B. T. H. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/3/1/015008 · Cited by 39
Can magnetocardiography detect patients with non‐ST‐segment elevation myocardial infarction?
Lim, H. K., Chung, N., Kim, K., Ko, Y., Kwon, H., Lee, Y., Kim, J., Joung, B., Kim, J., Yu, K. K., et al. (2007) · Annals of Medicine · doi:10.1080/07853890701538040 · Cited by 38
Park, J.-W., & Jung, F. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.050 · Cited by 37
Müller, H.-P., Gödde, P., Czerski, K., Oeff, M., Agrawal, R., ENDT, P., Kruse, W., Steinhoff, U., & Trahms, L. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/1/009 · Cited by 32
Goernig, M., Liehr, M., Tute, C., Schlosser, M., Haueisen, J., Figulla, H. R., & LEDER, U. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9598-5 · Cited by 25
Ghasemi-Roudsari, S., Al-Shimary, A., Varcoe, B., Byrom, R., Kearney, L., & Kearney, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191241 · Cited by 19
Cross, E., & Goodacre, S. W. (2010) · Emergency Medicine Journal · doi:10.1136/emj.2009.086298 · Cited by 15
Self-citationExternal Validation of the Manchester Acute Coronary Syndromes Decision Rule
Carlton, E. W., Body, R. M., & Greaves, K. (2016) · Academic Emergency Medicine · doi:10.1111/acem.12860 · Cited by 13
Self-citationMagnetocardiography in patients with acute chest pain and bundle branch block
Leithäuser, B., Park, J.-W., Hill, P., Lam, Y.-Y., & Jung, F. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.254 · Cited by 10
Research works printed but not linked: 1
- 7. Lin LJ, Tang FK, Hua N et al. Contrast between magnetocardiography and electrocardiography for the early diagnosis of coronary artery disease in patients with acute chest pain. In Computing in Cardiology (2007), IEEE Computer Society, Hangzhou, China: 641-43.
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 68
“1 ms Anatomic CAD/Patients with stable angina and CAD (55)/Shielded 64-channel Rest 68%/86% (0.”
BackgroundMethodRoth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Assessing heart disease using a novel magnetocardiography device
Beadle, R., McDonnell, D., Ghasemi-Roudsari, S., Unitt, L., Parker, S. J., & Varcoe, B. T. H. (2021) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/abe5c5 · Cited by 18
Self-citationAdvances of magnetocardiography in application of adult and fetal cardiac diseases
Li, J., Shen, Y., Shen, C., Ning, X., & Xiang, M. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1522467 · Cited by 16
Metadata
- Authors
- Goodacre, S., Walters, S. J., Qayyum, H., Coffey, F., Carlton, E., Coats, T., Glazebrook, W., & Unitt, L.
- Affiliations
- University of Sheffield (GB)
- Sheffield Teaching Hospitals NHS Foundation Trust (GB)
- Nottingham University Hospitals NHS Trust (GB)
- North Bristol NHS Trust (GB)
- St George's Hospital (GB)
- Creavo (United Kingdom) (GB)
- Corresponding author
- Goodacre, Steve
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2020-10-13
- Volume
- 38
- Issue
- 1
- Pages
- 47-52
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W3092649762
- Cited by
- 13
- References
- 20
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by-nc
- Locations
- Emergency Medicine Journal (publishedVersion)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Figshare (submittedVersion, cc-by-nc)
- Funders
- Creavo Medical Technologies (None)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- magnetocardiography, acute coronary syndrome, diagnostic accuracy, rule-out, sensitivity and specificity, noninvasive cardiac assessment
- MeSH terms
- Adult, Aged, Algorithms, Diagnosis, Differential, Female, Humans, Male, Middle Aged, Prospective Studies, Sensitivity and Specificity, Magnetocardiography, Acute Coronary Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.