Chronic pacing and adverse outcomes after transcatheter aortic valve implantation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective: Many patients undergoing transcatheter aortic valve implantation (TAVI) have a pre-existing, permanent pacemaker (PPM) or receive one as a consequence of the procedure. We hypothesised that chronic pacing may have adverse effects on TAVI outcomes. Methods and results: Four groups of patients undergoing TAVI in the Placement of Aortic Transcatheter Valves (PARTNER) trial and registries were compared: prior PPM (n=586), new PPM (n=173), no PPM (n=1612), and left bundle branch block (LBBB)/no PPM (n=160). At 1 year, prior PPM, new PPM and LBBB/no PPM had higher all-cause mortality than no PPM (27.4%, 26.3%, 27.7% and 20.0%, p<0.05), and prior PPM or new PPM had higher rehospitalisation or mortality/rehospitalisation (p<0.04). By Cox regression analysis, new PPM (HR 1.38, 1.00 to 1.89, p=0.05) and prior PPM (HR 1.31, 1.08 to 1.60, p=0.006) were independently associated with 1-year mortality. Surviving prior PPM, new PPM and LBBB/no PPM patients had lower LVEF at 1 year relative to no PPM (50.5%, 55.4%, 48.9% and 57.6%, p<0.01). Prior PPM had worsened recovery of LVEF after TAVI (Δ=10.0 prior vs 19.7% no PPM for baseline LVEF <35%, p<0.0001; Δ=4.1 prior vs 7.4% no PPM for baseline LVEF 35–50%, p=0.006). Paced ECGs displayed a high prevalence of RV pacing (>88%). Conclusions: In the PARTNER trial, prior PPM, along with new PPM and chronic LBBB patients, had worsened clinical and echocardiographic outcomes relative to no PPM patients, and the presence of a PPM was independently associated with 1-year mortality. Ventricular dyssynchrony due to chronic RV pacing may be mechanistically responsible for these findings. Trial registration number: (ClinicalTrials.gov NCT00530894).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationThe DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Research works printed but not linked: 23
- 10.1016/j.jacc.2012.11.050 · DOI · Paper page
- 10.1111/j.1540-8167.2011.02211.x · DOI · Paper page
- 10.7326/0003-4819-158-1-201301010-00007 · DOI · Paper page
- Jilaihawi, 2012, Meta-analysis of complications in aortic valve replacement: comparison of Medtronic-Corevalve, Edwards-Sapien and surgical aortic valve replacement in 8,536 patients, CatheterCardiovasc Interv, 80, 128
- 10.1016/j.jacc.2014.04.033 · DOI · Paper page
- 10.1016/j.pcad.2008.01.001 · DOI
- 10.1056/NEJMoa1210356 · DOI · Paper page
- 10.1093/eurheartj/eht376 · DOI · Paper page
- 10.1161/CIRCULATIONAHA.113.005479 · DOI · Paper page
- 10.1016/j.jcin.2012.08.011 · DOI
- 10.1016/j.echo.2013.01.013 · DOI
- 10.1161/CIRCULATIONAHA.105.608356 · DOI · Paper page
- 10.1016/j.hrthm.2013.12.020 · doi:10.1016/j.hrthm.2013.12.020
- 10.1161/CIRCULATIONAHA.112.101055 · DOI · Paper page
- 10.1161/CIRCULATIONAHA.112.001099 · DOI · Paper page
- Urena, 2014, Impact of new onset persistent left bundle branch block on late clinical outcomes in patients undergoing transcatheter aortic valve implantation with a balloon expandable valve, JACC Cardiovasc Interv, 7, 128, 10.1016/j.jcin.2013.08.015 · DOI · Paper page
- Nazif, 2015, Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacment: The PARTNER (Placement of Aortic Transcatheter Valves) trial and registry, J Am Coll Cardiol Intv, 8, 60, 10.1016/j.jcin.2014.07.022 · DOI · Paper page
- 10.1016/j.ijcard.2012.11.115 · DOI
- 10.1016/j.amjcard.2013.07.022 · doi:10.1016/j.amjcard.2013.07.022
- 10.1056/NEJMoa013040 · DOI · Paper page
- 10.1016/j.jacc.2012.03.054 · DOI · Paper page
- 10.7326/0003-4819-142-12_Part_1-200506210-00006 · DOI
- 10.1161/CIRCULATIONAHA.106.655712 · DOI
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
VARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Metadata
- Authors
- Dizon, J. M., Nazif, T. M., Hess, P. L., Biviano, A., Garan, H., Douglas, P. S., Kapadia, S., Babaliaros, V., Herrmann, H. C., Szeto, W. Y., Jilaihawi, H., Fearon, W. F., Tuzcu, E. M., Pichard, A. D., Makkar, R., Williams, M., Hahn, R. T., Xu, K., Smith, C. R., Leon, M. B., & Kodali, S. K.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2015-08-10
- Volume
- 101
- Issue
- 20
- Pages
- 1665-1671
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W1951884286
- Cited by
- 130
- References
- 4
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic pacing and adverse outcomes after transcatheter aortic valve implantation. https://app.cochat.ai/papers/10.1136/heartjnl-2015-307666
- The paper
- Dizon, J. M., Nazif, T. M., Hess, P. L., Biviano, A., Garan, H., Douglas, P. S., Kapadia, S., Babaliaros, V., Herrmann, H. C., Szeto, W. Y., Jilaihawi, H., Fearon, W. F., Tuzcu, E. M., Pichard, A. D., Makkar, R., Williams, M., Hahn, R. T., Xu, K., Smith, C. R., . . . Kodali, S. K. (2015). Chronic pacing and adverse outcomes after transcatheter aortic valve implantation. Heart. https://doi.org/10.1136/heartjnl-2015-307666
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.